Izvorni znanstveni članak

Functional Diagnostics of the Temporomandibular Joint with a String-Condylocomp

Branko Kašaj ; Neustadt, Hauptstrasse 99, SR Njemačka
Vjekoslav Jerolimov ; Department of Prosthodontics, University Hospital
Vlado Carek ; Department of Prosthodontics, University Hospital

Puni tekst: hrvatski, pdf (13 MB) str. 49-54 preuzimanja: 421* citiraj
APA 6th Edition
Kašaj, B., Jerolimov, V. i Carek, V. (1996). Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom. Acta stomatologica Croatica, 30 (1), 49-54. Preuzeto s https://hrcak.srce.hr/98301
MLA 8th Edition
Kašaj, Branko, et al. "Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom." Acta stomatologica Croatica, vol. 30, br. 1, 1996, str. 49-54. https://hrcak.srce.hr/98301. Citirano 21.09.2021.
Chicago 17th Edition
Kašaj, Branko, Vjekoslav Jerolimov i Vlado Carek. "Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom." Acta stomatologica Croatica 30, br. 1 (1996): 49-54. https://hrcak.srce.hr/98301
Harvard
Kašaj, B., Jerolimov, V., i Carek, V. (1996). 'Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom', Acta stomatologica Croatica, 30(1), str. 49-54. Preuzeto s: https://hrcak.srce.hr/98301 (Datum pristupa: 21.09.2021.)
Vancouver
Kašaj B, Jerolimov V, Carek V. Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom. Acta stomatologica Croatica [Internet]. 1996 [pristupljeno 21.09.2021.];30(1):49-54. Dostupno na: https://hrcak.srce.hr/98301
IEEE
B. Kašaj, V. Jerolimov i V. Carek, "Funkcijska dijagnostika čeljusnoga zgloba sa string - condylocompom", Acta stomatologica Croatica, vol.30, br. 1, str. 49-54, 1996. [Online]. Dostupno na: https://hrcak.srce.hr/98301. [Citirano: 21.09.2021.]

Sažetak
Condylocomp LR 3 (Dentron, Höchberg, Germany) is an electronic system for threedimensional, simultaneous registration o f the movement of the lower jaw. It is attached to a personal computer and
enables simultaneous graphic registration and control on a monitor.
Graphic presentation and measured data are filled and can be shown
on the monitor and analyzed whenever necessary. This system precisely calculates: rotation centre of both condyles condylar axis, slope of the condyle path, Bennett’s angle and Bennett’s movement, position of distraction of compression of the condyle, Posselt’s diagram and the incision angle. The system is helpful in the field o f functional diagnostics of the stomatognathic system. Individual programming of the articulator is simplified.

Ključne riječi
Gnathology; functional diagnostics; electronic condylography