<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD with MathML3 v1.1 20151215//EN " "JATS-journalpublishing1-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.1" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="doi">10.33004</journal-id>
      <journal-title-group>
        <journal-title xml:lang="en">Reumatizam</journal-title>
        <abbrev-journal-title>Reumatizam (1964)</abbrev-journal-title>
      </journal-title-group>
      <issn pub-type="ppub">0374-1338</issn>
      <issn pub-type="epub">2459-6159</issn>
      <publisher>
        <publisher-name xml:lang="hr">Hrvatsko reumatološko društvo HLZ-a</publisher-name>
        <publisher-name xml:lang="en">Croatian Society for Rheumatology of the CMA</publisher-name>
        <publisher-loc>
          <addr-line>Šubićeva 9, Zagreb</addr-line>
          <email xlink:href="izdavac@reumatizam.org">izdavac@reumatizam.org</email>
          <ext-link ext-link-type="uri" xlink:href="http://www.reumatologija.org">http://www.reumatologija.org</ext-link>
        </publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.33004/reumatizam-67-2-7</article-id>
      <article-categories>
        <subj-group subj-group-type="heading" xml:lang="hr">
          <subject>Izvorni znanstveni članak</subject>
        </subj-group>
        <subj-group subj-group-type="heading" xml:lang="en">
          <subject>Original scientific paper</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="hr">Novi parametri stiska šake u bolesnika s reumatoidnim artritisom temeljeni na elektrodinamičkim mjerenjima – pilot evaluacijska studija</article-title>
        <trans-title-group>
          <trans-title xml:lang="en">New parameters of hand grip in rheumatoid arthritis patients based on electrodynamic measurements – a pilot evaluation study</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Doko Vajdić</surname>
            <given-names>Ines</given-names>
          </name>
          <email xlink:href="inesdoko@yahoo.com">inesdoko@yahoo.com</email>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Dubravić</surname>
            <given-names>Amir</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Michieli</surname>
            <given-names>Ivan</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Medved Rogina</surname>
            <given-names>Branka</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Grazio</surname>
            <given-names>Simeon</given-names>
          </name>
        </contrib>
        <aff id="aff1">
          <institution xml:lang="hr">Klinika za reumatologiju, fizikalnu medicinu i rehabilitaciju Kliničkoga bolničkog centra Sestre milosrdnice, Medicinski fakultet u Zagrebu, Zagreb, Hrvatska</institution>
          <institution xml:lang="en">1University Department of Rheumatology, Physical and Rehabilitation Medicine, Sestre Milosrdnice University Hospital Center, School of Medicine, Zagreb, Croatia</institution>
        </aff>
        <aff id="aff2">
          <institution xml:lang="hr">Institut Ruđer Bošković, Zagreb, Hrvatska</institution>
          <institution xml:lang="en">Ruđer Bošković Institute, Zagreb, Croatia</institution>
        </aff>
        <aff id="aff3">
          <institution xml:lang="hr">Institut Ruđer Bošković, Zagreb, Hrvatska</institution>
          <institution xml:lang="en">Ruđer Bošković Institute, Zagreb, Croatia</institution>
        </aff>
        <aff id="aff4">
          <institution xml:lang="hr">Ruđer Bošković Institute, Zagreb, Croatia</institution>
          <institution xml:lang="en">Ruđer Bošković Institute, Zagreb, Croatia</institution>
        </aff>
        <aff id="aff5">
          <institution xml:lang="hr">Klinika za reumatologiju, fizikalnu medicinu i rehabilitaciju Kliničkoga bolničkog centra Sestre milosrdnice, Medicinski fakultet u Zagrebu, Zagreb, Hrvatska</institution>
          <institution xml:lang="en">1University Department of Rheumatology, Physical and Rehabilitation Medicine, Sestre Milosrdnice University Hospital Center, School of Medicine, Zagreb, Croatia</institution>
        </aff>
      </contrib-group>
      <pub-date>
        <day>14</day>
        <month>09</month>
        <year>2021</year>
      </pub-date>
      <volume>67</volume>
      <fpage>78</fpage>
      <lpage>82</lpage>
      <permissions>
        <license license-type="open-access" xlink:href="">
          <license-p>CC BY-NC-ND (Attribution, Non Commercial, No Derivs)</license-p>
        </license>
        <license license-type="open-access" xml:lang="hr">
          <license-p>Reumatizam časopis je otvorenog pristupa (engl. open access – OA), što znači slobodan, besplatan i neometan mrežni pristup digitalnim stručnim i znanstvenim radovima. Reumatizam bjavljuje radove bez naknade, uz licencu Creative Commons Attribution-  NonCommercial-NoDerivatives 4.0 International. Svi su članci slobodno dostupni pod uvjetima te licence, koja dopušta preuzimanje i dijeljenje radova uz obvezno navođenje izvora, ali ne dopušta njihovu izmjenu niti komercijalnu uporabu (https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode).&#13;
Licence Creative Commons pravni su instrumenti kojima se autorima i drugim nositeljima prava (davateljima licence, u ovom slučaju Liječnički vjesnik) omogućuje da odrede uvjete korištenja svojih autorskih djela, uključujući umnožavanje, distribuciju i objavljivanje.&#13;
Sadržaj časopisa Reumatizam smije se bez naknade koristiti u nastavne i istraživačke svrhe, uz obvezno navođenje izvora.</license-p>
        </license>
        <license license-type="open-access" xml:lang="en">
          <license-p>Rheumatism is an open access (OA) journal, which means free, unrestricted online access to digital professional and scientific publication. Reumatisa publishes papers free of charge under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International license. All articles are freely available under the terms of this license, which permits downloading and sharing of the works with proper attribution, but does not allow modification or commercial use (https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode).&#13;
Creative Commons licenses are legal tools that enable authors and other rights holders (licensors, in this case Liječnički vjesnik) to define the conditions under which their works may be used, including reproduction, distribution, and publication.&#13;
The content of Reumatism may be used free of charge for educational and research purposes, provided that the source is properly acknowledged.</license-p>
        </license>
      </permissions>
      <abstract xml:lang="hr">
        <p>Uvod: U reumatoidnom artritisu upala i oštećenje dovode do funkcionalne nesposobnosti. Uobičajeno mjesto zahvaćenosti jest šaka i zato ovi bolesnici često imaju slabiju snagu stiska. U bolesnika s reumatoidnim artritisom potrebno je provesti detaljniju evaluaciju oštećenja šake. Cilj ove studije bila je analiza nove metode mjerenja snage stiska šake. Metode: Razvijen je ekspertni elektronički mjerni sustav za dobivanje dinamičkih vremenskih serija sile stiska šake. Testirali smo ga na uzorku od 24 sudionika: 12 bolesnika s reumatoidnim artritisom i 12 zdravih kontrolnih ispitanika koji se podudaraju po dobi i spolu. Glavni dobiveni dinamometrijski parametri bili su: maksimalna sila stiska šake, zamor šake, brzina stiska te funkcionalni potencijal. Navedeni parametri izmjereni su pri početnomu mjerenju i nakon 60, 120 i 180 dana. Rezultati: U usporedbi s kontrolnom skupinom bolesnici s reumatoidnim artritisom imali su znatno manju maksimalnu silu stiska šake (68,2 prema 97,3), raniju pojavu zamora šake (22,4 prema 24,9), manju brzinu stiska (14,8&#13;
prema 22,2) i manji funkcionalni potencijal (808,2 prema 1876,3) pri početnomu mjerenju. Tijekom praćenja primijećeno je znatno poboljšanje svih izmjerenih varijabla. Zaključak: U našoj pilot studiji testirali smo novorazvijeni elektrodinamometrijski sustav mjerenja te smo utvrdili da se njegovom uporabom može objektivno i detaljno opisati stanje šake. Taj se sustav može upotrijebiti kao relevantan pokazatelj funkcije šake u bolesnika s reumatoidnim artritisom i može pomoći u prilagodbi njihove rehabilitacije.</p>
      </abstract>
      <trans-abstract xml:lang="en">
        <p>Introduction: In rheumatoid arthritis, inflammation and damage lead to functional impairment. As the hand is a typical site of involvement, lower grip strength is often found in patients with rheumatoid arthritis. In these patients it is necessary to evaluate the hand grip impairment in a more detailed way. The aim of this study was to analyze a new method for measuring hand grip. Methods: An expert electronic measuring system for obtaining dynamic time series of hand grip force was developed. We tested it in a sample of 24 participants, 12 patients with rheumatoid arthritis and 12 age- and sex- matched healthy controls. The main dynamometric parameters obtained were: maximum grip force, fatigue, grip velocity, and&#13;
functional potential. These were measured at the baseline and at 60, 120, and 180 days. Results: Compared to the control group, at baseline the patients with rheumatoid arthritis had a significantly lower maximum grip force (68.2 vs. 97.3), earlier occurrence of fatigue (22.4 vs. 24.9), as well as lower grip velocity (14.8 vs. 22.2) and functional potential (808.2 vs. 1876.3). A significant improvement in all measured variables was observed during the follow-up period. Conclusion: In our pilot study we tested a newly developed electrodynamometer measuring system and found that it can provide an objective and detailed description of the hand condition. This system has the potential to be used as a relevant indicator of hand function in patients with rheumatoid arthritis as well as to help tailor their rehabilitation.</p>
      </trans-abstract>
      <kwd-group xml:lang="hr">
        <kwd>Reumatoidni artritis – patofiziologija, rehabilitacija</kwd>
        <kwd>Šaka – patofiziologija</kwd>
        <kwd>Snaga šake</kwd>
        <kwd>Dinamometar za mišićnu snagu</kwd>
        <kwd>Pilot istraživanja</kwd>
      </kwd-group>
      <kwd-group xml:lang="en">
        <kwd>Arthritis, rheumatoid – physiopathology, rehabilitation</kwd>
        <kwd>Hand – physiopatholoy</kwd>
        <kwd>Hand strength</kwd>
        <kwd>Muscle strength dynamometer</kwd>
        <kwd>Pilot projects</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <p><bold>Introduction:</bold> In rheumatoid arthritis, inflammation and damage lead to functional impairment. As the hand is a typical site of involvement, lower grip strength is often found in patients with rheumatoid arthritis. In these patients it is necessary to evaluate the hand grip impairment in a more detailed way. The aim of this study was to analyze a new method for measuring hand grip.</p>
    <p><bold>Methods:</bold> An expert electronic measuring system for obtaining dynamic time series of hand grip force was developed. We tested it in a sample of 24 participants, 12 patients with rheumatoid arthritis and 12 age- and sex-matched healthy controls. The main dynamometric parameters obtained were: maximum grip force, fatigue, grip velocity, and functional potential. These were measured at the baseline and at 60, 120, and 180 days.</p>
    <p><bold>Results:</bold> Compared to the control group, at baseline the patients with rheumatoid arthritis had a significantly lower maximum grip force (68.2 vs. 97.3), earlier occurrence of fatigue (22.4 vs. 24.9), as well as lower grip velocity (14.8 vs. 22.2) and functional potential (808.2 vs. 1876.3). A significant improvement in all measured variables was observed during the follow-up period.</p>
    <p><bold>Conclusion:</bold> In our pilot study we tested a newly developed electrodynamometer measuring system and found that it can provide an objective and detailed description of the hand condition. This system has the potential to be used as a relevant indicator of hand function in patients with rheumatoid arthritis as well as to help tailor their rehabilitation.</p>
    <p>Key words: Arthritis, rheumatoid – physiopathology, rehabilitation; Hand – physiopatholoy; Hand strength; Muscle strength dynamometer; Pilot projects</p>
    <sec>
      <title>INTRODUCTION</title>
      <p>Polyarthritis of the hand is a hallmark of rheumatoid arthritis (RA). Standard hand dynamometry registration of one-grip force or the recording of a series of multiple grips are commonly used to evaluate the function of the hand (<italic>1</italic>, <italic>2</italic>). This provides an approximate measurement of handgrip strength, but not a detailed insight (<italic>3</italic>). A more detailed assessment would be useful for tailored rehabilitation of the hand in patients with RA, but also in patients with other non-rheumatic conditions involving the hand. Therefore, we developed a custom-designed electronic dynamic sensor in order to measure different minutely specified parameters for handgrip evaluation. The aim of this pilot study was to evaluate the hand grip in patients with RA using this new electrodynamic method.</p>
    </sec>
    <sec>
      <title>METHOD</title>
      <p>This pilot study included 24 subjects, 12 patients with RA (6 women and 6 men, aged 35–55 years) in the early phase of the disease, and 12 healthy sex- and age-matched controls. The patients with RA were enrolled consecutively from the outpatient clinic according to the following inclusion criteria: newly diagnosed RA with disease duration &lt; 6 months, age 35–55 years, and treatment with orally taken methotrexate 15 mg/week. In the evaluation of motor hand function a new expert electronic measuring system for dynamic measurements of the hand grip force, developed at the Ruđer Bošković Institute, was used (Figure 1). The device was calibrated in accordance with hand grip comparison on a mechanical dynamometric device with the same mechanical handrail. The dynamics of the dynamometric hand grip parameters in both groups was measured at the baseline and after 60, 120, and 180 days. All the patients were treated with the anchor disease-modifying anti-rheumatic drug (DMARD) methotrexate, and during the follow-up period its dosage was not changed. The patients had the option of taking NSAIDs and/or acetaminophen as an escape medication, but were required to stop the medication three days before each visit. The main dynamometric parameters of interest obtained were: maximum grip force (highest achieved power of each grip), fatigue (onset of decreasing tendency in maximum grip force in the grip series), grip velocity (ratio of maximum force and time in which the individual grip is achieved), and functional potential (composite measure combining the average grip force, average grip velocity, and fatigue). The evaluation of the hand’s functional deficit was performed by registering and extracting previously defined parameters in time and spectral domain over the processed time grip series of the dominant hand. The described pre-processing was conducted over a grip series (15 times) at baseline (moment t = 0) and at visits every two months thereafter. In order to minimize fluctuation and amplitude effects, Fourier analysis was used for each cycle. The best 10 from a total of 15 individual cycles were selected for each study participant, and the most irregular cycles, such as those containing more irregular maximums, uneven grip phase, or delay at the beginning and at the end of each grip, were removed. Statistical analysis included the T-test and the ANOVA test for repeated measures.</p>
    </sec>
    <sec>
      <title>RESULTS</title>
      <p>The two groups were well matched to age, and no significant difference was found between them (the mean and SD for age in RA patients was 54.7 ± 8.2 years, and in healthy controls 54.2 ± 8.2; P = 0.883). The baseline data on the dynamometric parameters of interest in the patients with RA and healthy controls are shown in Table 1. Compared to the control group, the RA patients had a significantly lower maximum grip force, fatigue (earlier occurrence of fatigue), grip velocity, and functional potential.</p>
      <p>During the follow-up period, the measured dynamometric parameters in the patients with RA showed significant improvement at each visit as follows: maximum grip force – P = 0.040, fatigue – P = 0.032, grip velocity – P = 0.026, and functional potential – P = 0.014 (Table 2). Nevertheless, they did not reach the values measured in the healthy controls.</p>
    </sec>
    <sec>
      <title>DISCUSSION</title>
      <p>This pilot study presents the results of the application of a new measuring system, involving a unique data processing algorithm and proposed parameters of the hand function. It also considers the implications of this system for rheumatology. Previous studies based on single-grip measurement found that hand grip strength and net forces vary by sex, age, and anthropometric characteristics (<italic>4</italic>, <italic>5</italic>). Generally, in conditions affecting the hand the observed dynamometric parameters increased, as strength, velocity, and grip stability grew (<italic>2</italic>). Compared to the baseline values, the increase in these parameters during the treatment represented a clear indicator of improvement of the hand function. The meticolous evaluation of the hand function using this new dynamometric system offers the possibility to plan appropriate exercises in order to obtain the best possible result. During a period of 6 months, the method showed good resolution at all stages.</p>
      <p>It is important to note that within the framework of this study, data on grip force and velocity are primarily significant in relative relations. Hence, they should be considered with caution, whereas for accurate absolute values of the abovementioned parameters it would be necessary to perform a study on a larger number of subjects and with a stringently defined protocol of device calibration (<italic>6</italic>). The development of this expert diagnostic system could allow an objective hand functional status evaluation. For further research, along with net functional force and velocity in hand grip evaluation, and with adequate probe modification, it would also be possible to analyze the grip force of a specific group of digits – mostly that of the thumb plus one finger (“pinch testing”).</p>
    </sec>
    <sec>
      <title>CONCLUSION</title>
      <p>In this pilot evaluation study we present a new electronic dynamometric system for obtaining hand function parameters based on dynamic measurements. By comparing the results of healthy subjects and patients, and by recording the changes occurring during the treatment, we can conclude that this system measures the hand condition objectively. It can be safely used to monitor the status of individual patients during treatment and rehabilitation as a relevant indicator of recovery. Further studies with a larger number of patients are needed to confirm its value.</p>
      <p>Conflict of interest statement: Authors declare no conflict of interest.</p>
    </sec>
    <sec>
      <title>REFERENCES / LITERATURA</title>
      <p>&lt;jrn&gt;1. Sheehy C, Gaffney K, Mukhtyar C. Standardized grip strength as an outcome measure in early rheumatoid arthritis. Scand J Rheumatol. 2013;42(4):289–93. <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/23311733">PubMed</ext-link> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.3109/03009742.2012.747624">https://doi.org/10.3109/03009742.2012.747624</ext-link>&lt;/jrn&gt;</p>
      <p>&lt;jrn&gt;2. Dias JJ, Singh HP, Taub N, Thompson J. Grip strength characteristics using force-time curves in rheumatoid hands. J Hand Surg Eur Vol. 2013;38(2):170–7. <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/22357327">PubMed</ext-link> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1177/1753193412439169">https://doi.org/10.1177/1753193412439169</ext-link>&lt;/jrn&gt;</p>
      <p>&lt;jrn&gt;3. Björk M, Thyberg I, Haglund L, Skogh T. Hand function in women and men with early rheumatoid arthritis. A prospective study over three years (the Swedish TIRA project). Scand J Rheumatol. 2006;35(1):15–9. <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/16467035">PubMed</ext-link> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1080/03009740510026562">https://doi.org/10.1080/03009740510026562</ext-link>&lt;/jrn&gt;</p>
      <p>&lt;jrn&gt;4. Beenakker KGM, Ling CH, Meskers CGM, et al. Patterns of muscle strength loss with age in the general population and patients with a chronic inflammatory state. Ageing Res Rev. 2010;9(4):431–6. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.arr.2010.05.005">https://doi.org/10.1016/j.arr.2010.05.005</ext-link> <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/20553969">PubMed</ext-link>&lt;/jrn&gt;</p>
      <p>&lt;jrn&gt;5. Chandrasekaran B, Ghosh A, Prasad C, et al. Age and anthropometric traits predict handgrip strength in healthy normals. J Hand Microsurg. 2010;2(2):58–61. <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1007/s12593-010-0015-6">https://doi.org/10.1007/s12593-010-0015-6</ext-link> <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/22282669">PubMed</ext-link>&lt;/jrn&gt;</p>
      <p>&lt;jrn&gt;6. Shiratori AP, da Rosa Iop R, Gomes Borges Júnior N, et al. Evaluation protocols of hand grip strength in individuals with rheumatoid arthritis: a systematic review. Rev Bras Reumatol. 2014;54(2):140–7. <ext-link ext-link-type="uri" xlink:href="https://pubmed.ncbi.nlm.nih.gov/24878861">PubMed</ext-link> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/j.rbr.2014.03.009">https://doi.org/10.1016/j.rbr.2014.03.009</ext-link>&lt;/jrn&gt;</p>
      <p>Figure 1. Hand grip acquisition system</p>
      <p>Table 1. Differences between patients and control group at baseline (T-test for independent groups)</p>
      <table-wrap>
        <table>
          <tbody>
            <tr>
              <td></td>
              <td>
                <p>Control group / Kontrolna skupina</p>
                <p>N = 12</p>
              </td>
              <td>
                <p>Patients / Bolesnici</p>
                <p>N = 12</p>
              </td>
              <td>t</td>
              <td>
                <italic>p</italic>
              </td>
              <td></td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td></td>
              <td>Mean / Srednja vrijednost</td>
              <td>SD</td>
              <td>Std. Error Mean / Standardna pogreška srednje vrijednosti</td>
              <td>Mean / Srednja vrijednost</td>
              <td>SD</td>
              <td>Std. Error Mean / Standardna pogreška srednje vrijednosti</td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Max grip force at baseline (N) / Maksimalna sila stiska izmjerena na početnome mjerenju (N)</td>
              <td>97,3</td>
              <td>3,5</td>
              <td>1,0</td>
              <td>68,2</td>
              <td>14,6</td>
              <td>4,2</td>
              <td>6,7</td>
              <td>&lt; 0,001</td>
            </tr>
            <tr>
              <td>Fatigue at baseline / Zamor šake na početnome mjerenju</td>
              <td>24,9</td>
              <td>0,3</td>
              <td>0,1</td>
              <td>22,4</td>
              <td>1,8</td>
              <td>0,5</td>
              <td>4,8</td>
              <td>&lt; 0,001</td>
            </tr>
            <tr>
              <td>Grip velocity at baseline (N/s) / Brzina stiska na početnome mjerenju (N/s)</td>
              <td>22,2</td>
              <td>1,3</td>
              <td>0,4</td>
              <td>14,8</td>
              <td>2,0</td>
              <td>0,6</td>
              <td>10,7</td>
              <td>&lt; 0,001</td>
            </tr>
            <tr>
              <td>Functional potential at baseline / Funkcio-nalni potencijal na početnome mjerenju</td>
              <td>1876,3</td>
              <td>174,1</td>
              <td>50,2</td>
              <td>808,2</td>
              <td>266,0</td>
              <td>76,8</td>
              <td>11,6</td>
              <td>&lt; 0,001</td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
      <p>Table 2. Changes in dynamometric variables during follow-up – patients with RA (n=12) (ANOVA)</p>
      <table-wrap>
        <table>
          <tbody>
            <tr>
              <td>Patients / Bolesnici N = 12</td>
              <td>Mean / Srednja vrijednost</td>
              <td>SD</td>
              <td>Wilks’ Lambda value / Wilksova lambda--vrijednost</td>
              <td>F</td>
              <td>
                <italic>p</italic>
              </td>
            </tr>
            <tr>
              <td>Max grip force at baseline (N) / Maksimalna sila stiska izmjerena na početku (N)</td>
              <td>68,2</td>
              <td>14,6</td>
              <td>0,41</td>
              <td>4,24</td>
              <td>0,040</td>
            </tr>
            <tr>
              <td>Max grip force after 2 months (N) / Maksimalna sila stiska izmjerena nakon 2 mjeseca (N)</td>
              <td>67,4</td>
              <td>12,4</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Max grip force after 4 months (N) / Maksimalna sila stiska izmjerena nakon 4 mjeseca (N)</td>
              <td>71,1</td>
              <td>14,1</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Max grip force after 6 months (N) / Maksimalna sila stiska izmjerena nakon 6 mjeseci (N)</td>
              <td>71,8</td>
              <td>13,6</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Fatigue at baseline / Zamor šake izmjeren na početku</td>
              <td>22,4</td>
              <td>1,8</td>
              <td>0,39</td>
              <td>4,63</td>
              <td>0,032</td>
            </tr>
            <tr>
              <td>Fatigue after 2 months / Zamor šake izmjeren nakon 2 mjeseca</td>
              <td>23,2</td>
              <td>1,5</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Fatigue after 4 months / Zamor šake izmjeren nakon 4 mjeseca</td>
              <td>23,7</td>
              <td>1,4</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Fatigue after 6 months / Zamor šake izmjeren nakon 6 mjeseci</td>
              <td>23,8</td>
              <td>1,6</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Grip velocity at baseline (N/s) / Brzina stiska izmjerena na početku (N/s)</td>
              <td>14,8</td>
              <td>2,0</td>
              <td>0,38</td>
              <td>4,97</td>
              <td>0,026</td>
            </tr>
            <tr>
              <td>Grip velocity after 2 months (N/s) / Brzina stiska izmjerena nakon 2 mjeseca (N/s)</td>
              <td>14,8</td>
              <td>2,3</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Grip velocity after 4 months (N/s) / Brzina stiska izmjerena nakon 4 mjeseca (N/s)</td>
              <td>15,9</td>
              <td>3,1</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Grip velocity after 6 months (N/s) / Brzina stiska izmjerena nakon 6 mjeseci (N/s)</td>
              <td>16,7</td>
              <td>3,1</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Functional potential at baseline / Funkcionalni potencijal izmjeren na početku</td>
              <td>808,2</td>
              <td>266,0</td>
              <td>0,32</td>
              <td>6,25</td>
              <td>0,014</td>
            </tr>
            <tr>
              <td>Functional potential after 2 months / Funkcionalni potencijal izmjeren nakon 2 mjeseca</td>
              <td>831,9</td>
              <td>251,6</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Functional potential after 4 months / Funkcionalni potencijal izmjeren nakon 4 mjeseca</td>
              <td>964,0</td>
              <td>332,1</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
            <tr>
              <td>Functional potential after 6 months / Funkcionalni potencijal izmjeren nakon 6 mjeseci</td>
              <td>1027,4</td>
              <td>340,1</td>
              <td></td>
              <td></td>
              <td></td>
            </tr>
          </tbody>
        </table>
      </table-wrap>
    </sec>
  </body>
  <back>
</back>
</article>
