hrcak mascot   Srce   HID

Prethodno priopćenje
https://doi.org/10.15644/asc47/1/7

Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje

Lana Bergman Gašparić ; Zavod za fiksnu protetiku Stomatološkog fakulteta Sveučilišta u Zagrebu, Hrvatska

Puni tekst: hrvatski, pdf (259 KB) str. 45-50 preuzimanja: 216* citiraj
APA 6th Edition
Bergman Gašparić, L. (2013). Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje. Acta stomatologica Croatica, 47 (1), 45-50. https://doi.org/10.15644/asc47/1/7
MLA 8th Edition
Bergman Gašparić, Lana. "Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje." Acta stomatologica Croatica, vol. 47, br. 1, 2013, str. 45-50. https://doi.org/10.15644/asc47/1/7. Citirano 25.02.2021.
Chicago 17th Edition
Bergman Gašparić, Lana. "Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje." Acta stomatologica Croatica 47, br. 1 (2013): 45-50. https://doi.org/10.15644/asc47/1/7
Harvard
Bergman Gašparić, L. (2013). 'Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje', Acta stomatologica Croatica, 47(1), str. 45-50. https://doi.org/10.15644/asc47/1/7
Vancouver
Bergman Gašparić L. Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje. Acta stomatologica Croatica [Internet]. 2013 [pristupljeno 25.02.2021.];47(1):45-50. https://doi.org/10.15644/asc47/1/7
IEEE
L. Bergman Gašparić, "Ispitivanje povezanosti hrapavosti površine cirkonij-oksidne keramike i vezne čvrstoće s obložnom keramikom: prethodno priopćenje", Acta stomatologica Croatica, vol.47, br. 1, str. 45-50, 2013. [Online]. https://doi.org/10.15644/asc47/1/7
Puni tekst: engleski, pdf (259 KB) str. 45-50 preuzimanja: 390* citiraj
APA 6th Edition
Bergman Gašparić, L. (2013). Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report. Acta stomatologica Croatica, 47 (1), 45-50. https://doi.org/10.15644/asc47/1/7
MLA 8th Edition
Bergman Gašparić, Lana. "Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report." Acta stomatologica Croatica, vol. 47, br. 1, 2013, str. 45-50. https://doi.org/10.15644/asc47/1/7. Citirano 25.02.2021.
Chicago 17th Edition
Bergman Gašparić, Lana. "Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report." Acta stomatologica Croatica 47, br. 1 (2013): 45-50. https://doi.org/10.15644/asc47/1/7
Harvard
Bergman Gašparić, L. (2013). 'Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report', Acta stomatologica Croatica, 47(1), str. 45-50. https://doi.org/10.15644/asc47/1/7
Vancouver
Bergman Gašparić L. Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report. Acta stomatologica Croatica [Internet]. 2013 [pristupljeno 25.02.2021.];47(1):45-50. https://doi.org/10.15644/asc47/1/7
IEEE
L. Bergman Gašparić, "Correlation between Surface Roughness and Shear Bond Strength in Zirconia Veneering Ceramics: a Preliminary Report", Acta stomatologica Croatica, vol.47, br. 1, str. 45-50, 2013. [Online]. https://doi.org/10.15644/asc47/1/7

Sažetak
Delaminacija i chipping obložne keramike opisani su kao najčešći uzroci za neuspjeh terapije cirkonij-oksidnim nadomjescima. Svrha: Željela se ustanoviti povezanost između hrapavosti površine jezgre od cirkonijeva oksida i vezne čvrstoće obložne keramike. Materijali i postupci: Sinterirano je ukupno 10 uzoraka koji su bili podijeljeni u dvije skupine. Uzorci prve skupine polirani su, a oni iz druge polirani i pjeskareni. Nakon obrade površine cirkonij-oksidne jezgre napečena je obložna keramika debljine tri milimetra. Tako pripremljeni uzorci uloženi su u PTFE-kalupe s pomoću smole PMMA i izloženi smičnoj sili do pucanja (univerzalna kidalica). Hrapavost površine izmjerena je prije napečenja obložne keramike instrumentom s ticalom Perthometer S8P, te su zabilježene vrijednosti Ra i Z. Rezultati: Polirani i pjeskareni uzorci imali su znatno hrapaviju površinu (p<0,01) te su pokazali mnogo više vrijednosti vezne čvrstoće (p<0,01) od samo poliranih uzoraka. Zaključak: Utvrđena je značajna povezanost između vrijednosti hrapavosti površine cirkonij-
oksidne jezgre i vezne čvrstoće (r=xy, p<0,01) s obložnom eramikom.

Ključne riječi
stomatološke ljuske; cirkonij-oksid; keramika; svojstva površina; smična sila; dentalni cementi

Hrčak ID: 98661

URI
https://hrcak.srce.hr/98661

[engleski]

Posjeta: 911 *