hrcak mascot   Srce   HID

Preliminary communication

ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS

Goran Micev ; Euro Facade Tech
Tomislav Mrakovčić   ORCID icon orcid.org/0000-0003-1179-2771 ; Tehnički fakultet

Fulltext: english, pdf (3 MB) pages 21-37 downloads: 762* cite
APA 6th Edition
Micev, G. & Mrakovčić, T. (2013). ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS. Pomorstvo, 27 (1), 21-37. Retrieved from https://hrcak.srce.hr/103940
MLA 8th Edition
Micev, Goran and Tomislav Mrakovčić. "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS." Pomorstvo, vol. 27, no. 1, 2013, pp. 21-37. https://hrcak.srce.hr/103940. Accessed 23 Sep. 2021.
Chicago 17th Edition
Micev, Goran and Tomislav Mrakovčić. "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS." Pomorstvo 27, no. 1 (2013): 21-37. https://hrcak.srce.hr/103940
Harvard
Micev, G., and Mrakovčić, T. (2013). 'ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS', Pomorstvo, 27(1), pp. 21-37. Available at: https://hrcak.srce.hr/103940 (Accessed 23 September 2021)
Vancouver
Micev G, Mrakovčić T. ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS. Pomorstvo [Internet]. 2013 [cited 2021 September 23];27(1):21-37. Available from: https://hrcak.srce.hr/103940
IEEE
G. Micev and T. Mrakovčić, "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS", Pomorstvo, vol.27, no. 1, pp. 21-37, 2013. [Online]. Available: https://hrcak.srce.hr/103940. [Accessed: 23 September 2021]
Fulltext: croatian, pdf (3 MB) pages 21-37 downloads: 305* cite
APA 6th Edition
Micev, G. & Mrakovčić, T. (2013). ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI. Pomorstvo, 27 (1), 21-37. Retrieved from https://hrcak.srce.hr/103940
MLA 8th Edition
Micev, Goran and Tomislav Mrakovčić. "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI." Pomorstvo, vol. 27, no. 1, 2013, pp. 21-37. https://hrcak.srce.hr/103940. Accessed 23 Sep. 2021.
Chicago 17th Edition
Micev, Goran and Tomislav Mrakovčić. "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI." Pomorstvo 27, no. 1 (2013): 21-37. https://hrcak.srce.hr/103940
Harvard
Micev, G., and Mrakovčić, T. (2013). 'ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI', Pomorstvo, 27(1), pp. 21-37. Available at: https://hrcak.srce.hr/103940 (Accessed 23 September 2021)
Vancouver
Micev G, Mrakovčić T. ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI. Pomorstvo [Internet]. 2013 [cited 2021 September 23];27(1):21-37. Available from: https://hrcak.srce.hr/103940
IEEE
G. Micev and T. Mrakovčić, "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI", Pomorstvo, vol.27, no. 1, pp. 21-37, 2013. [Online]. Available: https://hrcak.srce.hr/103940. [Accessed: 23 September 2021]

Abstracts
In this paper, the analysis of the ship piping installation effect on the possibility of mounting and on the operation of pumps was performed. Smaller or greater deviations from the project dimensions which complicate the mounting of the equipment, such as pumps or valves, appear frequently during the piping installation. Additional works on ship piping inevitably mean high additional costs and overrun of time limits scheduled for the piping installation. On the other hand, incorrectly mounted pump will have significantly shorter working life and if pump malfunction happens in an unfavourable moment, the consequences could be serious. Methodology, by which it could be verified if the measured piping deviation is acceptable before the equipment mounting, could yield in significant savings during the piping installation and exploitation. Loads that affect on the pump housing upon incorrect mounting could be calculated precisely by the application of the finite element method. In this paper, the finite element method analysis was performed on the example of a chosen segment of the ship piping where the pump housing loads were calculated as the function of the piping deviation from the project dimensions. On the basis of the obtained results, it is possible to evaluate whether the pre-existing condition of piping could be acceptable or not. Directives for the continuation and systematization of this research according to the needs and requirements of a specific technological piping production and installation process are given in the conclusion.

Keywords
ship piping; pumps; stress analysis; finite element method

Hrčak ID: 103940

URI
https://hrcak.srce.hr/103940

[croatian]

Visits: 1.445 *