hrcak mascot   Srce   HID

Izvorni znanstveni članak

Distribution of Active Plate Forces by Electrical Resistance Strain Gauge Transducers

Mladen Šlaj ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia
Andrej Meniga ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia
Darije Plančak ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia

Puni tekst: hrvatski, pdf (10 MB) str. 109-116 preuzimanja: 176* citiraj
APA 6th Edition
Šlaj, M., Meniga, A. i Plančak, D. (1992). Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima. Acta stomatologica Croatica, 26 (2), 109-116. Preuzeto s https://hrcak.srce.hr/100659
MLA 8th Edition
Šlaj, Mladen, et al. "Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima." Acta stomatologica Croatica, vol. 26, br. 2, 1992, str. 109-116. https://hrcak.srce.hr/100659. Citirano 27.02.2021.
Chicago 17th Edition
Šlaj, Mladen, Andrej Meniga i Darije Plančak. "Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima." Acta stomatologica Croatica 26, br. 2 (1992): 109-116. https://hrcak.srce.hr/100659
Harvard
Šlaj, M., Meniga, A., i Plančak, D. (1992). 'Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima', Acta stomatologica Croatica, 26(2), str. 109-116. Preuzeto s: https://hrcak.srce.hr/100659 (Datum pristupa: 27.02.2021.)
Vancouver
Šlaj M, Meniga A, Plančak D. Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima. Acta stomatologica Croatica [Internet]. 1992 [pristupljeno 27.02.2021.];26(2):109-116. Dostupno na: https://hrcak.srce.hr/100659
IEEE
M. Šlaj, A. Meniga i D. Plančak, "Raspodjela sila aktivnih ploča utvrđena elektrootporničkim davačima", Acta stomatologica Croatica, vol.26, br. 2, str. 109-116, 1992. [Online]. Dostupno na: https://hrcak.srce.hr/100659. [Citirano: 27.02.2021.]

Sažetak
Distribution o f forces on two active plate modifications, i.e. with symmetrically and asymmetrically built-in extensor for transversal extension, was experimentally analyzed. Besides the size o f forces exerted by the device, dependence o f the force magnitude on the anchorage, i.e. on the way o f the screw insertion and acrylate cut, was also determined. Theoretical analysis o f the device showed that greater force should be expected on the side with lower total active surface. This hypothesis was also proven by measurement results.A substantially greater force o f about 10 N was recorded on the side where the screw was shifted, whereas a force o f only 6.5 N was registered on the other side. The forces recorded on a symmetrically
cut plate were almost identical on the two sides. A t the beginning o f measurements, values o f about 8 N were bilaterally registered and thereafter observed to decline to about 5 N.

Ključne riječi
orthodontic forces; strain gauge transducers