hrcak mascot   Srce   HID

Izvorni znanstveni članak

Effect of Saliva and Base Size on Complete Prosthesis Adhesion

Vlado Carek ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia
Mirjana Janušić-Antončić ; Privatna zubna ordinacija, Varaždinske toplice, Varaždin, Hrvatska
Vjekoslav Jerolimov ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia

Puni tekst: hrvatski, pdf (9 MB) str. 167-173 preuzimanja: 375* citiraj
APA 6th Edition
Carek, V., Janušić-Antončić, M. i Jerolimov, V. (1995). Utjecaj sline i veličine baze na adheziju potpune proteze. Acta stomatologica Croatica, 29 (3), 167-173. Preuzeto s https://hrcak.srce.hr/99185
MLA 8th Edition
Carek, Vlado, et al. "Utjecaj sline i veličine baze na adheziju potpune proteze." Acta stomatologica Croatica, vol. 29, br. 3, 1995, str. 167-173. https://hrcak.srce.hr/99185. Citirano 28.02.2021.
Chicago 17th Edition
Carek, Vlado, Mirjana Janušić-Antončić i Vjekoslav Jerolimov. "Utjecaj sline i veličine baze na adheziju potpune proteze." Acta stomatologica Croatica 29, br. 3 (1995): 167-173. https://hrcak.srce.hr/99185
Harvard
Carek, V., Janušić-Antončić, M., i Jerolimov, V. (1995). 'Utjecaj sline i veličine baze na adheziju potpune proteze', Acta stomatologica Croatica, 29(3), str. 167-173. Preuzeto s: https://hrcak.srce.hr/99185 (Datum pristupa: 28.02.2021.)
Vancouver
Carek V, Janušić-Antončić M, Jerolimov V. Utjecaj sline i veličine baze na adheziju potpune proteze. Acta stomatologica Croatica [Internet]. 1995 [pristupljeno 28.02.2021.];29(3):167-173. Dostupno na: https://hrcak.srce.hr/99185
IEEE
V. Carek, M. Janušić-Antončić i V. Jerolimov, "Utjecaj sline i veličine baze na adheziju potpune proteze", Acta stomatologica Croatica, vol.29, br. 3, str. 167-173, 1995. [Online]. Dostupno na: https://hrcak.srce.hr/99185. [Citirano: 28.02.2021.]

Sažetak
The aim of the study was to assess the value of retention adhesion power in complete prostheses. Measurements were performed on acrylate plates o f20.25 and 38.482 area and 3 mm thick. Six different concentrations of artifical saliva specially designed instruments. The following variable were determined: area of acrylate plates, saliva thickness and rate of separation of the areas tested.
The values of adhesion powers examined are expressed in newtons
(N). Statistical processing of the results obtained included calculation of arithmetical means, standard deviations, minimal and maximal variable values, coefficients of variability and value of covariance.
The results and discussion points to a conclusion that the mean value of adhesion retention power for the tested sample wa 21.36 N. Great differences were recorded between particular measurements, depending on the acrylate plate area and saliva concentration.The mean retention adhesion power in the samples of 38.38 and 20.25 cm2 area was 29.52 and 15.34 N, respectively.