hrcak mascot   Srce   HID

Other
https://doi.org/10.20471/acc.2019.58.04.25

Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report

Katia Novak-Lauš ; Department of Ophthalmology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia
Lana Knežević ; Department of Ophthalmology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia
Goran Marić ; Department of Ophthalmology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia
Mia Zorić Geber ; Department of Ophthalmology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia
Zoran Vatavuk ; Department of Ophthalmology, Sestre milosrdnice University Hospital Centre, Zagreb, Croatia

Fulltext: english, pdf (324 KB) pages 767-769 downloads: 221* cite
APA 6th Edition
Novak-Lauš, K., Knežević, L., Marić, G., Zorić Geber, M. & Vatavuk, Z. (2019). Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report. Acta clinica Croatica, 58. (4.), 767-769. https://doi.org/10.20471/acc.2019.58.04.25
MLA 8th Edition
Novak-Lauš, Katia, et al. "Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report." Acta clinica Croatica, vol. 58., no. 4., 2019, pp. 767-769. https://doi.org/10.20471/acc.2019.58.04.25. Accessed 23 Sep. 2021.
Chicago 17th Edition
Novak-Lauš, Katia, Lana Knežević, Goran Marić, Mia Zorić Geber and Zoran Vatavuk. "Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report." Acta clinica Croatica 58., no. 4. (2019): 767-769. https://doi.org/10.20471/acc.2019.58.04.25
Harvard
Novak-Lauš, K., et al. (2019). 'Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report', Acta clinica Croatica, 58.(4.), pp. 767-769. https://doi.org/10.20471/acc.2019.58.04.25
Vancouver
Novak-Lauš K, Knežević L, Marić G, Zorić Geber M, Vatavuk Z. Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report. Acta clinica Croatica [Internet]. 2019 [cited 2021 September 23];58.(4.):767-769. https://doi.org/10.20471/acc.2019.58.04.25
IEEE
K. Novak-Lauš, L. Knežević, G. Marić, M. Zorić Geber and Z. Vatavuk, "Subconjunctival Fragmentation of a Previously Efficient XEN Gel Stent Implantation and Successful Bleb Formation: a Case Report", Acta clinica Croatica, vol.58., no. 4., pp. 767-769, 2019. [Online]. https://doi.org/10.20471/acc.2019.58.04.25

Abstracts
The XEN gel stent is one of the available minimally invasive glaucoma surgery devices, a new generation implant, which is designed to reduce intraocular pressure in patients with primary open angle glaucoma if past medical treatments have failed. This report presents a case of subconjunctival fragmentation of the XEN gel stent after a three-month follow-up of successful XEN gel implantation. A 70-year-old male patient was treated for primary open angle glaucoma. He underwent successful phacoemulsification and intraocular lens implantation two years before. Due to medical therapy failure in controlling glaucoma, XEN gel stent implantation was suggested to the patient. The implant was successfully placed in both eyes, and extended bleb and drainage aqueous humor from the anterior chamber to the subconjunctival space was obtained. Three months after the surgery, at a regular follow-up visit, three fragments of the subconjunctival part of the XEN gel implant were
found in his left eye. Neither serious complications nor intraocular pressure increase were detected. A new potential complication of the XEN gel implant is described.

Keywords
Intraocular pressure; Glaucoma, open-angle; Lens implantation, intraocular; Stents; Minimally invasive surgical procedures; Filtering surgery