<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "http://jats.nlm.nih.gov/publishing/1.0/JATS-journalpublishing1.dtd">
<article article-type="review-article" dtd-version="1.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">ADMET</journal-id>
<journal-title-group>
<journal-title>ADMET &#x0026; DMPK</journal-title>
<abbrev-journal-title>ADMET &#x0026; DMPK</abbrev-journal-title>
</journal-title-group>
<issn pub-type="epub">1848-7718</issn>
<publisher>
<publisher-name>International Association of Physical Chemists</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.5599/admet.2799</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Review</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Nano-modified biosensors for detection of pathogenic diseases: The prospect of smart, multiplex and point-of-care testing</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes">
<name><surname>Ibrahim</surname><given-names>Abdullahi Umar</given-names></name>
<xref ref-type="corresp" rid="cor1"><sup>*</sup></xref>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
<xref ref-type="aff" rid="aff002"><sup>2</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Pwavodi</surname><given-names>Pwadubashiyi Coston</given-names></name>
<xref ref-type="aff" rid="aff003"><sup>3</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Oszoz</surname><given-names>Mehmet</given-names></name>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Duwa</surname><given-names>Basil Barth</given-names></name>
<xref ref-type="aff" rid="aff001"><sup>1</sup></xref>
</contrib>
<contrib contrib-type="author">
<name><surname>Irkham</surname><given-names>Irkham</given-names></name>
<xref ref-type="aff" rid="aff004"><sup>4</sup></xref>
<xref ref-type="aff" rid="aff005"><sup>5</sup></xref>
</contrib>
<contrib contrib-type="author" corresp="yes">
<name><surname>Hartati</surname><given-names>Yeni Wahyuni</given-names></name>
<xref ref-type="corresp" rid="cor2"><sup>&#x2736;</sup></xref>
<xref ref-type="aff" rid="aff004"><sup>4</sup></xref>
<xref ref-type="aff" rid="aff005"><sup>5</sup></xref>
</contrib>
</contrib-group>
<aff id="aff001"><label>1</label> Department of Biomedical Engineering, <institution>Near East University</institution>, <addr-line>Nicosia, Mersin 10, Turkey</addr-line></aff>
<aff id="aff002"><label>2</label> Department of Medical Biochemistry, <institution>Kaduna State University</institution>, <addr-line>Kaduna, Nigeria</addr-line></aff>
<aff id="aff003"><label>3</label> Department of Bioengineering/Biomedical/Medical Engineering, Faculty of Engineering, <institution>Cyprus International University</institution>, <addr-line>Haspolat, 99258, Nicosia, North Cyprus, Turkey</addr-line></aff>
<aff id="aff004"><label>4</label> Department of Chemistry, Faculty of Mathematics and Natural Sciences, <institution>Padjadjaran University</institution>, <addr-line>Indonesia</addr-line></aff>
<aff id="aff005"><label>5</label> Study Centre of Sensors and Green Chemistry, Faculty of Mathematics and Natural Sciences, <institution>Padjadjaran University</institution>, <addr-line>Indonesia</addr-line></aff>
<author-notes>
<corresp id="cor1">Corresponding Author: E-mail: <sup>*</sup><italic><email>abdullahi.umaribrahim@neu.edu.tr</email></italic></corresp>
<corresp id="cor2"><sup>&#x2736;</sup><italic><email>yeni.w.hartati@unpad.ac.id</email></italic></corresp>
</author-notes>
<pub-date pub-type="epub">
<day>09</day>
<month>07</month>
<year>2025</year>
</pub-date>
<pub-date pub-type="collection">
<year>2025</year>
</pub-date>
<volume>13</volume>
<issue>4</issue>
<elocation-id>2799</elocation-id>
<history>
<date date-type="received">
<day>11</day>
<month>05</month>
<year>2025</year>
</date>
<date date-type="rev-recd">
<day>03</day>
<month>07</month>
<year>2025</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2025 by the authors.</copyright-statement>
<copyright-year>2025</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
<license-p>This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (<ext-link ext-link-type="uri" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://creativecommons.org/licenses/by/4.0/">http://creativecommons.org/licenses/by/4.0/</ext-link>).</license-p>
</license>
</permissions>
<abstract>
<title>Abstract</title>
<sec>
<title>Introduction and background</title>
<p>The world has witnessed several outbreaks, emergence and re-emergence of infectious diseases throughout the 21<sup>st</sup> century as a result of climate change, urbanization and migration. Several infectious diseases caused by pathogens such as SARS-CoV-2, Ebola, Zika, Dengue, Marburg viruses, <italic>Mycobacterium tuberculosis</italic>, etc. have caused a devastating impact on lives and livelihoods around the world. To counter these diseases, medical experts rely on conventional techniques, which include microscopy and serological testing. However, these conventional methods are hindered by several trade-offs, including high cost, longer processing times, low sensitivity, and a likelihood of false positive results. Biomedical sensors have gained momentum in clinical diagnostics due to their low cost, portability, and sensitivity, among other advantages. To improve their performance, scientists have incorporated nanomaterials. Other techniques used to enhance the performance of nanobiosensors include multiplex testing, point-of-care testing (POCT), and smart sensing.</p>
</sec>
<sec>
<title>Methodology</title>
<p>Thus, in this review, we present a comprehensive overview of the state-of-the-art nanobiosensors for detecting infectious diseases. The review covers key topics that are centred around the application of nanotechnology in biosensing, multiplex testing, POCT and smart nano-enhanced biosensors.</p>
</sec>
<sec>
<title>Findings</title>
<p>The findings of this review highlighted the advantages of biosensors over conventional approaches, with a limit of detection ranging from nanomolar to attomolar concentrations and a time response ranging from 1 to 3 hours.</p>
</sec>
<sec>
<title>Conclusion</title>
<p>Despite the prospect of nanobiosensors, several limitations exist, including complexity, extensive processing time, and others. Moreover, the integration of smart technologies in nanobiosensors can offer several benefits, including high accuracy and faster detection and prediction.</p>
</sec>
</abstract>
<kwd-group>
<title>Keywords</title>
<kwd>Nanobiosensors</kwd>
<kwd>infectious diseases</kwd>
<kwd>smart technology</kwd>
<kwd>immunosensors</kwd>
<kwd>genosensors</kwd>
<kwd>electrochemical</kwd>
<kwd>optical</kwd>
</kwd-group>
<funding-group>
<funding-statement>No funding</funding-statement>
</funding-group>
<counts>
<fig-count count="3"/>
<table-count count="4"/>
<equation-count count="0"/>
<ref-count count="97"/>
<page-count count="23"/>
</counts>
</article-meta>
</front>
<body>
<sec id="sec1-1">
<title>1. Introduction</title>
<p>Since the beginning of writing, ancient civilizations have recorded many infectious diseases which have impacted people's lives [<xref ref-type="bibr" rid="ref1">1</xref>]. Several diseases have been recorded throughout history, with some causing global havoc in terms of mortality and fatality [<xref ref-type="bibr" rid="ref2 ref3">2-3</xref>]. The progress made in medical care has led to the classification of diseases into several categories, which include pathogenic diseases, hereditary diseases, deficiency diseases, and psychological diseases [<xref ref-type="bibr" rid="ref4 ref5">4-5</xref>]. Diseases can also be classified into communicable and non-communicable diseases, as well as zoonotic diseases, waterborne diseases, and foodborne diseases [<xref ref-type="bibr" rid="ref6 ref7">6-7</xref>]. Among these types of diseases, infectious diseases caused by pathogens such as viruses, bacteria, fungi and parasites pose a serious problem to global health. Several infectious diseases can be transmitted from one person to another. Over the years, infectious diseases have caused several epidemics and pandemics and have resulted in millions of deaths globally [<xref ref-type="bibr" rid="ref8 ref9">8-9</xref>].</p>
<p>Identifying pathogens responsible for causing an infection is of paramount importance to medical care. Several techniques have been developed over the years, ranging from culturing and microscopy to spectroscopy, serological assays such as enzyme-linked immunosorbent assay (ELISA), lateral flow tests, PCR, and biosensors [<xref ref-type="bibr" rid="ref10 ref11 ref12">10-12</xref>]. Despite wide arrays of these approaches, they have several drawbacks which include low sensitivity, low specificity or selectivity, low throughput, false positive results, lack of point-of-care testing (POCT), expensive, longer processing time, laborious sample collection and processing procedures, the need for train expert, contamination and safety concerns, the use of toxic chemicals, requirement of large-scale devices, longer wait time for test results etc. Therefore, there is a need for an effective approach that can address these limitations [<xref ref-type="bibr" rid="ref10">10</xref>].</p>
<p>The development of the first glucose biosensors has transformed the landscape of biomedical sensors and laid the groundwork for the advancement of biosensors in clinical diagnosis of infectious diseases [<xref ref-type="bibr" rid="ref13">13</xref>]. Biosensors for infectious disease detection have been developed to identify or recognize pathogen-related biomolecules or components using highly sensitive and specific recognition elements such as NA (DNA, RNA, aptamers), antigens and antibodies, enzymes, whole cells or cell organelles. Apart from biorecognition elements, biosensors also require transduction and signal amplification systems, such as optical, electrical, electrochemical, mechanical, <italic>etc</italic>. [<xref ref-type="bibr" rid="ref14">14</xref>]. Biosensors offer several advantages, which include high sensitivity, miniaturization, ease of operation and low cost [<xref ref-type="bibr" rid="ref15 ref16">15-16</xref>].</p>
<p>The integration of nanotechnology for the development of nanobiosensors or nano-biomedical sensors has emerged as a viable approach to address the limitations of conventional approaches. Nano-modified biosensors have been shown to improve conductivity, diagnostic accuracy, sensitivity, fast response, <italic>etc</italic>. [<xref ref-type="bibr" rid="ref17 ref18 ref19">17-19</xref>]. Several nanomaterials possess desirable characteristics, including small size, excellent electrical conductivity, high dispersity, large surface area, optical properties, physicochemical properties, and ease of functionalization, which make them ideal for biosensing technologies. Several nanoscale structures have been incorporated in biomedical sensors for detection of infectious diseases, some of which includes Carbon-based NMs such as graphene and its derivatives such as graphene oxide (GO), reduced GO, nitrogen-doped graphene, carbon black (super P), metallic nanoparticles (NPs) such as copper, gold, palladium, aluminium, cobalt, iron, metallic oxides such as zinc, manganese, zirconium and titanium oxides, carbon-based nano-structurers, quantum dots, magnetic NPs, polymeric nanomaterials, nanofibers, fluorescent nano clusters <italic>etc</italic>. [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref20">20</xref>]. Moreover, the integration of nanotechnology in biosensing applications offers opportunities for the fabrication of cheaper, faster and more sensitive biosensors [<xref ref-type="bibr" rid="ref18 ref19">18-19</xref>].</p>
<p>Another challenge facing the diagnosis of infectious diseases includes the lack of POCT and multiplex testing [<xref ref-type="bibr" rid="ref21 ref22">21-22</xref>]. The emergence of infectious diseases in rural areas and underdeveloped countries requires the collection of samples from the site of infection and subsequent transportation to countries with standard medical facilities, which increases cost, processing time and increases the likelihood of contamination and false positive results. Therefore, there is a high demand for POC-based biosensors that can enable onsite detection [<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref23">23</xref>,<xref ref-type="bibr" rid="ref24">24</xref>]. Consequently, as the number of infectious diseases surges coupled with the advancement of the healthcare system, medical laboratories require more effective and cost-effective procedures to manage their increasing workload [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref25">25</xref>]. To address this issue, multiplex testing has emerged as a critical approach and is currently being adopted in clinical practices [<xref ref-type="bibr" rid="ref26 ref27">26-27</xref>]. To enhance the performance of nanobiosensors, scientists have started incorporating cutting-edge technologies such as wireless technology, internet of things (IoT) or internet of medical things (IoMT), artificial intelligence (AI), cloud computing, big biomedical data (BBD), 3-D printing, <italic>etc</italic>. The prospect of smart nanobiosensors is gaining interest due to their potential for real-time detection, disease monitoring, surveillance, and epidemic control, among other applications [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref28">28</xref>]. Thus, the continuous need for fast and effective triage of patients, identification of individuals infected with a specific disease, vulnerable individuals, and those at risk, as well as tracking of infection progression, warrants the use of smart technology [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref29">29</xref>].</p>
<sec id="sec2-1">
<title>1. 1. Comparison with related review</title>
<p>The review reported by Dhahi <italic>et al.</italic> [<xref ref-type="bibr" rid="ref12">12</xref>] shares a close similarity with our review, focusing on nanobiosensors for infectious diseases. The review covers several key areas, including background on infectious diseases, outbreaks, modes of transmission, impacts, challenges, and a gateway to nanobiosensors, as well as future directions and conclusions. However, the review does not include the detailed prospects of smart technologies, multiplex testing and POCT.</p>
<p>Another review discussing the application of nano-modified sensors for detecting infectious diseases is presented by Rios <italic>et al.</italic> [<xref ref-type="bibr" rid="ref19">19</xref>]. The review outlines key issues, including nanosensors, antibody-based, NA-based, and peptide-based applications, as well as agricultural and industrial applications, future perspectives, and conclusions. The review differs from our review based on the scope (animal infectious diseases vs human infectious diseases). Moreover, the review does not include the potential of smart nanobiosensors for multiplex and POCT. Similarly, the review presented by Singh <italic>et al.</italic> [<xref ref-type="bibr" rid="ref18">18</xref>] focuses solely on nanobiosensors and their applications in infectious disease management.</p>
<p>The review presented by Irkham <italic>et al.</italic> [<xref ref-type="bibr" rid="ref11">11</xref>] shared a close similarity with this review in terms of nanotechnology and clinical diagnostics. Despite the shared scope, the review is limited to graphene-based electrochemical nanobiosensors. Moreover, the study does not include multiplex testing. The review reported by Kerry <italic>et al.</italic> [<xref ref-type="bibr" rid="ref7">7</xref>] highlighted the application of nanotechnology for the detection of non-communicable and communicable diseases. The study covers several topics, including detailed information on biosensors, application of nanotechnology in biosensing, application of nano-integrated biosensors for detection of communicable diseases (viruses, fungi, bacteria, parasites) and non-communicable diseases (Parkinson's, Alzheimer's, neonatal disorders, bilirubin), commercialization of nanobiosensors and future prospects. Smart, multiplex, and POCT do not fall within the scope of the study. The summary of the comparison with the related review is presented in <xref ref-type="table" rid="table001">Table 1</xref>.</p>
<table-wrap id="table001" position="float" orientation="portrait">
<label>Table 1.</label>
<caption><p>Comparison with related review</p></caption>
<table rules="all" frame="box">
<thead>
<tr>
<th align="center" valign="middle">Biosensors</th>
<th align="center" valign="middle">Nanotechnology</th>
<th align="center" valign="middle">POCT</th>
<th align="center" valign="middle">Multiplex testing</th>
<th align="center" valign="middle">Smart technology</th>
<th align="center" valign="middle">Open research</th>
<th align="center" valign="middle">Ref.</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref12">12</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref19">19</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref18">18</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref11">11</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">X</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref7">7</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">&#x2713;</td>
<td align="center" valign="middle">This study</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
</sec>
<sec id="sec1-2" sec-type="methods">
<title>2. Methodology and objectives</title>
<p>Rapid, ultra-sensitive, ultrafast, simple, free amplification, free sample pre-treatment, POC and multiplex testing have long been key objectives for medical practitioners. Therefore, the main focus of this review revolves around the application of nanotechnology in biosensing techniques for POCT, multiplex and smart detection of pathogenic diseases. The main idea behind the formulation of the research questions stemmed from the scarcity of comprehensive reviews on the subjects and the pressing need, underlined by the emergence of pathogenic diseases and the limitations of conventional approaches. The research questions include:</p>
<list list-type="bullet">
<list-item><p>How do nano-modified biosensors enhance the sensitivity and specificity of pathogen detection compared to traditional diagnostic methods?</p></list-item>
<list-item><p>How can nano-modified biosensors be optimized for POCT to enable rapid, accurate, and user-friendly diagnosis of pathogenic diseases in resource-limited settings?</p></list-item>
<list-item><p>What are the current or key challenges in developing smart, multiplexed, and point-of-care nano-modified biosensors for the detection of pathogenic diseases?</p></list-item>
</list>
<sec id="sec2-2">
<title>2. 1. Literature search strategy and inclusion criteria</title>
<p>There is a plethora of review articles that cover the application of nanotechnology in biosensing technologies. However, there is no recent review that hyphenates biosensors, nanotechnology, POCT, multiplex testing and smart technology. The initial search for articles used in this review was based on Google Scholar search using keywords such as biosensors, nanotechnology, nano-biosensors, nano-modified sensors, detection of pathogenic disease (specific to a pathogen) using nano-enhanced biosensors, electrochemical-based biosensors for detection of pathogenic disease, POC-based biosensors, multiplex detection, smart biosensors, <italic>etc</italic>. For basic information regarding subjects such as nanotechnology, biosensors, and infectious diseases, we relied on articles retrieved from Google Scholar and the Web of Science. While for research articles that reported the development of nano-modified biosensors for the detection of specific pathogens, we only relied on articles retrieved from Web of Science (Emerging Source Citation Index, (ESCI), Science Citation Index (SCI) and Science Citation Index Expanded (SCIE)). We focused on articles published within the 10-year span (<italic>i.e.</italic> 2015-2025).</p>
<p>We retrieved 238 articles from both Google Scholar and Web of Science. We selected 96 papers published in various outlets, including Springer, ScienceDirect, and Taylor &#x0026; Francis. The main selection criteria prioritized articles that undergo peer review, have strong scientific content, and are written in English.</p>
</sec>
<sec id="sec2-3">
<title>2. 2. Scope</title>
<p>This review article aims to provide an overview of the prospects of the integration of nanotechnology and smart technology for the development of biosensors for the detection of infectious diseases. The review is structured using key topics, which include an overview of biosensors, working principles, and types (based on bioreceptors and transduction). The state-of-the-art studies that reported the development of nano-modified biosensors for infectious disease detection are also outlined. Moreover, the concept of smart technology, which includes wireless and IoT systems, AI, and BBD, is also highlighted.</p>
<p>The remaining part of this review is organized as follows. <xref ref-type="sec" rid="sec1-3">Section 3</xref> reviews existing studies that have reported the use of nanotechnology to enhance biosensing capabilities for the detection of infectious diseases. Moreover, the chapter also covers multiplex testing and the prospect of smart technologies in biosensing. <xref ref-type="sec" rid="sec1-4">Section 4</xref> highlights the key findings and open research issues, and lastly, <xref ref-type="sec" rid="sec1-5">Section 5</xref> constitutes the conclusion.</p>
</sec>
</sec>
<sec id="sec1-3">
<title>3. Applications of nanobiosensors for the detection of pathogenic diseases</title>
<sec id="sec2-4">
<title>3. 1. Pathogenic diseases</title>
<p>Pathogenic diseases are characterized by infections caused by various microorganisms, which include bacteria, viruses, fungi and parasites [<xref ref-type="bibr" rid="ref15">15</xref>]. Pathogenic diseases can be categorized into two classes based on their spread, which include communicable and non-communicable diseases. Communicable diseases are the type that can be transmitted from a host or reservoir to a healthy person. Some of the transmission approaches include direct contact, animal-to-human transmission, water contamination, air contamination, and food contamination. Pathogenic diseases induce a range of symptoms, varying from acute to critical or life-threatening [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref30">30</xref>,<xref ref-type="bibr" rid="ref31">31</xref>].</p>
<sec id="sec3-1">
<title>3. 1. 1. Viruses</title>
<p>Pathogenic viruses are responsible for causing several diseases and contribute to morbidity and mortality every year. Example of pathogenic viruses include Ebola which caused haemorrhagic fever, hepatitis, human immunodeficiency virus/acquired immunodeficiency syndrome (AIDS), SARS-CoV-1, SARS-CoV-2, Middle East respiratory syndrome (MERS), Dengue which caused dengue haemorrhagic fever (DHF) and dengue shock syndrome (DSS), Zika, Influenza, Yellow fever virus, Rotavirus etc. Viruses are characterized as the smallest disease-causing agents known to humans [<xref ref-type="bibr" rid="ref10">10</xref>,<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref32">32</xref>]. Unlike bacteria, viruses store their genetic information in the form of RNA and require a host cell to replicate through hijacking host replication machinery, resulting in the production of millions of new viral particles [<xref ref-type="bibr" rid="ref33">33</xref>]. Several viral diseases are associated with severe symptoms, which necessitate proper disease management.</p>
</sec>
<sec id="sec3-2">
<title>3. 1. 2. Bacteria</title>
<p>The world has been battling against pathogenic bacteria, which continue to pose serious health concerns. Bacterial infections are responsible for millions of deaths worldwide. Currently, there are several pathogenic bacteria which pose serious health issues; some of these bacteria include <italic>Staphylococcus aureus</italic> (<italic>S. aureus</italic>) associated with gastrointestinal tract disease, shock syndrome and septicemia [<xref ref-type="bibr" rid="ref34">34</xref>], <italic>Mycobacterium tuberculosis, Salmonella, Escherichia coli, Streptococcus pneumonia, Vibrio cholerae</italic>, <italic>etc</italic>. [<xref ref-type="bibr" rid="ref35">35</xref>]. Unlike viruses, store their genetic information in the form of DNA, which is typically a single circular chromosome [<xref ref-type="bibr" rid="ref36">36</xref>]. Bacteria can be categorized based on their shapes, such as spherical (cocci), rod-shaped (bacilli) and spiral shape (spirilla) [<xref ref-type="bibr" rid="ref37 ref38">37-38</xref>]. Moreover, bacteria can be categorised into Gram-positive and Gram-negative based on the staining technique. Gram-negative bacteria are characterized as bacteria that do not retain violet stain and typically appear red or pink under the microscope. Gram-positive bacteria are characterized as those that retain violet stain and appear purple under the microscope [<xref ref-type="bibr" rid="ref39">39</xref>].</p>
</sec>
</sec>
<sec id="sec2-5">
<title>3. 2. Application of nano-modified biosensors for the detection of viruses</title>
<p>Over the last 2 decades, several studies have reported the development of nano-modified based biosensors for the detection and quantification of pathogenic diseases which include the recent SARS-COV2, Dengue, Zika, papillomavirus (HPV), HIV, Ebola, Chikungunya, Influenza, SARS-CoV-2, HIV, Hepatitis B and C, Zika, Ebola, as well as the need for adaptable and fast-deploying nanobiosensors and potential for point-of-care (POC) diagnostics [<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref11">11</xref>,<xref ref-type="bibr" rid="ref12">12</xref>,<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref19">19</xref>].</p>
<p>The development of rapid, sensitive, POC and early detection of Ebola virus disease (EVD) using nano-modified immunosensor is presented by Chen <italic>et al.</italic> [<xref ref-type="bibr" rid="ref23">23</xref>]. The biosensor is designed based on a reduced graphene oxide-based field-effect transistor (FET) method. The detection criteria rely on the rGO as a conducting channel electrode, which is thermally annealed on the electrode through chemical absorption. An Al<sub>2</sub>O<sub>3</sub> layer and gold nanoparticles are also incorporated on top of the FET. The channel is subsequently immobilized with anti-Ebola probes that can specifically capture the target antigen. Evaluation of the biosensor has shown that it can successfully detect the target (Zaire strain) down to a LOD of 1 ng mL<sup>1</sup>. To evaluate selectivity and sensitivity, two viral samples, which include Marburg and Sudan viruses, are used as control samples.</p>
<p>Kaushik <italic>et al.</italic> [<xref ref-type="bibr" rid="ref24">24</xref>] developed an electrochemical-based immunosensor for the detection of ZIKV. The biosensing strategy revolves around the functionalization of interdigitated microelectrodes of gold (IDE-Au) and immobilization of ZIKV-specific envelop protein antibody onto dithiobis(succinimidyl propionate). The resulting interaction between the immobilized antibody and target ZIKV was measured based on electrochemical impedance spectroscopy (EIS). Evaluation of the developed electrochemical-based immunesensor resulted in an LOD of 10 pM and a detection range from 10 pM to 1 nM. The developed biosensor has the potential for POCT through the integration of the biosensing chip with a miniaturized potentiostat (MP)-interfaced with a smartphone.</p>
<p>Zang <italic>et al.</italic> [<xref ref-type="bibr" rid="ref40">40</xref>] reported the development of a nano-modified immunosensor for the rapid and ultra-sensitive detection of Ebola virus (EBOV) antigens. The biosensor is a 3D plasmonic nanoantenna assay sensor consisting of a silicon dioxide nanopillar array, Au nanodisk, Au nanodots, and Au backplane, which exhibits substantial fluorescence intensity enhancement. The nanoantenna array immunosensor comprises a thin layer of plasmonic nanoantenna array with its surface connected to a molecular linker layer. EBOV capture agents are used to detect two Ebola antigens, which include EBOV sGP and EBOVgp-Fc, via a sandwich assay protocol. The nanoantenna-based immunosensor can successfully detect EBOV soluble glycoprotein (sGP) in human plasma down to an LOD of 220 fg mL<sup>-1</sup>. Side-by-side comparison using ELISA was also conducted to verify the performance of the developed biosensor.</p>
<p>Chowdhury <italic>et al.</italic> [<xref ref-type="bibr" rid="ref41">41</xref>] developed an electrochemical-based nanobiosensor for the detection of the Hepatitis E virus. The electrode of the biosensor was fabricated using graphene quantum dots (GQDs) and gold-embedded polyaniline nanowires coupled with the immobilization of anti-HEV antibody. To increase sensitivity, the study introduced an external electrical pulse during virus accumulation. The nano-electrochemical-based biosensor was deployed to detect specific HEV genotypes (G1, G3, G7 and ferret HEV). Consequently, the developed framework is compared with real-time quantitative reverse transcription-polymerase chain (RT-qPCR), which resulted in similar sensitivity. Assessment of the developed biosensor has shown that it can detect HEV with a wide linear range of 1 fg mL<sup>-1</sup> to 100 pg mL<sup>-1</sup> and a low detection limit of 0.8 fg mL<sup>-1</sup> under optimal conditions. Moreover, to assess the sensitivity and specificity of the developed nanobiosensor, it is tested using HEV-like particles (HEV-LPs) in buffer and human serum.</p>
<p>The development of an electrochemical-based immunosensor for the multiplex detection of MERS-CoV and human coronavirus (HCoV) is reported by Layqah and Eissa [<xref ref-type="bibr" rid="ref42">42</xref>]. In order to accomplish rapid and accurate detection of the target protein, the biosensor is fabricated by functionalizing carbon electrodes with AuNPs and subsequent immobilization of recombinant spike protein as a biomarker for MERS-CoV. The multiplexed detection of different MERS-CoV is owed to the utilization of arrays of electrodes. The biosensing approach revolves around the indirect competition between free virus and immobilized MERS-CoV protein for a fixed concentration of antibody incorporated into the sample. Assessment of the developed nano-modified immunosensor has shown that it can be conducted in 20 min with LOD of 0.4 and 1.0 pg mL<sup>-1</sup> for HCoV and MERS-CoV, respectively and linear response from 0.001-100 ng mL<sup>-1</sup> and 0.01-10,000 ng mL<sup>-1</sup> for MERS-CoV and HCoV, respectively.</p>
<p>As a result of the need for a rapid technique that supports widespread testing to mitigate the spread of SARS-CoV-2, Torrente-Rodr&#x00ED;guez <italic>et al.</italic> [<xref ref-type="bibr" rid="ref43">43</xref>] developed a graphene-based multiplexed telemedicine platform known as SARS-CoV-2 RapidPlex for rapid, ultra-sensitive and low-cost detection of COVID-19 using saliva and serum samples. The platform is designed based on target-specific immunoassays constructed using laser-engraved graphene for the rapid and remote assessment of SARS-CoV-2 biomarkers, including anti-spike protein IgG and IgM, nucleocapsid protein, and C-reactive protein (CRP). Laser-engraved graphene (LEG) undergoes functionalization and modification steps for the covalent attachment of receptors. The multiplex detection of target biomarkers provides information that includes viral infection, immune response, and disease severity. The assessment of the immunosensor using serum and saliva resulted in concentration range from 0.1-0.8 &#x03BC;g mL<sup>-1</sup> and 0.5-2.0 ng mL<sup>-1</sup> for nucleocapsid protein, 20 to 40 &#x03BC;g mL<sup>-1</sup> and 0.2 to 0.5 &#x03BC;g mL<sup>-1</sup> for S1-IgG, 20 to 50 &#x03BC;g mL<sup>-1</sup> and 0.6 to 5.0 &#x03BC;g mL<sup>-1</sup> for S1-IgM and 10 to 20 &#x03BC;g mL<sup>-1</sup> and 0.1 to 0.5 &#x03BC;g mL<sup>-1</sup> CRP. The summary of the SARS-CoV-2 RapidPlex platform is presented in <xref ref-type="fig" rid="fig001">Figure 1</xref>.</p>
<fig id="fig001" position="float">
<label>Figure 1.</label>
<caption><p>SARS-CoV-2 RapidPlex. A-D. Comprises of WEs: (4 graphene); RE: Ag/AgCl; CE: Graphene. All the electrodes (6: 4 WEs and 1 RE and 1 CE) are patterned on a polyimide (PI) substrate via CO<sub>2</sub> laser engraving. Detection of target proteins and specific immunoglobulins via sandwich and direct immunosensing approaches onto laser-engraved graphene (LEG) electrodes</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ADMET-13-2799-g001.jpg" mime-subtype="jpg"/>
</fig>
<p>Siew <italic>et al.</italic> [<xref ref-type="bibr" rid="ref44">44</xref>] reported the construction of a high-performance immunosensor fabricated with graphene/titanium dioxide (G/TiO<sub>2</sub>) for the detection of Dengue virus IgG antibodies. The experiment was set up using a screen-printed carbon electrode (SPCE) modified with a G/TiO<sub>2</sub> nanocomposite and the Plant-derived dengue envelope domain III (EDIII) protein as an antigenic probe. Evaluation of the immunosensor displays excellent results in terms of specificity (discriminating between dengue and Zika virus) and sensitivity with LOD of 2.81 ng mL<sup>-1</sup> and a wide linear range from 62.5-2000 ng mL<sup>-1</sup>. The results also indicate consistency with those obtained using ELISA with mouse serum samples.</p>
<p>Lee <italic>et al.</italic> [<xref ref-type="bibr" rid="ref45">45</xref>] developed an electrochemical-based genobiosensor enhanced with gold NPs for the ultra-sensitive detection of Dengue virus. The biosensor is designed based on the use of methylene blue-functionalized Au NPs coupled with CRISPR/Cpf1 (Cas12). The detection process revolves around the deployment of CRISPR/Cpf1, which recognizes and randomly cleaves target nucleic acid as a result of its nonspecific ssDNA trans-cleavage activity. The developed nano-modified genobiosensor can detect target dengue fever viral samples down to a LOD of 100 fM. The biosensor has demonstrated the ability to detect samples within 30 minutes, eliminating the need for an RNA amplification step.</p>
<p>The development of a cost-effective, simple, ultrafast and rapid biosensing approach for the detection of EBOV is reported by Chen <italic>et al.</italic> [<xref ref-type="bibr" rid="ref46">46</xref>]. The study developed an assay featuring nanobody-conjugated NPs for rapid, electronic detection (Nano2RED). The detection mechanism revolves around the use of generated nanobodies conjugated to AuNPs for in-solution colorimetric detection of EBOV secreted glycoprotein (sGP) target. Evaluation of the nano-modified optical immunosensor has shown that it can detect with a LOD of 350 pM and a dynamic range from 100 pM to 1 &#x03BC;M. The developed biosensor is also compared with ELISA to establish consistency.</p>
<p>Yadav <italic>et al.</italic> [<xref ref-type="bibr" rid="ref47">47</xref>] proposed the development of an electrochemical-based immunosensor fabricated using a nanocomposite made of molybdenum disulfide nanosheets decorated with polydopamine (MoS2-PDA) for the detection of SARS-CoV-2 nucleocapsid protein (N protein). Detection of the target revolves around the functionalization of the nanocomposite with anti-SARS-CoV-2 nucleocapsid IgG antibody (Ab), followed by quantification via EIS. The assessment of the fabricated nanocomposite-enhanced immunosensor resulted in a LOD of and 2.80 ag mL<sup>-1</sup> and a limit of quantification (LOQ) of 8.48 ag mL<sup>-1</sup> and a linear range from 10 ag mL<sup>-1</sup> and 100 ng mL<sup>-1</sup>. Moreover, the biosensor was also compared with the results obtained using a conventional RT-PCR test based on the detection of N protein in nasopharyngeal swab specimens, indicating consistency.</p>
<p>Sangili <italic>et al.</italic> [<xref ref-type="bibr" rid="ref48">48</xref>] developed a label-free electrochemical-based immunosensor enhanced with a nanocomposite for the rapid detection of DENV protein. The biosensing strategy revolves around the in-situ reduction and functionalization of AuNPs decorated with heteroatom-doped reduced graphene oxide nanocomposites coupled with the immobilization of an antibody. The result of the fabricated immunosensor exhibited LOD of 1.6 pg mL<sup>-1</sup> and a wide range from 0.01 to 100 ng mL<sup>-1</sup>. The platform was also tested for the detection of viral E-protein contents in serum samples and subsequently compared with the results recorded using the ELISA approach.</p>
<p>Del Ca&#x00F1;o <italic>et al.</italic> [<xref ref-type="bibr" rid="ref49">49</xref>] reported the development of an amplification-free electrochemical-based genosensor modified using Gold nanotriangles (AuNTs) for the detection of SARS-CoV-2. The biosensing strategy revolves around the functionalization of AuNTs with dithiolated oligonucleotides and the subsequent hybridization with either single-stranded DNA or RNA sequences of SARS-CoV-2 of different lengths, resulting in quantification. The developed electrochemical genosensor can also detect point mutations in the viral genome and discriminate between variants, including Alpha, Beta, Gamma, Delta, and Omicron. The evaluation of the platform resulted in LOD of 22.2fM and LOQ of 75.7 fM. The result achieved is compared with RT-qPCR to ensure consistency. In addition, the genobiosensor is also employed to detect the target in nasopharyngeal swab samples from COVID-19 and has been shown to accurately discriminate between infected and non-infected cases.</p>
<p>Braz <italic>et al.</italic> [<xref ref-type="bibr" rid="ref50">50</xref>] reported the development of an electrochemical immunosensor fabricated using AuNPs for the detection of SARS-CoV. The nano-modified immunosensor is designed based on solid-binding for the detection of SARS-CoV-2 anti-S antibodies. The mechanism behind the detection procedure revolves around the use of a peptide as a recognition site with two regions. The first region is based on the viral receptor binding domain, which is capable of recognizing antibodies of the spike protein, while the second region is designed for interacting with AuNPs. AuNP-binding peptide dispersion is utilized to modify the screen-printed carbon electrode (SPCE). To evaluate the detection capability of the developed nanobiosensor, differential pulse voltammetry was used. The result indicated that the biosensor could detect the target with a LOD of 30 ng mL<sup>-1</sup> and a linear working range from 75 ng mL<sup>-1</sup> to 15 &#x03BC;g mL<sup>-1</sup>.</p>
<p>The development of a digital CRISPR-powered nano-modified genosensor for the detection of DENV is reported by Freko <italic>et</italic> al. [<xref ref-type="bibr" rid="ref51">51</xref>]. The developed genosensor combined the collateral cleavage activity of the Cas12a enzyme with a digital sensing strategy, based on the oxidation events of DNA-coated AgNPs on a microelectrode array. Evaluation of the nano-enhanced biosensor has demonstrated that it can successfully detect targets at concentrations as low as 25 pM. The biosensor has demonstrated the ability to detect the target within 50 minutes. The application of nano-modified biosensors for the detection of viruses is summarized in <xref ref-type="table" rid="table002">Table 2</xref>.</p>
<table-wrap id="table002" position="float" orientation="portrait">
<label>Table 2.</label>
<caption><p>Application of nano-modified biosensors for the detection of viruses</p></caption>
<table rules="all" frame="box">
<thead>
<tr>
<th align="center" valign="middle">Type of Biosensors</th>
<th align="center" valign="middle">Nanomaterial</th>
<th align="center" valign="middle">Target</th>
<th align="center" valign="middle">LOD</th>
<th align="center" valign="middle">References</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">rGO and AuNPs</td>
<td align="center" valign="middle">EBOV</td>
<td align="center" valign="middle">1 ng mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref23">23</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">IDE-Au</td>
<td align="center" valign="middle">ZIKV</td>
<td align="center" valign="middle">10 pM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref24">24</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">Nanoantenna array</td>
<td align="center" valign="middle">EBOV</td>
<td align="center" valign="middle">220 fg mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref40">40</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">GQDs and AuNP-PAni</td>
<td align="center" valign="middle">Hepatitis E virus</td>
<td align="center" valign="middle">0.8 fg mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref41">41</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">AuNP</td>
<td align="center" valign="middle">MERS-CoV and HCoV</td>
<td align="center" valign="middle">0.4 and 1.0 pg mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref42">42</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">LEG</td>
<td align="center" valign="middle">SARS-CoV-2</td>
<td align="center" valign="middle">0.1&#x2013;50 &#x03BC;g mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref43">43</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">G/TiO<sup>2</sup></td>
<td align="center" valign="middle">DENV</td>
<td align="center" valign="middle">2.81 ng mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref44">44</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Genosensor</td>
<td align="center" valign="middle">AuNPs</td>
<td align="center" valign="middle">DENV</td>
<td align="center" valign="middle">100 fM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref45">45</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">AuNPs</td>
<td align="center" valign="middle">EBOV</td>
<td align="center" valign="middle">350 pM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref46">46</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">MoS<sub>2</sub>-PDA</td>
<td align="center" valign="middle">SARS-CoV-2</td>
<td align="center" valign="middle">2.80 ag mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref47">47</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">AuNPs</td>
<td align="center" valign="middle">DENV</td>
<td align="center" valign="middle">1.6 pg mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref48">48</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Genosensor</td>
<td align="center" valign="middle">AuNTs</td>
<td align="center" valign="middle">SARS-CoV-2</td>
<td align="center" valign="middle">22.2 fM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref49">49</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">AuNPs</td>
<td align="center" valign="middle">SARS-CoV-2</td>
<td align="center" valign="middle">30 ng mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref50">50</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Genosensor</td>
<td align="center" valign="middle">AgNPs</td>
<td align="center" valign="middle">DENV</td>
<td align="center" valign="middle">25 pM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref51">51</xref>]</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec2-6">
<title>3. 3. Application of nano-modified biosensors for the detection of bacteria</title>
<p>Kaur <italic>et al.</italic> [<xref ref-type="bibr" rid="ref52">52</xref>] proposed the construction of Bridged Rebar Graphene (BRG) nanostructured aptasensor for the rapid detection of pathogenic <italic>E. coli</italic>. The proposed biosensor was designed based on the functionalization of BRG onto the fabricated nanostructured aptasensor. The biosensing strategy revolves around bacteria-DNA interactions captured on the BRG nanostructured electrode by using specific anti-E. coli DNA aptamer. Evaluation of the performance of the developed nano-modified aptasensor resulted in LOD of approximately 10 CFU mL<sup>-1</sup> with a dynamic response range from 10<sup>1</sup> to 10<sup>6</sup> CFU mL<sup>-1</sup> in 3 samples, which include milk, water and juice.</p>
<p>Zhang <italic>et al.</italic> [<xref ref-type="bibr" rid="ref53">53</xref>] reported the development of an enzyme-free electrochemical-based biosensor for the detection of <italic>Pseudomonas aeruginosa</italic>. The biosensor was fabricated using ZrMOF, which was subsequently connected with Cu<sup>2&#x002B;</sup> to form Cu-ZrMOF, possessing high catalytic activity. Moreover, a nanocomposite composed of <email>Cu-ZrMOF@Aptamer@DNA</email> served as a signal probe to catalyse the decomposition of H<sub>2</sub>O<sub>2</sub>. Furthermore, to increase the electron transfer, super P was incorporated. In order to test the biosensor using a clinical sample, a spiked urine sample is used to quantify the bacteria. The developed nanocomposite-based biosensor exhibited a wide linearity range of 10 to 10<sup>6</sup> CFU mL<sup>-1</sup>, with a LOD of 2 CFU mL<sup>-1</sup>. The biosensor has been shown to be more sensitive compared with other conventional methods.</p>
<p>The development of an electrochemiluminescence aptasensor enhanced using ruthenium(II) tris-(bipyridine) Ru(bpy)<sub>3</sub><sup>2&#x002B;</sup>-AuNPs for the detection of <italic>Listeria monocytogenes</italic> is proposed by Cui et al. [<xref ref-type="bibr" rid="ref54">54</xref>]. The aptasensor is designed based on two parts, which include an electrochemiluminescence (ECL) substrate and an ECL intensity switch. The first part revolves around the modification of the Au electrode using AuNPs and Ru(bpy)<sub>3</sub><sup>2&#x002B;</sup>, while the second part is characterized by the use of ferrocene-labelled molecular beacon aptamer (Fc-MBA), which acted as an electrochemiluminescence intensity switch, as shown in <xref ref-type="fig" rid="fig002">Figure 2</xref>. Analysis of the performance of the biosensor resulted in a LOD of 5 CFU mL<sup>-1</sup> and a linear range from 7 to 7&#x00D7;10<sup>6</sup> CFU mL<sup>-1</sup>. The electrochemiluminescence aptasensor is also tested to analyse its specificity using other bacteria, including <italic>Bacillus subtilis, Shigella flexneri, Salmonella</italic>, <italic>E. coli</italic> and <italic>S. aureus</italic>. Moreover, the aptasensor is also used to determine the bacteria in milk samples.</p>
<fig id="fig002" position="float">
<label>Figure 2.</label>
<caption><p>Electrochemiluminescence biosensing platform for <italic>Listeria monocytogenes</italic></p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ADMET-13-2799-g002.jpg" mime-subtype="jpg"/>
</fig>
<p>The development of an in situ electrochemiluminescence-based aptasensor for the detection of <italic>S. aureus</italic> is reported by Liu <italic>et al.</italic> [<xref ref-type="bibr" rid="ref34">34</xref>]. The biosensing technique relies on the hybridization between multi-DNA strands with captured DNA assembled on an electrode modified with Ru(bpy)<sub>3</sub><sup>2&#x002B;</sup>-conjugated silica NPs (RuSi NPs). Subsequently, glucose oxidase (GOD) was introduced through the functional conjugation of the enzyme with the multi-DNA, where the catalysis of GOD on glucose was accompanied by the presence of hydrogen peroxide. The ECL quenching of H<sub>2</sub>O<sub>2</sub> in the Ru(bpy)<sub>3</sub><sup>2&#x002B;</sup> system led to the quantification of the bacteria. The analysis of the aptasensor resulted in a LOD of 3.0 CFU mL<sup>-1</sup> and a linear range from 10 to 10<sup>7</sup> CFU/mL.</p>
<p>Sohouli <italic>et al.</italic> [<xref ref-type="bibr" rid="ref55">55</xref>] proposed the development of a nano-enhanced electrochemical-based aptasensor for the detection of <italic>S. aureus</italic>. The aptasensor was designed based on the modification of screen-printed carbon electrodes (SPCE) with nitrogen-doped carbon nano-onions, AuNPs, followed by self-assembly of the aptamer on the SPCE surface through covalent modification of the thiol group with gold NPs. Moreover, in order to improve the analytical parameters of the aptasensor, a carbon layer was immobilized on the electrode surface. Evaluation of the analytical performance of the aptasensor resulted in a LOD of 3 CFU mL<sup>-1</sup> and a linear range from 10 to 10<sup>8</sup> CFU mL<sup>-1</sup>.</p>
<p>Abedi <italic>et al.</italic> [<xref ref-type="bibr" rid="ref56">56</xref>] reported the development of a nano-modified impedimetric-based aptasensor for the ultra-sensitive detection of <italic>Acinetobacter baumannii</italic> bacteria. The miniaturized electrochemical biosensor leverages a label-free detection approach by exploiting EIS. The biosensing strategy revolves around the immobilization of an aptamer on the surface of CSPE modified with nanocomposite Fe<sub>3</sub>O<sub>4</sub>@SiO<sub>2</sub>@Glyoxal (Gly), which resulted in signal amplification. The evaluation of the label-free nano-modified aptasensor's performance revealed an LOD of 150 CFU/mL and a detection range of 10<sup>3</sup> to 10<sup>8</sup> CFU mL<sup>-1</sup>. The developed biosensor also yields satisfactory results when used for detecting bacteria in blood serum samples.</p>
<p>To rapidly and accurately detect <italic>E. coli</italic>, Zhong <italic>et al.</italic> [<xref ref-type="bibr" rid="ref57">57</xref>] reported the construction of a nano-enhanced electrochemiluminescence aptasensor. The advantage of the developed biosensor revolves around the use of a double aptamer recognition system, which resulted in increased accuracy. The biosensing approach revolves around the use of nano-cadmium sulphide (CdS) modified aptamer for primary labelling and subsequent immobilization of the second aptamer with a graphene/chitosan composite electrode for re-capture. Evaluation of the performance of the nano-enhanced electrochemiluminescence aptasensor resulted in a LOD of 10 CFU mL<sup>-1</sup> and a linear range from 10<sup>2</sup> to 10<sup>7</sup> CFU mL<sup>-1</sup>.</p>
<p>Yadav <italic>et al.</italic> [<xref ref-type="bibr" rid="ref58">58</xref>] reported the development of a nano-enhanced electrochemical-based aptasensor for the detection of <italic>H. pylori</italic>. The platform is designed based on 3-(aminopropyl) triethoxysilane (APTES), an organofunctional silane used to functionalize graphitic carbon nitride (g-C<sub>3</sub>N<sub>4</sub>), which is subsequently applied to screen-printed electrodes (SPE). A Cag A-specific aptamer is covalently immobilized on the <email>APTES@g-C3N4/SPE</email>. The assessment of the developed nano-enhanced electrochemical-based aptasensor demonstrated an LOD of 0.017 ng mL<sup>-1</sup>, LOQ of 0.056 ng mL<sup>-1</sup> and linear detection range from 0.1 to 160 ng mL<sup>-1</sup>. Moreover, the biosensor also exhibited a high sensitivity of 1.98 &#x03BC;A ng mL<sup>-1</sup> cm<sup>-2</sup>.</p>
<p>Jaradat <italic>et al.</italic> [<xref ref-type="bibr" rid="ref59">59</xref>] constructed an electrochemical-based immunosensor for the selective detection of the HopQ biomarker of H. pylori bacteria. The proposed biosensor was constructed by surface-modifying SPCE with multi-walled carbon nanotubes (MWCNT)-COOH and subsequently decorating it with AuNP. The nano-modified electrodes are subsequently immobilized with HopQ capture antibody grafting. To analyse the performance of the sensor, several techniques were employed, including EIS and cyclic voltammetry (CV). The result indicated that the electrochemical-based nano-modified immunosensor achieved an LOD of 2.0 pg mL<sup>-1</sup>, LOQ of 8.6 pg mL<sup>-1</sup> and linear range from 10 pg mL<sup>-1</sup> to 100 ng mL<sup>-1</sup>. The platform is also used to detect <italic>H. pylori</italic> in spiked saliva samples and further analysed using square wave voltammetry (SWV).</p>
<p>Wang <italic>et al.</italic> [<xref ref-type="bibr" rid="ref60">60</xref>] developed a one-step label-free colorimetric-based nano-enhanced immunosensor for the detection of <italic>Vibrio parahaemolyticus</italic>. The overall techniques revolve around utilization of phage-Nbs specific to V. parahaemolyticus, followed by thiolation in which the thiol group on the phage surface induce aggregation of AuNPs; hence, the interaction with <italic>V. parahaemolyticus</italic> prevents the aggregation, resulting in changes of solution colour and the optical intensity spectrum. Assessment of the biosensor based on LOD and quantitative detection limit resulted in 10<sup>4</sup> cfu/mL and 10<sup>3</sup> cfu/mL, respectively.</p>
<p>The development of electrochemical-based immunosensors modified using GO or graphene quantum dots (GQD) for rapid detection of leishmaniasis is proposed by Braz <italic>et al.</italic> [<xref ref-type="bibr" rid="ref61">61</xref>]. To detect bacteria in human and canine serum samples, the study employed different peptides that share the same recognition site but differ in their solid-binding domains. The biosensor is also evaluated against <italic>Mycobacterium tuberculosis</italic> and <italic>Mycobacterium leprae</italic>, and the immunosensor displays selective behaviour against both bacteria.</p>
<p>Hu <italic>et al.</italic> [<xref ref-type="bibr" rid="ref62">62</xref>] reported the development of an electrochemiluminescence-based approach capable of both DNA analysis and genotype classification of H. pylori. The biosensor is fabricated using AuNP and CdS as a signal switch. The strategy revolves around the use of a Y-shaped structure to capture the target DNA sequence with all the genotypes, resulting in an electrochemiluminescence signal. Subsequently, Cas9 is used to cleave the Y-shaped structure with the concomitant signal decrease. Thus, the combination of these approaches characterized by different selectivity can be used to quantify the total amount of bacterial DNA and the ratio of single-nucleotide variants (SNV). Moreover, the developed strategy is also used to conduct a large-scale screening assay on a chip. Analysis of the biosensing strategy has resulted in LOD of 8 pM and linear range from 0.01-500 nM. The selectivity of the developed biosensor toward <italic>H. pylori</italic> was compared with that of other bacteria, including <italic>E. coli, Shigella, Salmonella</italic> and <italic>S. aureus</italic>. The application of nano-modified biosensors for the detection of bacteria is summarized in <xref ref-type="table" rid="table003">Table 3</xref>.</p>
<table-wrap id="table003" position="float" orientation="portrait">
<label>Table 3.</label>
<caption><p>Application of nano-modified biosensors for the detection of bacteria</p></caption>
<table rules="all" frame="box">
<thead>
<tr>
<th align="center" valign="middle">Type of biosensors</th>
<th align="center" valign="middle">Nanomaterial</th>
<th align="center" valign="middle">Target</th>
<th align="center" valign="middle">LOD</th>
<th align="center" valign="middle">Ref.</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">Bridged Rebar Graphene (BRG)</td>
<td align="center" valign="middle"><italic>E. coli</italic></td>
<td align="center" valign="middle">101 CFU/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref52">52</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">Cu-ZrMOF</td>
<td align="center" valign="middle"><italic>Pseudomonas aeruginosa</italic></td>
<td align="center" valign="middle">2 CFU mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref53">53</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">Ru(bpy)<sub>3</sub><sup>2&#x002B;</sup>-AuNPs</td>
<td align="center" valign="middle"><italic>Listeria monocytogenes</italic></td>
<td align="center" valign="middle">5 CFU/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref54">54</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">RuSi NPs</td>
<td align="center" valign="middle"><italic>Staphylococcus aureus</italic></td>
<td align="center" valign="middle">3.0 CFU mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref34">34</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">nitrogen-doped carbon nano-onions, AuNPs</td>
<td align="center" valign="middle"><italic>Staphylococcus aureus</italic></td>
<td align="center" valign="middle">3 CFU/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref55">55</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">Fe<sub>3</sub>O<sub>4</sub>@SiO<sub>2</sub>@Glyoxal (Gly)</td>
<td align="center" valign="middle"><italic>Acinetobacter baumannii</italic></td>
<td align="center" valign="middle">150 CFU/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref56">56</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">nano-cadmium sulfide</td>
<td align="center" valign="middle"><italic>E. coli</italic></td>
<td align="center" valign="middle">10 CFU mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref57">57</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Aptasensor</td>
<td align="center" valign="middle">g-C<sub>3</sub>N<sub>4</sub></td>
<td align="center" valign="middle"><italic>H. pylori</italic></td>
<td align="center" valign="middle">0.017 ng mL<sup>-1</sup></td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref58">58</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">MWCNT-COOH and AuNP</td>
<td align="center" valign="middle"><italic>H. pylori</italic></td>
<td align="center" valign="middle">2.0 pg/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref59">59</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">AuNPs</td>
<td align="center" valign="middle"><italic>Vibrio parahaemolyticus</italic></td>
<td align="center" valign="middle">10<sup>4</sup> CFU/mL</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref60">60</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Immunosensor</td>
<td align="center" valign="middle">GO or GQD</td>
<td align="center" valign="middle"><italic>Leishmania</italic></td>
<td align="center" valign="middle">N/A</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref61">61</xref>]</td>
</tr>
<tr>
<td align="center" valign="middle">Genosensor</td>
<td align="center" valign="middle">AuNPs-CdS</td>
<td align="center" valign="middle"><italic>H. pylori</italic></td>
<td align="center" valign="middle">8pM</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="ref62">62</xref>]</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec2-7">
<title>3. 4. Application of nano-modified biosensors for the Point-of-care testing of pathogenic diseases</title>
<p>Early and timely detection of infectious diseases is crucial for effective treatment and medical cost reduction. Therefore, it is very crucial to have an ultra-sensitive, rapid, robust, selective, and specific detection approach. The healthcare sector is highly in need of miniaturized, portable or deployable detection techniques that can replace the heavy-mounted and time-consuming laboratory-based assays. One of the technologies that fulfils these criteria is POC technology. POC testing is driven by biosensors, which offer selective and sensitive analysis of biochemical recognition [<xref ref-type="bibr" rid="ref21">21</xref>,<xref ref-type="bibr" rid="ref63">63</xref>]. Biosensors offer several advantages, including portability, specificity, affordability, and rapid detection, compared to conventional techniques. There are several transduction mechanisms used in biosensing technology, dominated by electrochemical and optical approaches. Electrochemical-based biosensors (conductometric, voltammetric, potentiometric, amperometric, and impedimetric) offer several benefits, including speed, accuracy, sensitivity, practicability, and affordability [<xref ref-type="bibr" rid="ref17">17</xref>,<xref ref-type="bibr" rid="ref63">63</xref>].</p>
<p>Biosensors are regarded as ideal devices for POCT, owing to their portability. A limited number of studies have reported the development of POC-based biosensors. For example, the prospect of a nano-modified immunosensor for POCT of Ebola virus, evaluated using viral Glycoprotein diluted in PBS buffer, human serum, and plasma, is presented by Chen <italic>et al.</italic> [<xref ref-type="bibr" rid="ref23">23</xref>]. To enable POC detection, Chen <italic>et al.</italic> [<xref ref-type="bibr" rid="ref21">21</xref>] combined the assay with a portable semiconductor device, a digital display, and a minimal training requirement for end-users. This is achieved by using a cost-efficient portable UV-visible spectrometer system. Moreover, the study also developed a homemade LED-photodiode-based electronic readout system in order to enable accurate and sensitive detection. The development of a POC-based electrochemical immunosensor by Kaushik <italic>et al.</italic> [<xref ref-type="bibr" rid="ref24">24</xref>] relies on the introduction of miniaturized potentiostat (MP)-interfaced with a smartphone for rapid and online detection of ZIKV. Thus, the successful integration of nano or microelectronics in the development of miniaturized potentiostat resulted in a smart biosensor capable of POC application.</p>
</sec>
<sec id="sec2-8">
<title>3. 5. Application of nano-modified biosensors for the multiplex testing of pathogenic diseases</title>
<p>One of the key aspects of the healthcare sector that is integral for disease management is the ability to track and mitigate the spread of pathogenic diseases. This issue can be addressed through the continuous development of novel, rapid, ultrafast, ultra-sensitive, POC and multiplex testing methods that can address the diverse health needs of patients [<xref ref-type="bibr" rid="ref26 ref27">26-27</xref>]. The development of multiplex testing is transforming medical diagnostics as it enables the detection of diseases in patients presenting with multiple symptoms. It also helps medical laboratories to conserve resources compared to single-use testing. Multiplexed testing can be characterized by the use of biosensors for the detection of several variants or strains of pathogens. Multiplex testing enables the simultaneous analysis of samples for multiple pathogens. Moreover, Multiplex testing offers several benefits to the healthcare sector, as it enables hospitals to triage patients better and allocate resources.</p>
<p>Despite a plethora of studies on the application of biosensing technologies for the detection of infectious diseases, few studies have reported multiplex testing. For example, the study reported by Layqah and Eissa [<xref ref-type="bibr" rid="ref42">42</xref>] demonstrated the use of an electrochemical-based immunosensor to detect MERS-CoV and HCoV, utilising an array of carbon electrodes modified with AuNPs, as illustrated in <xref ref-type="fig" rid="fig003">Figure 3</xref>. Torrente-Rodr&#x00ED;guez <italic>et</italic> al. [<xref ref-type="bibr" rid="ref43">43</xref>] have demonstrated how SARS-CoV-2 RapidPlex can be used to detect several SARS-CoV-2 biomarkers by using 4 different WEs.</p>
<fig id="fig003" position="float">
<label>Figure 3.</label>
<caption><p>Preparation and detection process of immunosensor array chip for the detection of MERS-CoV. (a) Fabrication steps, (b) Detection process, (c) Response based on monitoring the change in the peak current at different concentrations of the antigen</p></caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="ADMET-13-2799-g003.jpg" mime-subtype="jpg"/>
</fig>
</sec>
<sec id="sec2-9">
<title>3. 6. Application of smart technology in biosensing</title>
<p>The integration of smart technology in the development of nano-modified biosensors has the potential to significantly advance the detection of pathogenic diseases by offering wireless data transfer, cloud-based data storage, and advanced data analysis. As nanotechnology contributes to the development of biosensors with higher sensitivity, specificity and fast response, smart technology enables real-time detection, remote screening, and data analysis [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref64">64</xref>]. The concept of smart biosensors is driven by cutting-edge technologies, including wearable sensors, wireless networks, and smartphone technology. Wearable biosensors are primarily used to measure physiological variables, including temperature, heart rate, blood pressure, oxygen saturation, and blood glucose levels. However, they are very limited for the detection of infectious diseases. The need for remote healthcare monitoring and real-time detection is gaining weight due to the increased likelihood of pandemics and epidemics [<xref ref-type="bibr" rid="ref65">65</xref>].</p>
<p>The development of smart nano-modified biosensors fabricated into portable or handheld devices can be used for real-time and remote detection, especially in remote or resource-limited settings. The integration of AI and IoT into nano-modified biosensors has the potential to enable the real-time tracking of pathogenic disease outbreaks. AI-driven algorithms such as ML and DL models can be used to analyse data obtained from nano-modified biosensors in order to identify underlying patterns in data and result in classification and prediction of diseases or outbreaks with high accuracy [<xref ref-type="bibr" rid="ref64">64</xref>,<xref ref-type="bibr" rid="ref66">66</xref>]. Moreover, cloud-based platforms can also be used to store a large amount of data for analysis using AI tools. Few studies have reported the implementation or integration of smart technologies for improving diagnostic capabilities. Among these studies, Torrente-Rodr&#x00ED;guez <italic>et al.</italic> [<xref ref-type="bibr" rid="ref43">43</xref>] have shown the prospect of electrochemical-based immunosensors integrated with telemedicine for the rapid and multiplexed detection of SARS-CoV-2.</p>
</sec>
</sec>
<sec id="sec1-4">
<title>4. Key findings, challenges and limitations of nanobiosensors and future directions and emerging trends</title>
<sec id="sec2-10">
<title>4. 1. Key findings</title>
<sec id="sec3-3">
<title>4. 1. 1. Nanobiosensors <italic>vs.</italic> conventional biosensors</title>
<p>Despite the advantages of conventional biosensors over laboratory bench assays in terms of portability, simplicity and ease of use, they are not without some drawbacks. Nano-modified biosensors offer several advantages over conventional biosensors. Some of these advantages include enhanced sensitivity, achieved by amplifying signals and facilitating the detection of pathogens at extremely low concentrations. Nanotechnology also contributes to improved specificity via the use of functionalized NPs designed to bind specifically to pathogens [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref17">17</xref>,<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref67">67</xref>].</p>
</sec>
<sec id="sec3-4">
<title>4. 1 .2. Electrochemical <italic>vs.</italic> optical</title>
<p>Optical and electrochemical-based approaches are the common techniques used in biosensing technology. Each type has its own strengths and limitations. Optical-based biosensors offers several advantages over electrochemical-based biosensors, especially in terms of sensitivity due to their light-based detection (fluorescence and surface plasmon resonance) which can detect small changes in wavelength, intensity or refractive index, unlike electrochemical approach which relies on electrical signals generated by redox reaction characterized by lower sensitivity especially for detection of target in complex biological samples [<xref ref-type="bibr" rid="ref68 ref69 ref70 ref71">68-71</xref>]. Optical-based biosensors also offer label-free detection where the target can be detected without the need for labelling, which also contributes to minimizing preparation time and thereby simplifying the assay [<xref ref-type="bibr" rid="ref72">72</xref>,<xref ref-type="bibr" rid="ref73">73</xref>]. Notwithstanding, optical-based biosensors are also suitable for multiplexing as they can be used to detect multiple targets by using different wavelengths compared with the electrochemical approach, which offers several limitations for multiplexing due to the need for complex electrode design, overlapping of signals or sequential measurements [<xref ref-type="bibr" rid="ref73 ref74 ref75">73-75</xref>]. Other advantages of optical-based biosensors over electrochemical types include minimal sample preparation, non-destructive and non-invasive nature, reduced susceptibility to interference, and visual readouts [<xref ref-type="bibr" rid="ref70">70</xref>,<xref ref-type="bibr" rid="ref71">71</xref>,<xref ref-type="bibr" rid="ref73">73</xref>].</p>
<p>Unlike the electrochemical transduction approach, the optical approach is limited due to its low precision for target quantification, which is crucial for detecting the severity of infection [<xref ref-type="bibr" rid="ref10">10</xref>]. ECL technique has emerged as a powerful analytical approach due to its optical setup, high versatility, excellent controllability, wide dynamic detection range, low background noise, <italic>etc</italic>. During the ECL process, electrochemically generated species on the electrode surface occur through high-energy electron transfer, forming excited states and subsequently emitting light [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref34">34</xref>]. Electrochemical-based biosensors offer several advantages, which include ease of miniaturisation, rapid response, high sensitivity and extremely low LODs, low-cost, mostly not requiring complex sample pre-treatment and potential for POCT [<xref ref-type="bibr" rid="ref63">63</xref>,<xref ref-type="bibr" rid="ref76">76</xref>]. On the other hand, the main disadvantage of electrochemical-based biosensing approach revolves around instrumental complexity compared to colorimetric techniques [<xref ref-type="bibr" rid="ref10">10</xref>]. Comparison between optical and electrochemical biosensors is summarized in <xref ref-type="table" rid="table004">Table 4</xref>.</p>
<table-wrap id="table004" position="float" orientation="portrait">
<label>Table 4.</label>
<caption><p>Comparison between optical and electrochemical biosensors</p></caption>
<table rules="all" frame="box">
<thead>
<tr>
<th align="center" valign="middle">Features</th>
<th align="center" valign="middle">Optical-based biosensors</th>
<th align="center" valign="middle">Electrochemical-based biosensors</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" valign="middle">Sensitivity</td>
<td align="center" valign="middle">Very high</td>
<td align="center" valign="middle">Moderate to high</td>
</tr>
<tr>
<td align="center" valign="middle">Specificity</td>
<td align="center" valign="middle">High</td>
<td align="center" valign="middle">High</td>
</tr>
<tr>
<td align="center" valign="middle">Portability</td>
<td align="center" valign="middle">High</td>
<td align="center" valign="middle">High</td>
</tr>
<tr>
<td align="center" valign="middle">Real-time monitoring</td>
<td align="center" valign="middle">Yes</td>
<td align="center" valign="middle">Limited</td>
</tr>
<tr>
<td align="center" valign="middle">Multiplexing</td>
<td align="center" valign="middle">Yes</td>
<td align="center" valign="middle">Limited</td>
</tr>
<tr>
<td align="center" valign="middle">Sample preparation</td>
<td align="center" valign="middle">Minimal</td>
<td align="center" valign="middle">May require sample pre-treatment</td>
</tr>
<tr>
<td align="center" valign="middle">Interference resistant</td>
<td align="center" valign="middle">High</td>
<td align="center" valign="middle">Moderate</td>
</tr>
</tbody>
</table>
</table-wrap>
</sec>
<sec id="sec3-5">
<title>4. 1. 3. Immunosensors <italic>vs.</italic> genosensors</title>
<p>Immunosensors and genosensors are the two most common biosensors used for the detection of infectious diseases. Immunosensors based on antigen-antibody interaction enable more rapid POC detection due to their simple sample preparation, lack of amplification processes; thus, immunosensors are regarded as an ideal approach and surveillance of pathogenic diseases outside clinical settings [<xref ref-type="bibr" rid="ref46">46</xref>]. Immunosensors based on antigen-antibody offer several advantages, including simplicity and rapid detection. Even though they are very attractive, they are hindered by several limitations, which include the requirement of high quantities of purified antibodies and virus titers in samples [<xref ref-type="bibr" rid="ref49">49</xref>,<xref ref-type="bibr" rid="ref77">77</xref>,<xref ref-type="bibr" rid="ref78">78</xref>].</p>
<p>In contrast to immunosensors, genosensors or genobiosensors, or DNA/RNA-based biosensors have emerged as an alternative approach for the detection of infectious diseases. Genosensors are analytical devices used for the rapid and sensitive detection of pathogens, including viruses and bacteria. Genobiosensors utilized immobilized DNA or RNA probes, which serve as biorecognition elements and hybridize with target nucleic acid [<xref ref-type="bibr" rid="ref79 ref80">79-80</xref>]. Genosensors offers several advantages, which include high specificity, simplicity, high sensitivity, rapid detection, direct analysis of complex samples, fast results acquisition and prospects for POCT. Among several classifications of biosensors, which include electrochemical, piezoelectric and optical biosensors, electrochemical-based biosensors are the most predominant types in the literature [<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref80">80</xref>].</p>
</sec>
<sec id="sec3-6">
<title>4. 1. 4. Nanomaterials</title>
<p>A plethora of studies have reported the integration of nanotechnology for enhancing the performance of biosensors. Moreover, extensive studies have emphasized AuNPs and graphene due to their desirable characteristics. For example, gold nanostructures such as AuNPs are extensively used in electrochemical-based biosensors due to their high surface area, excellent conductivity, outstanding catalytic activity and biocompatibility [<xref ref-type="bibr" rid="ref49">49</xref>,<xref ref-type="bibr" rid="ref81">81</xref>]. Thus, combining several materials to create nanocomposites has been shown to exhibit superior properties. For example, studies have shown that combining graphene with metal oxide NPs such as titanium dioxide (TiO<sub>2</sub>) improves performance due to synergistic effects [<xref ref-type="bibr" rid="ref44">44</xref>,<xref ref-type="bibr" rid="ref82">82</xref>]. Colorimetric-based biosensors have attracted interest from researchers due to their visual readout, simplicity, portability and cost-effectiveness. Among several NPs used for colorimetric assays, AuNPs are the most widely used for biosensing applications (excellent signal indicators) due to their localized surface plasmon resonance (LSPR), biocompatibility, ease of preparation and high extinction coefficient [<xref ref-type="bibr" rid="ref83 ref84">83-84</xref>].</p>
</sec>
</sec>
<sec id="sec2-11">
<title>4. 2. Challenges, limitations and prospects of nanobiosensors</title>
<p>In recent years, several techniques have been developed and applied for the rapid and sensitive detection of pathogenic organisms. Despite the progress made in recent years, the screening of pathogenic agents still requires rapid, ultrasensitive, and ultrahigh-throughput screening, as well as low-cost biosensors. The concept of ASSURED, as put forward by the WHO, recommend diagnostic devices to be affordable (A), sensitive (S), specific (S), user-friendly (U), rapid and robust (R), equipment-free (E) and deliverable (D) to those in need [<xref ref-type="bibr" rid="ref85">85</xref>].</p>
<p>Nano-modified biosensors have shown high potential for POCT and multiplexing due to their miniaturization capabilities, high sensitivity and specificity. Despite the progress recorded in the last few years, Nanobiosensors are still limited by several challenges which hinder their widespread adoption for clinical diagnosis and seemingly integration with smart technologies. One of the challenges facing nano-modified biosensors includes low sensitivity and selectivity [<xref ref-type="bibr" rid="ref11">11</xref>,<xref ref-type="bibr" rid="ref20">20</xref>]. These can be attributed to interference from complex biological samples such as blood and saliva, which contain numerous biochemical or biomolecules that can affect the performance of the biosensor. Subsequently, achieving ultra-low sensitivity or LOD for real-world samples is still challenging. Secondly, biosensors are still limited for multiplex testing due to cross-reactivity, which can lead to low accuracy and sensitivity. Despite the extensive studies conducted in the field of biosensing technology over the last 7 decades, the majority of POC-based biosensors are limited due to challenges related to automation, quantitative analysis, and interference with other biomolecules [<xref ref-type="bibr" rid="ref65">65</xref>].</p>
<p>Biosensors continue to face several limitations regarding seamless integration with smart technologies. For example, several biomarkers produce overlapping signals, which can lead to complications in terms of data interpretation [<xref ref-type="bibr" rid="ref64">64</xref>,<xref ref-type="bibr" rid="ref86">86</xref>]. Moreover, real-time data analysis and interpretation require advanced computational resources, such as hardware, software, and AI algorithms, which may not be readily available in portable devices or be prohibitively costly. Moreover, Seamless integration with IoT-based devices and smartphones for data transmission is still under development. The use of nanobiosensors integrated with smart technologies such as AI and cloud computing for data transmission and analysis requires a data protection and security system to prevent data theft and ensure confidentiality [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref66">66</xref>].</p>
<p>Another challenge facing nano-modified biosensors revolves around fabrication and scalability, which often requires complex manufacturing processes and sophisticated techniques. Complex manufacturing processes have been shown to increase production costs and are challenging to scale for mass production [<xref ref-type="bibr" rid="ref20">20</xref>,<xref ref-type="bibr" rid="ref87">87</xref>,<xref ref-type="bibr" rid="ref88">88</xref>]. To develop ideal nano-modified biosensors integrated with smart technologies for POCT and multiplexing, several limitations must be addressed. Exploring other nanomaterials or their combinations (such as nanocomposites) can improve sensitivity, biocompatibility and durability [<xref ref-type="bibr" rid="ref89 ref90">89-90</xref>]. Moreover, exploring other novel surface functionalization techniques can improve selectivity and minimize interference [<xref ref-type="bibr" rid="ref91 ref92">91-92</xref>]. Another direction involves the development of nano-modified biosensors integrated with microfluidic systems for automated sample handling and analysis. Thus, the development of microfluidic and Lab-on-Chip systems will enable POCT [<xref ref-type="bibr" rid="ref93 ref94 ref95 ref96">93-96</xref>].</p>
<p>The continuous integration of smart technologies, such as AI-driven systems for real-time data processing, including noise reduction and analysis through pattern recognition, classification, and interpretation, can improve accuracy. Notwithstanding, seamless integration of wireless and IoT systems will enhance connectivity and data sharing with other devices such as smartphones and cloud systems for remote monitoring and surveillance [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref29">29</xref>,<xref ref-type="bibr" rid="ref64">64</xref>,<xref ref-type="bibr" rid="ref66">66</xref>,<xref ref-type="bibr" rid="ref97">97</xref>].</p>
<p>While nano-modified biosensors have shown great promise for POCT and multiplex testing, however, overcoming current challenges and limitations requires continuous research in the field of material science, engineering, data analytics, confidentiality, data protection, and regulatory compliance. Thus, by addressing these challenges, nanobiosensors can become a cornerstone of next-generation diagnostic devices, enabling smarter, faster, accurate and more accessible healthcare solutions.</p>
</sec>
</sec>
<sec id="sec1-5">
<title>5. Conclusion</title>
<p>Infectious diseases continue to cause global health challenges. Fast and early detection of pathogenic diseases is crucial for preventing outbreaks, appropriate treatment and reducing costs. For clinical diagnosis of pathogenic diseases, the medical field relies on immunoassays, PCR and reverse transcription-polymerase chain reaction (RT-PCR). Despite the high dependency on these approaches, they are hindered by several limitations. Immunoassays are limited by their low sensitivity, whereas PCR-based methods are more sensitive and specific; however, they also have limitations, including false-positive results, the need for trained experts, susceptibility to contamination, and high costs. Biosensors have become the ideal diagnosis approach due to their sensitivity, portability, specificity and potential for POCT compared with conventional approaches.</p>
<p>The continued transformation in nanotechnology has led to their integration in biosensing applications. Several nanomaterials have been employed to fabricate biosensors, including metal NPs, polymeric nanomaterials, and nanocomposites. The integration of nanotechnology in biosensing applications has been shown to amplify the detection signal. Based on the findings from this review, biosensors offer several advantages over conventional approaches, with LOD ranging between nanomolar to attomolar concentration and time response ranging from 1-3 hours. Few studies have reported achieving lower LOD; however, their strategies are quite complex, extensive and require many steps, which increase time, process and cost. The integration of smart technologies in nanobiosensors has been shown to offer several benefits, which include high accuracy, faster detection and prediction. Smart technologies are crucial for early detection, surveillance, prevention of outbreaks, and effective treatment of pathogenic diseases.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="conflict"><p><italic><bold>Conflict of interest</bold>: We declared no conflicts of interest</italic></p></fn>
</fn-group>
<ref-list>
<title>References</title>
<ref id="ref1"><label>1.</label> <mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Sigerist</surname><given-names>H.E.</given-names></name></person-group> <source>Civilization and disease.</source> <publisher-name>Cornell University Press</publisher-name>, <publisher-loc>Ithaca, NY, USA</publisher-loc>, <year>2018</year>. <comment>ISBN 9781501723452. <ext-link ext-link-type="uri" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://books.google.rs/books?id=ihdiDwAAQBAJ&#x0026;printsec=frontcover#v=onepage&#x0026;q&#x0026;f=false">https://books.google.rs/books?id=ihdiDwAAQBAJ&#x0026;printsec=frontcover#v=onepage&#x0026;q&#x0026;f=false</ext-link></comment></mixed-citation></ref>
<ref id="ref2"><label>2.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mukherjee</surname> <given-names>S.</given-names></name></person-group>. <article-title>Emerging infectious diseases: Epidemiological perspective</article-title>. <source>Indian Journal of Dermatology</source> <volume>62</volume> (<year>2017</year>) <fpage>459</fpage>-<lpage>467</lpage>. <comment>https://doi.org/10.4103/ijd.IJD_379_17</comment> <pub-id pub-id-type="doi">10.4103/ijd.IJD_379_17</pub-id></mixed-citation></ref>
<ref id="ref3"><label>3.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bloom</surname> <given-names>D.E.</given-names></name><name><surname>Cadarette</surname> <given-names>D.</given-names></name></person-group>. <article-title>Infectious disease threats in the twenty-first century: strengthening the global response</article-title>. <source>Frontiers in Immunology</source> <volume>10</volume> (<year>2019</year>) <fpage>549</fpage>. <comment>https://doi.org/10.3389/fimmu.2019.00549</comment> <pub-id pub-id-type="doi">10.3389/fimmu.2019.00549</pub-id></mixed-citation></ref>
<ref id="ref4"><label>4.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jutel</surname> <given-names>A.</given-names></name></person-group>. <article-title>Classification, disease, and diagnosis</article-title>. <source>Perspectives in Biology and Medicine</source> <volume>54</volume> (<year>2011</year>) <fpage>189</fpage>-<lpage>205</lpage>. <comment>https://doi.org/10.1353/pbm.2011.0015</comment> <pub-id pub-id-type="doi">10.1353/pbm.2011.0015</pub-id></mixed-citation></ref>
<ref id="ref5"><label>5.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Moreno-Ibarra</surname> <given-names>M.A.</given-names></name><name><surname>Villuendas-Rey</surname> <given-names>Y.</given-names></name><name><surname>Lytras</surname> <given-names>M.D.</given-names></name><name><surname>Y&#x00E1;&#x00F1;ez-M&#x00E1;rquez</surname> <given-names>C.</given-names></name><name><surname>Salgado-Ram&#x00ED;rez</surname><given-names>J.C.</given-names></name></person-group>. <article-title>Classification of diseases using machine learning algorithms: A comparative study</article-title>. <source>Mathematics</source> <volume>9</volume> (<year>2021</year>) <fpage>1817</fpage>. <comment>https://doi.org/10.3390/math9151817</comment> <pub-id pub-id-type="doi">10.3390/math9151817</pub-id></mixed-citation></ref>
<ref id="ref6"><label>6.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hotez</surname> <given-names>P.J.</given-names></name></person-group>. <article-title>The rise or fall of neglected tropical diseases in East Asia Pacific</article-title>. <source>Acta Tropica</source> <volume>202</volume> (<year>2020</year>) <fpage>105182</fpage>. <comment>https://doi.org/10.1016/j.actatropica.2019.105182</comment> <pub-id pub-id-type="doi">10.1016/j.actatropica.2019.105182</pub-id></mixed-citation></ref>
<ref id="ref7"><label>7.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kerry</surname> <given-names>R.G.</given-names></name><name><surname>Ukhurebor</surname> <given-names>K.E.</given-names></name><name><surname>Kumari</surname> <given-names>S.</given-names></name><name><surname>Maurya</surname> <given-names>G.K.</given-names></name><name><surname>Patra</surname> <given-names>S.</given-names></name><name><surname>Panigrahi</surname> <given-names>B.</given-names></name><name><surname>Majhi</surname> <given-names>S.</given-names></name><name><surname>Rout</surname> <given-names>J.R.</given-names></name><name><surname>del Pilar Rodriguez-Torres</surname> <given-names>M.</given-names></name><name><surname>Das</surname> <given-names>G.</given-names></name><name><surname>Shin</surname> <given-names>H.S.</given-names></name></person-group>. <article-title>A comprehensive review on the applications of nano-biosensor-based approaches for non-communicable and communicable disease detection</article-title>. <source>Biomaterials Science</source> <volume>9</volume> (<year>2021</year>) <fpage>3576</fpage>-<lpage>602</lpage>. <comment>https://doi.org/10.1039/D0BM02164D</comment> <pub-id pub-id-type="doi">10.1039/D0BM02164D</pub-id></mixed-citation></ref>
<ref id="ref8"><label>8.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Morens</surname> <given-names>D.M.</given-names></name><name><surname>Fauci</surname> <given-names>A.S.</given-names></name></person-group>. <article-title>Emerging infectious diseases: threats to human health and global stability</article-title>. <source>PLoS Pathogens</source> <volume>9</volume> (<year>2013</year>) <fpage>e1003467</fpage>. <comment>https://doi.org/10.1371/journal.ppat.1003467</comment> <pub-id pub-id-type="doi">10.1371/journal.ppat.1003467</pub-id></mixed-citation></ref>
<ref id="ref9"><label>9.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Baker</surname> <given-names>R.E.</given-names></name><name><surname>Mahmud</surname> <given-names>A.S.</given-names></name><name><surname>Miller</surname> <given-names>I.F.</given-names></name><name><surname>Rajeev</surname> <given-names>M.</given-names></name><name><surname>Rasambainarivo</surname> <given-names>F.</given-names></name><name><surname>Rice</surname> <given-names>B.L.</given-names></name><name><surname>Takahashi</surname> <given-names>S.</given-names></name><name><surname>Tatem</surname> <given-names>A.J.</given-names></name><name><surname>Wagner</surname> <given-names>C.E.</given-names></name><name><surname>Wang</surname> <given-names>L.F.</given-names></name><name><surname>Wesolowski</surname> <given-names>A.</given-names></name></person-group>. <article-title>Infectious disease in an era of global change</article-title>. <source>Nature Reviews Microbiology</source> <volume>20</volume> (<year>2022</year>) <fpage>193</fpage>-<lpage>205</lpage>. <comment>https://doi.org/10.1038/s41579-021-00639-z</comment> <pub-id pub-id-type="doi">10.1038/s41579-021-00639-z</pub-id></mixed-citation></ref>
<ref id="ref10"><label>10.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Brazaca</surname> <given-names>L.C.</given-names></name><name><surname>Dos Santos</surname> <given-names>P.L.</given-names></name><name><surname>de Oliveira</surname> <given-names>P.R.</given-names></name><name><surname>Rocha</surname> <given-names>D.P.</given-names></name><name><surname>Stefano</surname> <given-names>J.S.</given-names></name><name><surname>Kalinke</surname> <given-names>C.</given-names></name><name><surname>Munoz</surname> <given-names>R.A.</given-names></name><name><surname>Bonacin</surname> <given-names>J.A.</given-names></name><name><surname>Janegitz</surname> <given-names>B.C.</given-names></name><name><surname>Carrilho</surname> <given-names>E.</given-names></name></person-group>. <article-title>Biosensing strategies for the electrochemical detection of viruses and viral diseases&#x2013;A review</article-title>. <source>Analytica Chimica Acta</source> <volume>1159</volume> (<year>2021</year>) <fpage>338384</fpage>. <comment>https://doi.org/10.1016/j.aca.2021.338384</comment> <pub-id pub-id-type="doi">10.1016/j.aca.2021.338384</pub-id></mixed-citation></ref>
<ref id="ref11"><label>11.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Irkham</surname> <given-names>I.</given-names></name><name><surname>Ibrahim</surname> <given-names>A.U.</given-names></name><name><surname>Pwavodi</surname> <given-names>P.C.</given-names></name><name><surname>Al-Turjman</surname> <given-names>F.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>Smart graphene-based electrochemical nanobiosensor for clinical diagnosis</article-title>. <source>Sensors</source> <volume>23</volume> (<year>2023</year>) <fpage>2240</fpage>. <comment>https://doi.org/10.3390/s23042240</comment> <pub-id pub-id-type="doi">10.3390/s23042240</pub-id></mixed-citation></ref>
<ref id="ref12"><label>12.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dhahi</surname> <given-names>T.S.</given-names></name><name><surname>Dafhalla</surname> <given-names>A.K.</given-names></name><name><surname>Saad</surname> <given-names>S.A.</given-names></name><name><surname>Zayan</surname> <given-names>D.M.</given-names></name><name><surname>Ahmed</surname> <given-names>A.E.</given-names></name><name><surname>Elobaid</surname> <given-names>M.E.</given-names></name><name><surname>Adam</surname> <given-names>T.</given-names></name><name><surname>Gopinath</surname> <given-names>S.C.</given-names></name></person-group>. <article-title>The importance, benefits, and future of nanobiosensors for infectious diseases</article-title>. <source>Biotechnology and Applied Biochemistry</source> <volume>71</volume> (<year>2024</year>) <fpage>429</fpage>-<lpage>45</lpage>. <comment>https://doi.org/10.1002/bab.2550</comment> <pub-id pub-id-type="doi">10.1002/bab.2550</pub-id></mixed-citation></ref>
<ref id="ref13"><label>13.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bhatia</surname> <given-names>D.</given-names></name><name><surname>Paul</surname> <given-names>S.</given-names></name><name><surname>Acharjee</surname> <given-names>T.</given-names></name><name><surname>Ramachairy</surname> <given-names>S.S.</given-names></name></person-group>. <article-title>Biosensors and their widespread impact on human health</article-title>. <source>Sensors International</source> <volume>5</volume> (<year>2024</year>) <fpage>100257</fpage>. <comment>https://doi.org/10.1016/j.sintl.2023.100257</comment> <pub-id pub-id-type="doi">10.1016/j.sintl.2023.100257</pub-id></mixed-citation></ref>
<ref id="ref14"><label>14.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ibrahim</surname> <given-names>A.U.</given-names></name><name><surname>Al-Turjman</surname> <given-names>F.</given-names></name><name><surname>Sa&#x2019;id</surname> <given-names>Z.</given-names></name><name><surname>Ozsoz</surname> <given-names>M.</given-names></name></person-group>. <article-title>Futuristic CRISPR-based biosensing in the cloud and internet of things era: an overview</article-title>. <source>Multimedia Tools and Applications</source> <volume>81</volume> (<year>2022</year>) <fpage>35143</fpage>-<lpage>71</lpage>. <comment>https://doi.org/10.1007/s11042-020-09010-5</comment> <pub-id pub-id-type="doi">10.1007/s11042-020-09010-5</pub-id></mixed-citation></ref>
<ref id="ref15"><label>15.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nakhjavani</surname> <given-names>S.A.</given-names></name><name><surname>Mirzajani</surname> <given-names>H.</given-names></name><name><surname>Cararra</surname> <given-names>S.</given-names></name><name><surname>Onba&#x015F;l&#x0131;</surname><given-names>M.C.</given-names></name></person-group>. <article-title>Advances in biosensor technologies for infectious diseases detection</article-title>. <source>TrAC Trends in Analytical Chemistry</source> <volume>180</volume> (<year>2024</year>) <fpage>117979</fpage>. <comment>https://doi.org/10.1016/j.trac.2024.117979</comment> <pub-id pub-id-type="doi">10.1016/j.trac.2024.117979</pub-id></mixed-citation></ref>
<ref id="ref16"><label>16.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ibrahim</surname> <given-names>A.U.</given-names></name><name><surname>Nwekwo</surname> <given-names>C.W.</given-names></name><name><surname>Pwavodi</surname> <given-names>P.C.</given-names></name><name><surname>Zakiyyah</surname> <given-names>S.N.</given-names></name><name><surname>Ozsoz</surname> <given-names>M.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>From nanotechnology to AI: The next generation of CRISPR-based smart biosensors for infectious disease detection</article-title>. <source>Microchemical Journal</source> <volume>208</volume> (<year>2024</year>) <fpage>112577</fpage>. <comment>https://doi.org/10.1016/j.microc.2024.112577</comment> <pub-id pub-id-type="doi">10.1016/j.microc.2024.112577</pub-id></mixed-citation></ref>
<ref id="ref17"><label>17.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Noah</surname> <given-names>N.M.</given-names></name><name><surname>Ndangili</surname> <given-names>P.M.</given-names></name></person-group>. <article-title>Current trends of nanobiosensors for point-of-care diagnostics</article-title>. <source>Journal of Analytical Methods in Chemistry</source> <volume>2019</volume> (<year>2019</year>) <fpage>2179718</fpage>. <comment>https://doi.org/10.1155/2019/2179718</comment> <pub-id pub-id-type="doi">10.1155/2019/2179718</pub-id></mixed-citation></ref>
<ref id="ref18"><label>18.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Singh</surname> <given-names>N.</given-names></name><name><surname>Dkhar</surname> <given-names>D.S.</given-names></name><name><surname>Chandra</surname> <given-names>P.</given-names></name><name><surname>Azad</surname> <given-names>U.P.</given-names></name></person-group>. <article-title>Nanobiosensors design using 2D materials: Implementation in infectious and fatal disease diagnosis</article-title>. <source>Biosensors</source> <volume>13</volume> (<year>2023</year>) <fpage>166</fpage>. <comment>https://doi.org/10.3390/bios13020166</comment> <pub-id pub-id-type="doi">10.3390/bios13020166</pub-id></mixed-citation></ref>
<ref id="ref19"><label>19.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rios</surname> <given-names>T.B.</given-names></name><name><surname>Maximiano</surname> <given-names>M.R.</given-names></name><name><surname>Feitosa</surname> <given-names>G.C.</given-names></name><name><surname>Malmsten</surname> <given-names>M.</given-names></name><name><surname>Franco</surname> <given-names>O.L.</given-names></name></person-group>. <article-title>Nanosensors for animal infectious disease detection</article-title>. <source>Sensing and Bio-Sensing Research</source> <volume>43</volume> (<year>2024</year>) <fpage>100622</fpage>. <comment>https://doi.org/10.1016/j.sbsr.2024.100622</comment> <pub-id pub-id-type="doi">10.1016/j.sbsr.2024.100622</pub-id></mixed-citation></ref>
<ref id="ref20"><label>20.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kulkarni</surname> <given-names>M.B.</given-names></name><name><surname>Ayachit</surname> <given-names>N.H.</given-names></name><name><surname>Aminabhavi</surname> <given-names>T.M.</given-names></name></person-group>. <article-title>Recent advancements in nanobiosensors: current trends, challenges, applications, and future scope</article-title>. <source>Biosensors</source> <volume>12</volume> (<year>2022</year>) <fpage>892</fpage>. <comment>https://doi.org/10.3390/bios12100892</comment> <pub-id pub-id-type="doi">10.3390/bios12100892</pub-id></mixed-citation></ref>
<ref id="ref21"><label>21.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>C.</given-names></name><name><surname>Liu</surname> <given-names>M.</given-names></name><name><surname>Wang</surname> <given-names>Z.</given-names></name><name><surname>Li</surname> <given-names>S.</given-names></name><name><surname>Deng</surname> <given-names>Y.</given-names></name><name><surname>He</surname> <given-names>N.</given-names></name></person-group>. <article-title>Point-of-care diagnostics for infectious diseases: From methods to devices</article-title>. <source>Nano Today</source> <volume>37</volume> (<year>2021</year>) <fpage>101092</fpage>. <comment>https://doi.org/10.1016/j.nantod.2021.101092</comment> <pub-id pub-id-type="doi">10.1016/j.nantod.2021.101092</pub-id></mixed-citation></ref>
<ref id="ref22"><label>22.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>F.E.</given-names></name><name><surname>Lee</surname> <given-names>P.W.</given-names></name><name><surname>Trick</surname> <given-names>A.Y.</given-names></name><name><surname>Park</surname> <given-names>J.S.</given-names></name><name><surname>Chen</surname> <given-names>L.</given-names></name><name><surname>Shah</surname> <given-names>K.</given-names></name><name><surname>Mostafa</surname> <given-names>H.</given-names></name><name><surname>Carroll</surname> <given-names>K.C.</given-names></name><name><surname>Hsieh</surname> <given-names>K.</given-names></name><name><surname>Wang</surname> <given-names>T.H.</given-names></name></person-group>. <article-title>Point-of-care CRISPR-Cas-assisted SARS-CoV-2 detection in an automated and portable droplet magnetofluidic device</article-title>. <source>Biosensors and Bioelectronics</source> <volume>190</volume> (<year>2021</year>) <fpage>113390</fpage>. <comment>https://doi.org/10.1016/j.bios.2021.113390</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2021.113390</pub-id></mixed-citation></ref>
<ref id="ref23"><label>23.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>Y.</given-names></name><name><surname>Ren</surname> <given-names>R.</given-names></name><name><surname>Pu</surname> <given-names>H.</given-names></name><name><surname>Guo</surname> <given-names>X.</given-names></name><name><surname>Chang</surname> <given-names>J.</given-names></name><name><surname>Zhou</surname> <given-names>G.</given-names></name><name><surname>Mao</surname> <given-names>S.</given-names></name><name><surname>Kron</surname> <given-names>M.</given-names></name><name><surname>Chen</surname> <given-names>J.</given-names></name></person-group>. <article-title>Field-effect transistor biosensor for rapid detection of Ebola antigen</article-title>. <source>Scientific Reports</source> <volume>7</volume> (<year>2017</year>) <fpage>10974</fpage>. <comment>https://doi.org/10.1038/s41598-017-11387-7</comment> <pub-id pub-id-type="doi">10.1038/s41598-017-11387-7</pub-id></mixed-citation></ref>
<ref id="ref24"><label>24.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kaushik</surname> <given-names>A.</given-names></name><name><surname>Mujawar</surname> <given-names>M.A.</given-names></name></person-group>. <article-title>Point of care sensing devices: better care for everyone</article-title>. <source>Sensors</source> <volume>18</volume> (<year>2018</year>) <fpage>4303</fpage>. <comment>https://doi.org/10.3390/s18124303</comment> <pub-id pub-id-type="doi">10.3390/s18124303</pub-id></mixed-citation></ref>
<ref id="ref25"><label>25.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Williams</surname> <given-names>F.</given-names></name><name><surname>Oke</surname> <given-names>A.</given-names></name><name><surname>Zachary</surname> <given-names>I.</given-names></name></person-group>. <article-title>Public health delivery in the information age: the role of informatics and technology</article-title>. <source>Perspectives in Public Health</source> <volume>139</volume> (<year>2019</year>) <fpage>236</fpage>-<lpage>54</lpage>. <comment>https://doi.org/10.1177/1757913918802308</comment> <pub-id pub-id-type="doi">10.1177/1757913918802308</pub-id></mixed-citation></ref>
<ref id="ref26"><label>26.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shu</surname> <given-names>B.</given-names></name><name><surname>Kirby</surname> <given-names>M.K.</given-names></name><name><surname>Davis</surname> <given-names>W.G.</given-names></name><name><surname>Warnes</surname> <given-names>C.</given-names></name><name><surname>Liddell</surname> <given-names>J.</given-names></name><name><surname>Liu</surname> <given-names>J.</given-names></name><name><surname>Wu</surname> <given-names>K.H.</given-names></name><name><surname>Hassell</surname> <given-names>N.</given-names></name><name><surname>Benitez</surname> <given-names>A.J.</given-names></name><name><surname>Wilson</surname> <given-names>M.M.</given-names></name><name><surname>Keller</surname> <given-names>M.W.</given-names></name></person-group>. <article-title>Multiplex real-time reverse transcription PCR for influenza A virus, influenza B virus, and severe acute respiratory syndrome coronavirus 2</article-title>. <source>Emerging infectious diseases</source> <volume>27</volume> (<year>2021</year>) <fpage>1821</fpage>. <comment>https://doi.org/10.3201/eid2707.210462</comment> <pub-id pub-id-type="doi">10.3201/eid2707.210462</pub-id></mixed-citation></ref>
<ref id="ref27"><label>27.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Otoo</surname> <given-names>J.A.</given-names></name><name><surname>Schlappi</surname> <given-names>T.S.</given-names></name></person-group>. <article-title>REASSURED multiplex diagnostics: a critical review and forecast</article-title>. <source>Biosensors</source> <volume>12</volume> (<year>2022</year>) <fpage>124</fpage>. <comment>https://doi.org/10.3390/bios12020124</comment> <pub-id pub-id-type="doi">10.3390/bios12020124</pub-id></mixed-citation></ref>
<ref id="ref28"><label>28.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Palenzuela</surname> <given-names>C.L.</given-names></name><name><surname>Pumera</surname> <given-names>M.</given-names></name></person-group>. <article-title>(Bio) Analytical chemistry enabled by 3D printing: Sensors and biosensors</article-title>. <source>TrAC Trends in Analytical Chemistry</source> <volume>103</volume> (<year>2018</year>) <fpage>110</fpage>-<lpage>8</lpage>. <comment>https://doi.org/10.1016/j.trac.2018.03.016</comment> <pub-id pub-id-type="doi">10.1016/j.trac.2018.03.016</pub-id></mixed-citation></ref>
<ref id="ref29"><label>29.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pateraki</surname> <given-names>M.</given-names></name><name><surname>Fysarakis</surname> <given-names>K.</given-names></name><name><surname>Sakkalis</surname> <given-names>V.</given-names></name><name><surname>Spanoudakis</surname> <given-names>G.</given-names></name><name><surname>Varlamis</surname> <given-names>I.</given-names></name><name><surname>Maniadakis</surname> <given-names>M.</given-names></name><name><surname>Lourakis</surname> <given-names>M.</given-names></name><name><surname>Ioannidis</surname> <given-names>S.</given-names></name><name><surname>Cummins</surname> <given-names>N.</given-names></name><name><surname>Schuller</surname> <given-names>B.</given-names></name><name><surname>Loutsetis</surname> <given-names>E.</given-names></name></person-group>. <article-title>Biosensors and Internet of Things in smart healthcare applications: Challenges and opportunities</article-title>. <source>Wearable and Implantable Medical Devices</source> (<year>2020</year>) <fpage>25</fpage>-<lpage>53</lpage>. <comment>https://doi.org/10.1016/B978-0-12-815369-7.00002-1</comment> <pub-id pub-id-type="doi">10.1016/B978-0-12-815369-7.00002-1</pub-id></mixed-citation></ref>
<ref id="ref30"><label>30.</label> <mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Boutayeb</surname> <given-names>A.</given-names></name></person-group>, <article-title>The Burden of Communicable and Non-Communicable Diseases in Developing Countries</article-title>, in <source>Handbook of Disease Burdens and Quality of Life Measures</source>, <person-group person-group-type="editor"><name><surname>Preedy</surname><given-names>V.R.</given-names></name><name><surname>Watson</surname><given-names>R.R.</given-names></name></person-group> Eds., <publisher-name>Springer</publisher-name>, <publisher-loc>New York, NY, USA</publisher-loc>, <year>2010</year>, p. <fpage>16</fpage>. <comment>https://doi.org/10.1007/978-0-387-78665-0_32</comment> <pub-id pub-id-type="doi">10.1007/978-0-387-78665-0_32</pub-id></mixed-citation></ref>
<ref id="ref31"><label>31.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Finlay</surname> <given-names>B.B.</given-names></name><collab>CIFAR Humans</collab></person-group>. <article-title>Are noncommunicable diseases communicable?</article-title> <source>Science</source> <volume>367</volume> (<year>2020</year>) <fpage>250</fpage>-<lpage>1</lpage>. <comment>https://doi.org/10.1126/science.aaz3834</comment> <pub-id pub-id-type="doi">10.1126/science.aaz3834</pub-id></mixed-citation></ref>
<ref id="ref32"><label>32.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dronina</surname> <given-names>J.</given-names></name><name><surname>Samukaite-Bubniene</surname> <given-names>U.</given-names></name><name><surname>Ramanavicius</surname> <given-names>A.</given-names></name></person-group>. <article-title>Advances and insights in the diagnosis of viral infections</article-title>. <source>Journal of Nanobiotechnology</source> (<year>2021</year>) <fpage>1</fpage>-<lpage>23</lpage>. <comment>https://doi.org/10.1186/s12951-021-01081-2</comment> <pub-id pub-id-type="doi">10.1186/s12951-021-01081-2</pub-id></mixed-citation></ref>
<ref id="ref33"><label>33.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cohen</surname> <given-names>F.S.</given-names></name></person-group>. <article-title>How viruses invade cells</article-title>. <source>Biophysical Journal</source> <volume>110</volume> (<year>2016</year>) <fpage>1028</fpage>-<lpage>32</lpage>. <comment>https://doi.org/10.1016/j.bpj.2016.02.006</comment> <pub-id pub-id-type="doi">10.1016/j.bpj.2016.02.006</pub-id></mixed-citation></ref>
<ref id="ref34"><label>34.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname> <given-names>S.</given-names></name><name><surname>Li</surname> <given-names>Q.</given-names></name><name><surname>Yang</surname> <given-names>H.</given-names></name><name><surname>Wang</surname> <given-names>P.</given-names></name><name><surname>Miao</surname> <given-names>X.</given-names></name><name><surname>Feng</surname> <given-names>Q.</given-names></name></person-group>. <article-title>An in situ quenching electrochemiluminescence biosensor amplified with aptamer recognition-induced multi-DNA release for sensitive detection of pathogenic bacteria</article-title>. <source>Biosensors and Bioelectronics</source> <volume>196</volume> (<year>2022</year>) <fpage>113744</fpage>. <comment>https://doi.org/10.1016/j.bios.2021.113744</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2021.113744</pub-id></mixed-citation></ref>
<ref id="ref35"><label>35.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zakiyyah</surname> <given-names>S.N.</given-names></name><name><surname>Ibrahim</surname> <given-names>A.U.</given-names></name><name><surname>Babiker</surname> <given-names>M.S.</given-names></name><name><surname>Gaffar</surname> <given-names>S.</given-names></name><name><surname>Ozsoz</surname> <given-names>M.</given-names></name><name><surname>Zein</surname> <given-names>M.I.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>Detection of tropical diseases caused by mosquitoes using CRISPR-based biosensors</article-title>. <source>Tropical Medicine and Infectious Disease</source> <volume>7</volume> (<year>2022</year>) <fpage>309</fpage>. <comment>https://doi.org/10.3390/tropicalmed7100309</comment> <pub-id pub-id-type="doi">10.3390/tropicalmed7100309</pub-id></mixed-citation></ref>
<ref id="ref36"><label>36.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Abebe</surname> <given-names>E.</given-names></name><name><surname>Gugsa</surname> <given-names>G.</given-names></name><name><surname>Ahmed</surname> <given-names>M.</given-names></name></person-group>. <article-title>Review on major food-borne zoonotic bacterial pathogens</article-title>. <source>Journal of Tropical Medicine</source> <volume>2020</volume> (<year>2020</year>) <fpage>4674235</fpage>. <comment>https://doi.org/10.1155/2020/4674235</comment> <pub-id pub-id-type="doi">10.1155/2020/4674235</pub-id></mixed-citation></ref>
<ref id="ref37"><label>37.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pitt</surname> <given-names>T.L.</given-names></name><name><surname>Barer</surname> <given-names>M.R.</given-names></name></person-group>. <article-title>Classification, identification and typing of micro-organisms</article-title>. <source>Medical Microbiology</source> <volume>24</volume> (<year>2012</year>) <fpage>24</fpage>-<lpage>38</lpage>. <comment>https://doi.org/10.1016/B978-0-7020-4089-4.00018-4</comment> <pub-id pub-id-type="doi">10.1016/B978-0-7020-4089-4.00018-4</pub-id></mixed-citation></ref>
<ref id="ref38"><label>38.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pavlova</surname> <given-names>M.D.</given-names></name><name><surname>Asaturova</surname> <given-names>A.M.</given-names></name><name><surname>Kozitsyn</surname> <given-names>A.E.</given-names></name></person-group>. <article-title>Bacterial cell shape: Some features of ultrastructure, evolution, and ecology</article-title>. <source>Biology Bulletin Reviews</source> <volume>12</volume> (<year>2022</year>) <fpage>254</fpage>-<lpage>65</lpage>. <comment>https://doi.org/10.1134/S2079086422030070</comment> <pub-id pub-id-type="doi">10.1134/S2079086422030070</pub-id></mixed-citation></ref>
<ref id="ref39"><label>39.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mai-Prochnow</surname> <given-names>A.</given-names></name><name><surname>Clauson</surname> <given-names>M.</given-names></name><name><surname>Hong</surname> <given-names>J.</given-names></name><name><surname>Murphy</surname> <given-names>A.B.</given-names></name></person-group>. <article-title>Gram positive and Gram-negative bacteria differ in their sensitivity to cold plasma</article-title>. <source>Scientific Reports</source> <volume>6</volume> (<year>2016</year>) <fpage>38610</fpage>. <comment>https://doi.org/10.1038/srep38610</comment> <pub-id pub-id-type="doi">10.1038/srep38610</pub-id></mixed-citation></ref>
<ref id="ref40"><label>40.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zang</surname> <given-names>F.</given-names></name><name><surname>Su</surname> <given-names>Z.</given-names></name><name><surname>Zhou</surname> <given-names>L.</given-names></name><name><surname>Konduru</surname> <given-names>K.</given-names></name><name><surname>Kaplan</surname> <given-names>G.</given-names></name><name><surname>Chou</surname> <given-names>S.Y.</given-names></name></person-group>. <article-title>Ultrasensitive Ebola virus antigen sensing via 3D nanoantenna arrays</article-title>. <source>Advanced Materials</source> <volume>31</volume> (<year>2019</year>) <fpage>1902331</fpage>. <comment>https://doi.org/10.1002/adma.201902331</comment> <pub-id pub-id-type="doi">10.1002/adma.201902331</pub-id></mixed-citation></ref>
<ref id="ref41"><label>41.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chowdhury</surname> <given-names>A.D.</given-names></name><name><surname>Takemura</surname> <given-names>K.</given-names></name><name><surname>Li</surname> <given-names>T.C.</given-names></name><name><surname>Suzuki</surname> <given-names>T.</given-names></name><name><surname>Park</surname> <given-names>E.Y.</given-names></name></person-group>. <article-title>Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection</article-title>. <source>Nature Communications</source> <volume>10</volume> (<year>2019</year>) <fpage>3737</fpage>. <comment>https://doi.org/10.1038/s41467-019-11644-5</comment> <pub-id pub-id-type="doi">10.1038/s41467-019-11644-5</pub-id></mixed-citation></ref>
<ref id="ref42"><label>42.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Layqah</surname> <given-names>L.A.</given-names></name><name><surname>Eissa</surname> <given-names>S.</given-names></name></person-group>. <article-title>An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes</article-title>. <source>Microchimica Acta</source> <volume>186</volume> (<year>2019</year>) <fpage>224</fpage>. <comment>https://doi.org/10.1007/s00604-019-3345-5</comment> <pub-id pub-id-type="doi">10.1007/s00604-019-3345-5</pub-id></mixed-citation></ref>
<ref id="ref43"><label>43.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Torrente-Rodr&#x00ED;guez</surname> <given-names>R.M.</given-names></name><name><surname>Lukas</surname> <given-names>H.</given-names></name><name><surname>Tu</surname> <given-names>J.</given-names></name><name><surname>Min</surname> <given-names>J.</given-names></name><name><surname>Yang</surname> <given-names>Y.</given-names></name><name><surname>Xu</surname> <given-names>C.</given-names></name><name><surname>Rossiter</surname> <given-names>H.B.</given-names></name><name><surname>Gao</surname> <given-names>W.</given-names></name></person-group>. <article-title>SARS-CoV-2 RapidPlex: a graphene-based multiplexed telemedicine platform for rapid and low-cost COVID-19 diagnosis and monitoring</article-title>. <source>Matter</source> <volume>3</volume> (<year>2020</year>) <fpage>1981</fpage>-<lpage>1998</lpage>. <comment>https://doi.org/10.1016/j.matt.2020.09.027</comment> <pub-id pub-id-type="doi">10.1016/j.matt.2020.09.027</pub-id></mixed-citation></ref>
<ref id="ref44"><label>44.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Siew</surname> <given-names>Q.Y.</given-names></name><name><surname>Pang</surname> <given-names>E.L.</given-names></name><name><surname>Loh</surname> <given-names>H.S.</given-names></name><name><surname>Tan</surname> <given-names>M.T.</given-names></name></person-group>. <article-title>Highly sensitive and specific graphene/TiO2 impedimetric immunosensor based on plant-derived tetravalent envelope glycoprotein domain III (EDIII) probe antigen for dengue diagnosis</article-title>. <source>Biosensors and Bioelectronics</source> <volume>176</volume> (<year>2021</year>) <fpage>112895</fpage>. <comment>https://doi.org/10.1016/j.bios.2020.112895</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2020.112895</pub-id></mixed-citation></ref>
<ref id="ref45"><label>45.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname> <given-names>Y.</given-names></name><name><surname>Choi</surname> <given-names>J.</given-names></name><name><surname>Han</surname> <given-names>H.K.</given-names></name><name><surname>Park</surname> <given-names>S.</given-names></name><name><surname>Park</surname> <given-names>S.Y.</given-names></name><name><surname>Park</surname> <given-names>C.</given-names></name><name><surname>Baek</surname> <given-names>C.</given-names></name><name><surname>Lee</surname> <given-names>T.</given-names></name><name><surname>Min</surname> <given-names>J.</given-names></name></person-group>. <article-title>Fabrication of ultrasensitive electrochemical biosensor for dengue fever viral RNA Based on CRISPR/Cpf1 reaction</article-title>. <source>Sensors and Actuators B</source> <volume>326</volume> (<year>2021</year>) <fpage>128677</fpage>. <comment>https://doi.org/10.1016/j.snb.2020.128677</comment> <pub-id pub-id-type="doi">10.1016/j.snb.2020.128677</pub-id></mixed-citation></ref>
<ref id="ref46"><label>46.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname> <given-names>X.</given-names></name><name><surname>Kang</surname> <given-names>S.</given-names></name><name><surname>Ikbal</surname> <given-names>M.A.</given-names></name><name><surname>Zhao</surname> <given-names>Z.</given-names></name><name><surname>Pan</surname> <given-names>Y.</given-names></name><name><surname>Zuo</surname> <given-names>J.</given-names></name><name><surname>Gu</surname> <given-names>L.</given-names></name><name><surname>Wang</surname> <given-names>C.</given-names></name></person-group>. <article-title>Synthetic nanobody-functionalized nanoparticles for accelerated development of rapid, accessible detection of viral antigens</article-title>. <source>Biosensors and Bioelectronics</source> <volume>202</volume> (<year>2022</year>) <fpage>113971</fpage>. <comment>https://doi.org/10.1016/j.bios.2022.113971</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2022.113971</pub-id></mixed-citation></ref>
<ref id="ref47"><label>47.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yadav</surname> <given-names>S.</given-names></name><name><surname>Sadique</surname> <given-names>M.A.</given-names></name><name><surname>Ranjan</surname> <given-names>P.</given-names></name><name><surname>Khan</surname> <given-names>R.</given-names></name><name><surname>Sathish</surname> <given-names>N.</given-names></name><name><surname>Srivastava</surname> <given-names>A.K.</given-names></name></person-group>. <article-title>Polydopamine decorated MoS 2 nanosheet based electrochemical immunosensor for sensitive detection of SARS-CoV-2 nucleocapsid protein in clinical samples</article-title>. <source>Journal of Materials Chemistry B</source> <volume>10</volume> (<year>2022</year>) <fpage>8478</fpage>-<lpage>8489</lpage>. <comment>https://doi.org/10.1039/D2TB01409B</comment> <pub-id pub-id-type="doi">10.1039/D2TB01409B</pub-id></mixed-citation></ref>
<ref id="ref48"><label>48.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sangili</surname> <given-names>A.</given-names></name><name><surname>Kalyani</surname> <given-names>T.</given-names></name><name><surname>Chen</surname> <given-names>S.M.</given-names></name><name><surname>Rajendran</surname> <given-names>K.</given-names></name><name><surname>Jana</surname> <given-names>S.K.</given-names></name></person-group>. <article-title>Label-free electrochemical immunosensor based on l-cysteine-functionalized AuNP on reduced graphene oxide for the detection of dengue virus E-protein in dengue blood serum</article-title>. <source>Composites B</source> <volume>238</volume> (<year>2022</year>) <fpage>109876</fpage>. <comment>https://doi.org/10.1016/j.compositesb.2022.109876</comment> <pub-id pub-id-type="doi">10.1016/j.compositesb.2022.109876</pub-id></mixed-citation></ref>
<ref id="ref49"><label>49.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Del Ca&#x00F1;o</surname> <given-names>R.</given-names></name><name><surname>Garc&#x00ED;a-Mendiola</surname> <given-names>T.</given-names></name><name><surname>Garc&#x00ED;a-Nieto</surname> <given-names>D.</given-names></name><name><surname>&#x00C1;lvaro</surname> <given-names>R.</given-names></name><name><surname>Luna</surname> <given-names>M.</given-names></name><name><surname>Iniesta</surname> <given-names>H.A.</given-names></name><name><surname>Coloma</surname> <given-names>R.</given-names></name><name><surname>Diaz</surname> <given-names>C.R.</given-names></name><name><surname>Mil&#x00E1;n-Rois</surname> <given-names>P.</given-names></name><name><surname>Castellanos</surname> <given-names>M.</given-names></name><name><surname>Abreu</surname> <given-names>M.</given-names></name></person-group>. <article-title>Amplification-free detection of SARS-CoV-2 using gold nanotriangles functionalized with oligonucleotides</article-title>. <source>Microchimica Acta</source> <volume>189</volume> (<year>2022</year>) <fpage>171</fpage>. <comment>https://doi.org/10.1007/s00604-022-05272-y</comment> <pub-id pub-id-type="doi">10.1007/s00604-022-05272-y</pub-id></mixed-citation></ref>
<ref id="ref50"><label>50.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Braz</surname> <given-names>B.A.</given-names></name><name><surname>Hospinal-Santiani</surname> <given-names>M.</given-names></name><name><surname>Martins</surname> <given-names>G.</given-names></name><name><surname>Gogola</surname> <given-names>J.L.</given-names></name><name><surname>Valenga</surname> <given-names>M.G.</given-names></name><name><surname>Beir&#x00E3;o</surname> <given-names>B.C.</given-names></name><name><surname>Bergamini</surname> <given-names>M.F.</given-names></name><name><surname>Marcolino-Junior</surname> <given-names>L.H.</given-names></name><name><surname>Thomaz-Soccol</surname> <given-names>V.</given-names></name><name><surname>Soccol</surname> <given-names>C.R.</given-names></name></person-group>. <article-title>Gold-binding peptide as a selective layer for electrochemical detection of SARS-CoV-2 antibodies</article-title>. <source>Talanta</source> <volume>257</volume> (<year>2023</year>) <fpage>124348</fpage>. <comment>https://doi.org/10.1016/j.talanta.2023.124348</comment> <pub-id pub-id-type="doi">10.1016/j.talanta.2023.124348</pub-id></mixed-citation></ref>
<ref id="ref51"><label>51.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Freko</surname> <given-names>S.</given-names></name><name><surname>Niki&#x0107;</surname><given-names>M.</given-names></name><name><surname>Mayer</surname> <given-names>D.</given-names></name><name><surname>Wei&#x00DF;</surname> <given-names>L.I.</given-names></name><name><surname>Simmel</surname> <given-names>F.C.</given-names></name><name><surname>Wolfrum</surname> <given-names>B.</given-names></name></person-group>. <article-title>Digital CRISPR-Powered Biosensor Concept without Target Amplification Using Single-Impact Electrochemistry</article-title>. <source>ACS Sensors</source> <volume>9</volume> (<year>2024</year>) <fpage>6197</fpage>-<lpage>206</lpage>. <comment>https://doi/10.1021/acssensors.4c02060</comment> <pub-id pub-id-type="doi">10.1021/acssensors.4c02060</pub-id></mixed-citation></ref>
<ref id="ref52"><label>52.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kaur</surname> <given-names>H.</given-names></name><name><surname>Shorie</surname> <given-names>M.</given-names></name><name><surname>Sharma</surname> <given-names>M.</given-names></name><name><surname>Ganguli</surname> <given-names>A.K.</given-names></name><name><surname>Sabherwal</surname> <given-names>P.</given-names></name></person-group>. <article-title>Bridged Rebar Graphene functionalized aptasensor for pathogenic E. coli O78: K80: H11 detection</article-title>. <source>Biosensors and Bioelectronics</source> <volume>98</volume> (<year>2017</year>) <fpage>486</fpage>-<lpage>493</lpage>. <comment>https://doi.org/10.1016/j.bios.2017.07.004</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2017.07.004</pub-id></mixed-citation></ref>
<ref id="ref53"><label>53.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname> <given-names>X.</given-names></name><name><surname>Xie</surname> <given-names>G.</given-names></name><name><surname>Gou</surname> <given-names>D.</given-names></name><name><surname>Luo</surname> <given-names>P.</given-names></name><name><surname>Yao</surname> <given-names>Y.</given-names></name><name><surname>Chen</surname> <given-names>H.</given-names></name></person-group>. <article-title>A novel enzyme-free electrochemical biosensor for rapid detection of Pseudomonas aeruginosa based on high catalytic Cu-ZrMOF and conductive Super P</article-title>. <source>Biosensors and Bioelectronics</source> <volume>142</volume> (<year>2019</year>) <fpage>111486</fpage>. <comment>https://doi.org/10.1016/j.bios.2019.111486</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2019.111486</pub-id></mixed-citation></ref>
<ref id="ref54"><label>54.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cui</surname> <given-names>L.</given-names></name><name><surname>Chang</surname> <given-names>W.</given-names></name><name><surname>Wei</surname> <given-names>R.</given-names></name><name><surname>Chen</surname> <given-names>W.</given-names></name><name><surname>Tang</surname> <given-names>Y.</given-names></name><name><surname>Yue</surname> <given-names>X.</given-names></name></person-group>. <article-title>Aptamer and Ru (bpy) 32&#x002B;-AuNPs-based electrochemiluminescence biosensor for accurate detecting Listeria monocytogenes</article-title>. <source>Journal of Food Safety</source> <volume>42</volume> (<year>2022</year>) <fpage>e13008</fpage>. <comment>https://doi.org/10.1111/jfs.13008</comment> <pub-id pub-id-type="doi">10.1111/jfs.13008</pub-id></mixed-citation></ref>
<ref id="ref55"><label>55.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sohouli</surname> <given-names>E.</given-names></name><name><surname>Ghalkhani</surname> <given-names>M.</given-names></name><name><surname>Zargar</surname> <given-names>T.</given-names></name><name><surname>Joseph</surname> <given-names>Y.</given-names></name><name><surname>Rahimi-Nasrabadi</surname> <given-names>M.</given-names></name><name><surname>Ahmadi</surname> <given-names>F.</given-names></name><name><surname>Plonska-Brzezinska</surname> <given-names>M.E.</given-names></name><name><surname>Ehrlich</surname> <given-names>H.</given-names></name></person-group>. <article-title>A new electrochemical aptasensor based on gold/nitrogen-doped carbon nano-onions for the detection of Staphylococcus aureus</article-title>. <source>Electrochimica Acta</source> <volume>403</volume> (<year>2022</year>) <fpage>139633</fpage>. <comment>https://doi.org/10.1016/j.electacta.2021.139633</comment> <pub-id pub-id-type="doi">10.1016/j.electacta.2021.139633</pub-id></mixed-citation></ref>
<ref id="ref56"><label>56.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Abedi</surname> <given-names>R.</given-names></name><name><surname>Raoof</surname> <given-names>J.B.</given-names></name><name><surname>Mohseni</surname> <given-names>M.</given-names></name><name><surname>Hashkavayi</surname> <given-names>A.B.</given-names></name></person-group>. <article-title>Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria</article-title>. <source>Analytical Biochemistry</source> <volume>679</volume> (<year>2023</year>) <fpage>115288</fpage>. <comment>https://doi.org/10.1016/j.ab.2023.115288</comment> <pub-id pub-id-type="doi">10.1016/j.ab.2023.115288</pub-id></mixed-citation></ref>
<ref id="ref57"><label>57.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhong</surname> <given-names>X.</given-names></name><name><surname>Deng</surname> <given-names>Y.</given-names></name><name><surname>Yang</surname> <given-names>Q.</given-names></name><name><surname>Yi</surname> <given-names>S.</given-names></name><name><surname>Qiu</surname> <given-names>H.</given-names></name><name><surname>Chen</surname> <given-names>L.</given-names></name><name><surname>Hu</surname> <given-names>S.</given-names></name></person-group>. <article-title>An extracellular electron transfer enhanced electrochemiluminescence aptasensor for Escherichia coli analysis</article-title>. <source>Analyst</source> <volume>148</volume> (<year>2023</year>) <fpage>4414</fpage>-<lpage>4420</lpage>. <comment>https://doi.org/10.1039/D3AN01038D</comment> <pub-id pub-id-type="doi">10.1039/D3AN01038D</pub-id></mixed-citation></ref>
<ref id="ref58"><label>58.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yadav</surname> <given-names>A.K.</given-names></name><name><surname>Verma</surname> <given-names>D.</given-names></name><name><surname>Tabassum</surname> <given-names>S.</given-names></name><name><surname>Solanki</surname> <given-names>P.R.</given-names></name></person-group>. <article-title>Functionalized graphitic carbon nitride based aptasensing platform for electrochemical detection of Helicobacter pylori</article-title>. <source>IEEE Sensors Letters</source> <volume>7</volume> (<year>2023</year>) <fpage>4503604</fpage>. <comment>https://doi.org/10.1109/LSENS.2023.3327589</comment> <pub-id pub-id-type="doi">10.1109/LSENS.2023.3327589</pub-id></mixed-citation></ref>
<ref id="ref59"><label>59.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jaradat</surname> <given-names>H.</given-names></name><name><surname>Al-Hamry</surname> <given-names>A.</given-names></name><name><surname>Ibbini</surname> <given-names>M.</given-names></name><name><surname>Fourati</surname> <given-names>N.</given-names></name><name><surname>Kanoun</surname> <given-names>O.</given-names></name></person-group>. <article-title>Novel sensitive electrochemical immunosensor development for the selective detection of HopQ H. pylori bacteria biomarker</article-title>. <source>Biosensors</source> <volume>13</volume> (<year>2023</year>) <fpage>527</fpage>. <comment>https://doi.org/10.3390/bios13050527</comment> <pub-id pub-id-type="doi">10.3390/bios13050527</pub-id></mixed-citation></ref>
<ref id="ref60"><label>60.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname> <given-names>P.</given-names></name><name><surname>Yu</surname> <given-names>G.</given-names></name><name><surname>Wei</surname> <given-names>J.</given-names></name><name><surname>Liao</surname> <given-names>X.</given-names></name><name><surname>Zhang</surname> <given-names>Y.</given-names></name><name><surname>Ren</surname> <given-names>Y.</given-names></name><name><surname>Zhang</surname> <given-names>C.</given-names></name><name><surname>Wang</surname> <given-names>Y.</given-names></name><name><surname>Zhang</surname> <given-names>D.</given-names></name><name><surname>Wang</surname> <given-names>J.</given-names></name><name><surname>Wang</surname> <given-names>Y.</given-names></name></person-group>. <article-title>A single thiolated-phage displayed nanobody-based biosensor for label-free detection of foodborne pathogen</article-title>. <source>Journal of Hazardous Materials</source> <volume>443</volume> (<year>2023</year>) <fpage>130157</fpage>. <comment>https://doi.org/10.1016/j.jhazmat.2022.130157</comment> <pub-id pub-id-type="doi">10.1016/j.jhazmat.2022.130157</pub-id></mixed-citation></ref>
<ref id="ref61"><label>61.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Braz</surname> <given-names>B.A.</given-names></name><name><surname>Hospinal-Santiani</surname> <given-names>M.</given-names></name><name><surname>Martins</surname> <given-names>G.</given-names></name><name><surname>Beir&#x00E3;o</surname> <given-names>B.C.</given-names></name><name><surname>Bergamini</surname> <given-names>M.F.</given-names></name><name><surname>Marcolino-Junior</surname> <given-names>L.H.</given-names></name><name><surname>Soccol</surname> <given-names>C.R.</given-names></name><name><surname>Thomaz-Soccol</surname><given-names>V.</given-names></name></person-group>. <article-title>Disposable electrochemical platform based on solid-binding peptides and carbon nanomaterials: An alternative device for leishmaniasis detection</article-title>. <source>Microchimica Acta</source> <volume>190</volume> (<year>2023</year>) <fpage>321</fpage>. <comment>https://doi.org/10.1007/s00604-023-05891-z</comment> <pub-id pub-id-type="doi">10.1007/s00604-023-05891-z</pub-id></mixed-citation></ref>
<ref id="ref62"><label>62.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hu</surname> <given-names>S.</given-names></name><name><surname>Zhong</surname> <given-names>X.</given-names></name><name><surname>Deng</surname> <given-names>Y.</given-names></name><name><surname>Deng</surname> <given-names>Y.</given-names></name><name><surname>Chen</surname> <given-names>L.</given-names></name></person-group>. <article-title>An initial check-reexamination strategy for analysis of H. Pylori DNA and single-nucleotide variants</article-title>. <source>Sensors and Actuators B</source> <volume>398</volume> (<year>2024</year>) <fpage>134746</fpage>. <comment>https://doi.org/10.1016/j.snb.2023.134746</comment> <pub-id pub-id-type="doi">10.1016/j.snb.2023.134746</pub-id></mixed-citation></ref>
<ref id="ref63"><label>63.</label> <mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Anik</surname> <given-names>U.</given-names></name></person-group>, <source>Electrochemical medical biosensors for POC applications</source>, <publisher-name>Woodhead Publishing</publisher-name>, <publisher-loc>New Delhi, India</publisher-loc>, <year>2017</year>, p. <fpage>17</fpage>. <comment>https://doi.org/10.1016/B978-0-08-100072-4.00012-5</comment> <pub-id pub-id-type="doi">10.1016/B978-0-08-100072-4.00012-5</pub-id></mixed-citation></ref>
<ref id="ref64"><label>64.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jain</surname> <given-names>S.</given-names></name><name><surname>Nehra</surname> <given-names>M.</given-names></name><name><surname>Kumar</surname> <given-names>R.</given-names></name><name><surname>Dilbaghi</surname> <given-names>N.</given-names></name><name><surname>Hu</surname> <given-names>T.</given-names></name><name><surname>Kumar</surname> <given-names>S.</given-names></name><name><surname>Kaushik</surname> <given-names>A.</given-names></name><name><surname>Li</surname> <given-names>C.Z.</given-names></name></person-group>. <article-title>Internet of medical things (IoMT)-integrated biosensors for point-of-care testing of infectious diseases</article-title>. <source>Biosensors and Bioelectronics</source> <volume>179</volume> (<year>2021</year>) <fpage>113074</fpage>. <comment>https://doi.org/10.1016/j.bios.2021.113074</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2021.113074</pub-id></mixed-citation></ref>
<ref id="ref65"><label>65.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gowri</surname> <given-names>A.</given-names></name><name><surname>Kumar</surname> <given-names>N.A.</given-names></name><name><surname>Anand</surname> <given-names>B.S.</given-names></name></person-group>. <article-title>Recent advances in nanomaterials-based biosensors for point of care (PoC) diagnosis of COVID-19&#x2013;a minireview</article-title>. <source>TrAC Trends in Analytical Chemistry</source> <volume>137</volume> (<year>2021</year>) <fpage>116205</fpage>. <comment>https://doi.org/10.1016/j.trac.2021.116205</comment> <pub-id pub-id-type="doi">10.1016/j.trac.2021.116205</pub-id></mixed-citation></ref>
<ref id="ref66"><label>66.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chaudhary</surname> <given-names>V.</given-names></name><name><surname>Khanna</surname> <given-names>V.</given-names></name><name><surname>Awan</surname> <given-names>H.T.</given-names></name><name><surname>Singh</surname> <given-names>K.</given-names></name><name><surname>Khalid</surname> <given-names>M.</given-names></name><name><surname>Mishra</surname> <given-names>Y.K.</given-names></name><name><surname>Bhansali</surname> <given-names>S.</given-names></name><name><surname>Li</surname> <given-names>C.Z.</given-names></name><name><surname>Kaushik</surname> <given-names>A.</given-names></name></person-group>. <article-title>Towards hospital-on-chip supported by 2D MXenes-based 5th generation intelligent biosensors</article-title>. <source>Biosensors and Bioelectronics</source> <volume>220</volume> (<year>2023</year>) <fpage>114847</fpage>. <comment>https://doi.org/10.1016/j.bios.2022.114847</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2022.114847</pub-id></mixed-citation></ref>
<ref id="ref67"><label>67.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nur</surname> <given-names>Y.</given-names></name><name><surname>Zein</surname> <given-names>M.I.</given-names></name><name><surname>Irkham</surname> <given-names>I.</given-names></name><name><surname>Gaffar</surname> <given-names>S.</given-names></name><name><surname>Subroto</surname> <given-names>T.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>Cerium oxide nanoparticles-assisted aptasensor for chronic myeloid leukaemia detection</article-title>. <source>ADMET and DMPK</source> <volume>12</volume> (<year>2024</year>) <fpage>623</fpage>-<lpage>35</lpage>. <comment>https://doi.org/10.5599/admet.2404</comment> <pub-id pub-id-type="doi">10.5599/admet.2404</pub-id></mixed-citation></ref>
<ref id="ref68"><label>68.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zein</surname> <given-names>M.I.</given-names></name><name><surname>Kharismasari</surname> <given-names>C.Y.</given-names></name><name><surname>Hardianto</surname> <given-names>A.</given-names></name><name><surname>Zakiyyah</surname> <given-names>S.N.</given-names></name><name><surname>Amalia</surname> <given-names>R.</given-names></name><name><surname>Ozsoz</surname> <given-names>M.</given-names></name><name><surname>Mirasoli</surname> <given-names>M.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>A CRISPR/Cas12a electrochemical biosensing to detect pig mtDNA D-loop for ensuring food authenticity</article-title>. <source>Sensing and Bio-Sensing Research</source> <volume>1</volume> (<year>2025</year>) <fpage>100755</fpage>. <comment>https://doi.org/10.1016/j.sbsr.2025.100755</comment> <pub-id pub-id-type="doi">10.1016/j.sbsr.2025.100755</pub-id></mixed-citation></ref>
<ref id="ref69"><label>69.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Akg&#x00F6;n&#x00FC;ll&#x00FC;</surname> <given-names>S.</given-names></name><name><surname>Denizli</surname> <given-names>A.</given-names></name></person-group>. <article-title>Recent advances in optical biosensing approaches for biomarkers detection</article-title>. <source>Biosensors and Bioelectronics: X</source>. <volume>12</volume> (<year>2022</year>) <fpage>100269</fpage>. <comment>https://doi.org/10.1016/j.biosx.2022.100269</comment> <pub-id pub-id-type="doi">10.1016/j.biosx.2022.100269</pub-id></mixed-citation></ref>
<ref id="ref70"><label>70.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pour</surname> <given-names>S.R.</given-names></name><name><surname>Calabria</surname> <given-names>D.</given-names></name><name><surname>Emamiamin</surname> <given-names>A.</given-names></name><name><surname>Lazzarini</surname> <given-names>E.</given-names></name><name><surname>Pace</surname> <given-names>A.</given-names></name><name><surname>Guardigli</surname> <given-names>M.</given-names></name><name><surname>Zangheri</surname> <given-names>M.</given-names></name><name><surname>Mirasoli</surname> <given-names>M.</given-names></name></person-group>. <article-title>Electrochemical vs. optical biosensors for point-of-care applications: A critical Review</article-title>. <source>Chemosensors</source> <volume>11</volume> (<year>2023</year>) <fpage>546</fpage>. <comment>https://doi.org/10.3390/chemosensors11100546</comment> <pub-id pub-id-type="doi">10.3390/chemosensors11100546</pub-id></mixed-citation></ref>
<ref id="ref71"><label>71.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mostufa</surname> <given-names>S.</given-names></name><name><surname>Rezaei</surname> <given-names>B.</given-names></name><name><surname>Ciannella</surname> <given-names>S.</given-names></name><name><surname>Yari</surname> <given-names>P.</given-names></name><name><surname>G&#x00F3;mez-Pastora</surname> <given-names>J.</given-names></name><name><surname>He</surname> <given-names>R.</given-names></name><name><surname>Wu</surname> <given-names>K.</given-names></name></person-group>. <article-title>Advancements and perspectives in optical biosensors</article-title>. <source>ACS Omega</source> <volume>9</volume> (<year>2024</year>) <fpage>24181</fpage>-<lpage>24202</lpage>. <comment>https://doi/full/10.1021/acsomega.4c01872</comment> <pub-id pub-id-type="doi">10.1021/acsomega.4c01872</pub-id></mixed-citation></ref>
<ref id="ref72"><label>72.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sang</surname> <given-names>S.</given-names></name><name><surname>Wang</surname> <given-names>Y.</given-names></name><name><surname>Feng</surname> <given-names>Q.</given-names></name><name><surname>Wei</surname> <given-names>Y.</given-names></name><name><surname>Ji</surname> <given-names>J.</given-names></name><name><surname>Zhang</surname> <given-names>W.</given-names></name></person-group>. <article-title>Progress of new label-free techniques for biosensors: A review</article-title>. <source>Critical Reviews in Biotechnology</source> <volume>36</volume> (<year>2016</year>) <fpage>465</fpage>-<lpage>481</lpage>. <comment>https://doi.org/10.3109/07388551.2014.991270</comment> <pub-id pub-id-type="doi">10.3109/07388551.2014.991270</pub-id></mixed-citation></ref>
<ref id="ref73"><label>73.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khansili</surname> <given-names>N.</given-names></name><name><surname>Rattu</surname> <given-names>G.</given-names></name><name><surname>Krishna</surname> <given-names>P.M.</given-names></name><name name-style="given-only"><given-names>P.M.</given-names></name></person-group> <article-title>Label-free optical biosensors for food and biological sensor applications</article-title>. <source>Sensors and Actuators B</source> <volume>265</volume> (<year>2018</year>) <fpage>35</fpage>-<lpage>49</lpage>. <comment>https://doi.org/10.1016/j.snb.2018.03.004</comment> <pub-id pub-id-type="doi">10.1016/j.snb.2018.03.004</pub-id></mixed-citation></ref>
<ref id="ref74"><label>74.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ramirez</surname> <given-names>J.C.</given-names></name><name><surname>Grajales Garc&#x00ED;a</surname> <given-names>D.</given-names></name><name><surname>Maldonado</surname> <given-names>J.</given-names></name><name><surname>Fern&#x00E1;ndez-Gavela</surname><given-names>A.</given-names></name></person-group>. <article-title>Current trends in photonic biosensors: advances towards multiplexed integration</article-title>. <source>Chemosensors</source> <volume>10</volume> (<year>2022</year>) <fpage>398</fpage>. <comment>https://doi.org/10.3390/chemosensors10100398</comment> <pub-id pub-id-type="doi">10.3390/chemosensors10100398</pub-id></mixed-citation></ref>
<ref id="ref75"><label>75.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pakchin</surname> <given-names>P.S.</given-names></name><name><surname>Fathi</surname> <given-names>F.</given-names></name><name><surname>Samadi</surname> <given-names>H.</given-names></name><name><surname>Adibkia</surname> <given-names>K.</given-names></name></person-group>. <article-title>Recent Advances in Receptor-Based Optical Biosensors for the Detection of Multiplex Biomarkers</article-title>. <source>Talanta</source> <volume>281</volume> (<year>2024</year>) <fpage>126852</fpage>. <comment>https://doi.org/10.1016/j.talanta.2024.126852</comment> <pub-id pub-id-type="doi">10.1016/j.talanta.2024.126852</pub-id></mixed-citation></ref>
<ref id="ref76"><label>76.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kim</surname> <given-names>H.E.</given-names></name><name><surname>Schuck</surname> <given-names>A.</given-names></name><name><surname>Lee</surname> <given-names>S.H.</given-names></name><name><surname>Lee</surname> <given-names>Y.</given-names></name><name><surname>Kang</surname> <given-names>M.</given-names></name><name><surname>Kim</surname> <given-names>Y.S.</given-names></name></person-group>. <article-title>Sensitive electrochemical biosensor combined with isothermal amplification for point-of-care COVID-19 tests</article-title>. <source>Biosensors and Bioelectronics</source> <volume>182</volume> (<year>2021</year>) <fpage>113168</fpage>. <comment>https://doi.org/10.1016/j.bios.2021.113168</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2021.113168</pub-id></mixed-citation></ref>
<ref id="ref77"><label>77.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Seo</surname> <given-names>G.</given-names></name><name><surname>Lee</surname> <given-names>G.</given-names></name><name><surname>Kim</surname> <given-names>M.J.</given-names></name><name><surname>Baek</surname> <given-names>S.H.</given-names></name><name><surname>Choi</surname> <given-names>M.</given-names></name><name><surname>Ku</surname> <given-names>K.B.</given-names></name><name><surname>Lee</surname> <given-names>C.S.</given-names></name><name><surname>Jun</surname> <given-names>S.</given-names></name><name><surname>Park</surname> <given-names>D.</given-names></name><name><surname>Kim</surname> <given-names>H.G.</given-names></name><name><surname>Kim</surname> <given-names>S.J.</given-names></name></person-group>. <article-title>Rapid detection of COVID-19 causative virus (SARS-CoV-2) in human nasopharyngeal swab specimens using field-effect transistor-based biosensor</article-title>. <source>ACS nano</source> <volume>14</volume> (<year>2020</year>) <fpage>5135</fpage>-<lpage>5142</lpage>. <comment>https://doi.org/10.1021/acsnano.0c02823</comment> <pub-id pub-id-type="doi">10.1021/acsnano.0c02823</pub-id></mixed-citation></ref>
<ref id="ref78"><label>78.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yakoh</surname> <given-names>A.</given-names></name><name><surname>Pimpitak</surname> <given-names>U.</given-names></name><name><surname>Rengpipat</surname> <given-names>S.</given-names></name><name><surname>Hirankarn</surname> <given-names>N.</given-names></name><name><surname>Chailapakul</surname> <given-names>O.</given-names></name><name><surname>Chaiyo</surname> <given-names>S.</given-names></name></person-group>. <article-title>Paper-based electrochemical biosensor for diagnosing COVID-19: Detection of SARS-CoV-2 antibodies and antigen</article-title>. <source>Biosensors and Bioelectronics</source> <volume>176</volume> (<year>2021</year>) <fpage>112912</fpage>. <comment>https://doi.org/10.1016/j.bios.2020.112912</comment> <pub-id pub-id-type="doi">10.1016/j.bios.2020.112912</pub-id></mixed-citation></ref>
<ref id="ref79"><label>79.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Parmin</surname> <given-names>N.A.</given-names></name><name><surname>Hashim</surname> <given-names>U.</given-names></name><name><surname>Gopinath</surname> <given-names>S.C.</given-names></name><name><surname>Dahalan</surname> <given-names>F.A.</given-names></name><name><surname>Voon</surname> <given-names>C.H.</given-names></name><name><surname>Uda</surname> <given-names>M.N.</given-names></name><name><surname>Uda</surname> <given-names>M.A.</given-names></name><name><surname>Rejali</surname> <given-names>Z.</given-names></name><name><surname>Afzan</surname> <given-names>A.</given-names></name><name><surname>Jaapar</surname> <given-names>F.N.</given-names></name><name><surname>Halim</surname> <given-names>F.S.</given-names></name></person-group>. <article-title>A mini review of electrochemical genosensor based biosensor diagnostic system for infectious diseases</article-title>. <source>Environmental and Toxicology Management</source> <volume>1</volume> (<year>2021</year>) <fpage>14</fpage>-<lpage>17</lpage>. <comment>https://doi.org/10.33086/etm.v1i1.2038</comment> <pub-id pub-id-type="doi">10.33086/etm.v1i1.2038</pub-id></mixed-citation></ref>
<ref id="ref80"><label>80.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Babaei</surname> <given-names>A.</given-names></name><name><surname>Pouremamali</surname> <given-names>A.</given-names></name><name><surname>Rafiee</surname> <given-names>N.</given-names></name><name><surname>Sohrabi</surname> <given-names>H.</given-names></name><name><surname>Mokhtarzadeh</surname> <given-names>A.</given-names></name><name><surname>de la Guardia</surname><given-names>M.</given-names></name></person-group>. <article-title>Genosensors as an alternative diagnostic sensing approaches for specific detection of virus species: a review of common techniques and outcomes</article-title>. <source>TrAC Trends in Analytical Chemistry</source> <volume>155</volume> (<year>2022</year>) <fpage>116686</fpage>. <comment>https://doi.org/10.1016/j.trac.2022.116686</comment> <pub-id pub-id-type="doi">10.1016/j.trac.2022.116686</pub-id></mixed-citation></ref>
<ref id="ref81"><label>81.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bagheri</surname> <given-names>H.A.</given-names></name><name><surname>Raoof</surname> <given-names>J.B.</given-names></name><name><surname>Azimi</surname> <given-names>R.</given-names></name><name><surname>Ojani</surname> <given-names>R.</given-names></name></person-group>. <article-title>Label-free and sensitive aptasensor based on dendritic gold nanostructures on functionalized SBA-15 for determination of chloramphenicol</article-title>. <source>Analytical and Bioanalytical Chemistry</source> <volume>408</volume> (<year>2016</year>) <fpage>2557</fpage>-<lpage>2565</lpage>. <comment>https://doi.org/10.1007/S00216-016-9358-6</comment> <pub-id pub-id-type="doi">10.1007/S00216-016-9358-6</pub-id></mixed-citation></ref>
<ref id="ref82"><label>82.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lim</surname> <given-names>W.Q.</given-names></name><name><surname>Gao</surname> <given-names>Z.</given-names></name></person-group>. <article-title>Metal oxide nanoparticles in electroanalysis</article-title>. <source>Electroanalysis</source> <volume>27</volume> (<year>2015</year>) <fpage>2074</fpage>-<lpage>2090</lpage>. <comment>https://doi.org/10.1002/elan.201500024</comment> <pub-id pub-id-type="doi">10.1002/elan.201500024</pub-id></mixed-citation></ref>
<ref id="ref83"><label>83.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>He</surname> <given-names>Y.</given-names></name><name><surname>Ren</surname> <given-names>Y.</given-names></name><name><surname>Guo</surname> <given-names>B.</given-names></name><name><surname>Yang</surname> <given-names>Y.</given-names></name><name><surname>Ji</surname> <given-names>Y.</given-names></name><name><surname>Zhang</surname> <given-names>D.</given-names></name><name><surname>Wang</surname> <given-names>J.</given-names></name><name><surname>Wang</surname> <given-names>Y.</given-names></name><name><surname>Wang</surname> <given-names>H.</given-names></name></person-group>. <article-title>Development of a specific nanobody and its application in rapid and selective determination of Salmonella enteritidis in milk</article-title>. <source>Food Chemistry</source> <volume>310</volume> (<year>2020</year>) <fpage>125942</fpage>. <comment>https://doi.org/10.1016/j.foodchem.2019.125942</comment> <pub-id pub-id-type="doi">10.1016/j.foodchem.2019.125942</pub-id></mixed-citation></ref>
<ref id="ref84"><label>84.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>He</surname> <given-names>Y.</given-names></name><name><surname>Tian</surname> <given-names>F.</given-names></name><name><surname>Zhou</surname> <given-names>J.</given-names></name><name><surname>Zhao</surname> <given-names>Q.</given-names></name><name><surname>Fu</surname> <given-names>R.</given-names></name><name><surname>Jiao</surname> <given-names>B.</given-names></name></person-group>. <article-title>Colorimetric aptasensor for ochratoxin A detection based on enzyme-induced gold nanoparticle aggregation</article-title>. <source>Journal of Hazardous Materials</source> <volume>388</volume> (<year>2020</year>) <fpage>121758</fpage>. <comment>https://doi.org/10.1016/j.jhazmat.2019.121758</comment> <pub-id pub-id-type="doi">10.1016/j.jhazmat.2019.121758</pub-id></mixed-citation></ref>
<ref id="ref85"><label>85.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Land</surname> <given-names>K.J.</given-names></name><name><surname>Boeras</surname> <given-names>D.I.</given-names></name><name><surname>Chen</surname> <given-names>X.S.</given-names></name><name><surname>Ramsay</surname> <given-names>A.R.</given-names></name><name><surname>Peeling</surname> <given-names>R.W.</given-names></name></person-group>. <article-title>REASSURED diagnostics to inform disease control strategies, strengthen health systems and improve patient outcomes</article-title>. <source>Nature microbiology</source> <volume>4</volume> (<year>2019</year>) <fpage>46</fpage>-<lpage>54</lpage>. <comment>https://doi.org/10.1038/s41564-018-0295-3</comment> <pub-id pub-id-type="doi">10.1038/s41564-018-0295-3</pub-id></mixed-citation></ref>
<ref id="ref86"><label>86.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Haghayegh</surname> <given-names>F.</given-names></name><name><surname>Norouziazad</surname> <given-names>A.</given-names></name><name><surname>Haghani</surname> <given-names>E.</given-names></name><name><surname>Feygin</surname> <given-names>A.A.</given-names></name><name><surname>Rahimi</surname> <given-names>R.H.</given-names></name><name><surname>Ghavamabadi</surname> <given-names>H.A.</given-names></name><name><surname>Sadighbayan</surname> <given-names>D.</given-names></name><name><surname>Madhoun</surname> <given-names>F.</given-names></name><name><surname>Papagelis</surname> <given-names>M.</given-names></name><name><surname>Felfeli</surname> <given-names>T.</given-names></name><name><surname>Salahandish</surname> <given-names>R.</given-names></name></person-group>. <article-title>Revolutionary Point-of-Care Wearable Diagnostics for Early Disease Detection and Biomarker Discovery through Intelligent Technologies</article-title>. <source>Advanced Science</source> <volume>11</volume> (<year>2024</year>) <fpage>2400595</fpage>. <comment>https://doi.org/10.1002/advs.202400595</comment> <pub-id pub-id-type="doi">10.1002/advs.202400595</pub-id></mixed-citation></ref>
<ref id="ref87"><label>87.</label> <mixed-citation publication-type="book"><person-group person-group-type="author"><name><surname>Kaur</surname> <given-names>R.</given-names></name><name name-style="given-only"><given-names>S.K.</given-names></name></person-group>. <article-title>Sharma, Tripathy. Advantages and limitations of environmental nanosensors</article-title>, in <source>Advances in nanosensors for biological and environmental analysis</source>, <person-group person-group-type="editor"><name><surname>Deep</surname><given-names>A.</given-names></name><name><surname>Kumar</surname><given-names>S.</given-names></name></person-group>, Eds., <publisher-name>Elsevier</publisher-name>, <publisher-loc>Amsterdam, Netherlands</publisher-loc>, <year>2019</year> p. <lpage>13</lpage>. <comment>https://doi.org/10.1016/B978-0-12-817456-2.00007-3</comment> <pub-id pub-id-type="doi">10.1016/B978-0-12-817456-2.00007-3</pub-id></mixed-citation></ref>
<ref id="ref88"><label>88.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sreejith</surname> <given-names>S.</given-names></name><name><surname>Ajayan</surname> <given-names>J.</given-names></name><name><surname>Radhika</surname> <given-names>J.M.</given-names></name><name><surname>Reddy</surname> <given-names>N.U.</given-names></name><name><surname>Manikandan</surname> <given-names>M.</given-names></name></person-group>. <article-title>Recent advances in nano biosensors: An overview</article-title>. <source>Measurement</source> <volume>236</volume> (<year>2024</year>) <fpage>115073</fpage>. <comment>https://doi.org/10.1016/j.measurement.2024.115073</comment> <pub-id pub-id-type="doi">10.1016/j.measurement.2024.115073</pub-id></mixed-citation></ref>
<ref id="ref89"><label>89.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pal</surname> <given-names>K.</given-names></name><name><surname>Asthana</surname> <given-names>N.</given-names></name><name><surname>Aljabali</surname> <given-names>A.A.</given-names></name><name><surname>Bhardwaj</surname> <given-names>S.K.</given-names></name><name><surname>Kralj</surname> <given-names>S.</given-names></name><name><surname>Penkova</surname> <given-names>A.</given-names></name><name><surname>Thomas</surname> <given-names>S.</given-names></name><name><surname>Zaheer</surname> <given-names>T.</given-names></name><name><surname>Gomes de Souza</surname><given-names>F.</given-names></name></person-group>. <article-title>A critical review on multifunctional smart materials &#x2018;nanographene&#x2019;emerging avenue: nano-imaging and biosensor applications</article-title>. <source>Critical Reviews in Solid State and Materials Sciences</source> <volume>47</volume> (<year>2022</year>) <fpage>691</fpage>-<lpage>707</lpage>. <comment>https://doi.org/10.1080/10408436.2021.1935717</comment> <pub-id pub-id-type="doi">10.1080/10408436.2021.1935717</pub-id></mixed-citation></ref>
<ref id="ref90"><label>90.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Darwish</surname> <given-names>M.A.</given-names></name><name><surname>Abd-Elaziem</surname> <given-names>W.</given-names></name><name><surname>Elsheikh</surname> <given-names>A.</given-names></name><name><surname>Zayed</surname> <given-names>A.A.</given-names></name></person-group>. <article-title>Advancements in nanomaterials for nanosensors: a comprehensive review</article-title>. <source>Nanoscale Advances</source> <volume>6</volume>(<issue>6</issue>) (<year>2024</year>) <fpage>4015</fpage>-<lpage>4046</lpage>. <comment>https://doi.org/10.1039/D4NA00214H</comment> <pub-id pub-id-type="doi">10.1039/D4NA00214H</pub-id></mixed-citation></ref>
<ref id="ref91"><label>91.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Welch</surname> <given-names>E.C.</given-names></name><name><surname>Powell</surname> <given-names>J.M.</given-names></name><name><surname>Clevinger</surname> <given-names>T.B.</given-names></name><name><surname>Fairman</surname> <given-names>A.E.</given-names></name><name><surname>Shukla</surname> <given-names>A.</given-names></name></person-group>. <article-title>Advances in biosensors and diagnostic technologies using nanostructures and nanomaterials</article-title>. <source>Advanced Functional Materials</source> <volume>31</volume> (<year>2021</year>) <fpage>2104126</fpage>. <comment>https://doi.org/10.1002/adfm.202104126</comment> <pub-id pub-id-type="doi">10.1002/adfm.202104126</pub-id></mixed-citation></ref>
<ref id="ref92"><label>92.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kaymaz</surname> <given-names>S.V.</given-names></name><name><surname>Nobar</surname> <given-names>H.M.</given-names></name><name><surname>Sar&#x0131;g&#x00FC;l</surname> <given-names>H.</given-names></name><name><surname>Soylukan</surname> <given-names>C.</given-names></name><name><surname>Aky&#x00FC;z</surname> <given-names>L.</given-names></name><name><surname>Y&#x00FC;ce</surname><given-names>M.</given-names></name></person-group>. <article-title>Nanomaterial surface modification toolkit: Principles, components, recipes, and applications</article-title>. <source>Advances in Colloid and Interface Science</source> <volume>322</volume> (<year>2023</year>) <fpage>103035</fpage>. <comment>https://doi.org/10.1016/j.cis.2023.103035</comment> <pub-id pub-id-type="doi">10.1016/j.cis.2023.103035</pub-id></mixed-citation></ref>
<ref id="ref93"><label>93.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tavakoli</surname> <given-names>H.</given-names></name><name><surname>Mohammadi</surname> <given-names>S.</given-names></name><name><surname>Li</surname> <given-names>X.</given-names></name><name><surname>Fu</surname> <given-names>G.</given-names></name><name><surname>Li</surname> <given-names>X.</given-names></name></person-group>. <article-title>Microfluidic platforms integrated with nano-sensors for point-of-care bioanalysis</article-title>. <source>TrAC Trends in Analytical Chemistry</source> <volume>157</volume> (<year>2022</year>) <fpage>116806</fpage>. <comment>https://doi.org/10.1016/j.trac.2022.116806</comment> <pub-id pub-id-type="doi">10.1016/j.trac.2022.116806</pub-id></mixed-citation></ref>
<ref id="ref94"><label>94.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Adam</surname> <given-names>H.</given-names></name><name><surname>Gopinath</surname> <given-names>S.C.</given-names></name><name><surname>Arshad</surname> <given-names>M.M.</given-names></name><name><surname>Adam</surname> <given-names>T.</given-names></name><name><surname>Hashim</surname> <given-names>U.</given-names></name><name><surname>Sauli</surname> <given-names>Z.</given-names></name><name><surname>Fakhri</surname> <given-names>M.A.</given-names></name><name><surname>Subramaniam</surname> <given-names>S.</given-names></name><name><surname>Chen</surname> <given-names>Y.</given-names></name><name><surname>Sasidharan</surname> <given-names>S.</given-names></name><name><surname>Wu</surname> <given-names>Y.S.</given-names></name></person-group>. <article-title>Integration of microfluidic channel on electrochemical-based nanobiosensors for monoplex and multiplex analyses: an overview</article-title>. <source>Journal of the Taiwan Institute of Chemical Engineers</source> <volume>146</volume> (<year>2023</year>) <fpage>104814</fpage>. <comment>https://doi.org/10.1016/j.jtice.2023.104814</comment> <pub-id pub-id-type="doi">10.1016/j.jtice.2023.104814</pub-id></mixed-citation></ref>
<ref id="ref95"><label>95.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kumari</surname> <given-names>M.</given-names></name><name><surname>Gupta</surname> <given-names>V.</given-names></name><name><surname>Kumar</surname> <given-names>N.</given-names></name><name><surname>Arun</surname> <given-names>R.K.</given-names></name></person-group>. <article-title>Microfluidics-based nanobiosensors for healthcare monitoring</article-title>. <source>Molecular Biotechnology</source> <volume>66</volume> (<year>2024</year>) <fpage>378</fpage>-<lpage>401</lpage>. <comment>https://doi.org/10.1007/s12033-023-00760-9</comment> <pub-id pub-id-type="doi">10.1007/s12033-023-00760-9</pub-id></mixed-citation></ref>
<ref id="ref96"><label>96.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Umar Ibrahim</surname> <given-names>A.</given-names></name><name><surname>Pwavodi</surname> <given-names>P.C.</given-names></name><name><surname>Ozsoz</surname> <given-names>M.</given-names></name><name><surname>Al-Turjman</surname> <given-names>F.</given-names></name><name><surname>Galaya</surname> <given-names>T.</given-names></name><name><surname>Agbo</surname> <given-names>J.J.</given-names></name></person-group>. <article-title>Crispr biosensing and Ai driven tools for detection and prediction of Covid-19</article-title>. <source>Journal of Experimental &#x0026; Theoretical Artificial Intelligence</source> <volume>35</volume> (<year>2023</year>) <fpage>489</fpage>-<lpage>505</lpage>. <comment>https://doi.org/10.1080/0952813X.2021.1952652</comment> <pub-id pub-id-type="doi">10.1080/0952813X.2021.1952652</pub-id></mixed-citation></ref>
<ref id="ref97"><label>97.</label> <mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Irkham</surname> <given-names>I.</given-names></name><name><surname>Ibrahim</surname> <given-names>A.U.</given-names></name><name><surname>Pwavodi</surname> <given-names>P.C.</given-names></name><name><surname>Nwekwo</surname> <given-names>C.W.</given-names></name><name><surname>Hartati</surname> <given-names>Y.W.</given-names></name></person-group>. <article-title>CRISPR-based biosensor for the detection of Marburg and Ebola virus</article-title>. <source>Sensing and Bio-Sensing Research</source> <volume>43</volume> (<year>2024</year>) <fpage>100601</fpage>. <comment>https://doi.org/10.1016/j.sbsr.2023.100601</comment> <pub-id pub-id-type="doi">10.1016/j.sbsr.2023.100601</pub-id></mixed-citation></ref>
</ref-list>
</back>
</article>