ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS

Goran Micev ; Euro Facade Tech
Tomislav Mrakovčić   ORCID icon orcid.org/0000-0003-1179-2771 ; Tehnički fakultet

Puni tekst: engleski, pdf (3 MB) str. 21-37 preuzimanja: 762* citiraj
APA 6th Edition
Micev, G. i Mrakovčić, T. (2013). ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS. Pomorstvo, 27 (1), 21-37. Preuzeto s https://hrcak.srce.hr/103940
MLA 8th Edition
Micev, Goran i Tomislav Mrakovčić. "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS." Pomorstvo, vol. 27, br. 1, 2013, str. 21-37. https://hrcak.srce.hr/103940. Citirano 17.09.2021.
Chicago 17th Edition
Micev, Goran i Tomislav Mrakovčić. "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS." Pomorstvo 27, br. 1 (2013): 21-37. https://hrcak.srce.hr/103940
Harvard
Micev, G., i Mrakovčić, T. (2013). 'ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS', Pomorstvo, 27(1), str. 21-37. Preuzeto s: https://hrcak.srce.hr/103940 (Datum pristupa: 17.09.2021.)
Vancouver
Micev G, Mrakovčić T. ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS. Pomorstvo [Internet]. 2013 [pristupljeno 17.09.2021.];27(1):21-37. Dostupno na: https://hrcak.srce.hr/103940
IEEE
G. Micev i T. Mrakovčić, "ANALYSIS OF THE SHIP PIPING INSTALLATION EFFECT ON THE MOUNTING AND OPERATION OF PUMPS", Pomorstvo, vol.27, br. 1, str. 21-37, 2013. [Online]. Dostupno na: https://hrcak.srce.hr/103940. [Citirano: 17.09.2021.]
Puni tekst: hrvatski, pdf (3 MB) str. 21-37 preuzimanja: 305* citiraj
APA 6th Edition
Micev, G. i Mrakovčić, T. (2013). ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI. Pomorstvo, 27 (1), 21-37. Preuzeto s https://hrcak.srce.hr/103940
MLA 8th Edition
Micev, Goran i Tomislav Mrakovčić. "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI." Pomorstvo, vol. 27, br. 1, 2013, str. 21-37. https://hrcak.srce.hr/103940. Citirano 17.09.2021.
Chicago 17th Edition
Micev, Goran i Tomislav Mrakovčić. "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI." Pomorstvo 27, br. 1 (2013): 21-37. https://hrcak.srce.hr/103940
Harvard
Micev, G., i Mrakovčić, T. (2013). 'ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI', Pomorstvo, 27(1), str. 21-37. Preuzeto s: https://hrcak.srce.hr/103940 (Datum pristupa: 17.09.2021.)
Vancouver
Micev G, Mrakovčić T. ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI. Pomorstvo [Internet]. 2013 [pristupljeno 17.09.2021.];27(1):21-37. Dostupno na: https://hrcak.srce.hr/103940
IEEE
G. Micev i T. Mrakovčić, "ANALIZA UTJECAJA IZVEDBE BRODSKIH CJEVOVODA NA MONTAŽU I RAD PUMPI", Pomorstvo, vol.27, br. 1, str. 21-37, 2013. [Online]. Dostupno na: https://hrcak.srce.hr/103940. [Citirano: 17.09.2021.]

Sažetak
In this paper, the analysis of the ship piping installation effect on the possibility of mounting and on the operation of pumps was performed. Smaller or greater deviations from the project dimensions which complicate the mounting of the equipment, such as pumps or valves, appear frequently during the piping installation. Additional works on ship piping inevitably mean high additional costs and overrun of time limits scheduled for the piping installation. On the other hand, incorrectly mounted pump will have significantly shorter working life and if pump malfunction happens in an unfavourable moment, the consequences could be serious. Methodology, by which it could be verified if the measured piping deviation is acceptable before the equipment mounting, could yield in significant savings during the piping installation and exploitation. Loads that affect on the pump housing upon incorrect mounting could be calculated precisely by the application of the finite element method. In this paper, the finite element method analysis was performed on the example of a chosen segment of the ship piping where the pump housing loads were calculated as the function of the piping deviation from the project dimensions. On the basis of the obtained results, it is possible to evaluate whether the pre-existing condition of piping could be acceptable or not. Directives for the continuation and systematization of this research according to the needs and requirements of a specific technological piping production and installation process are given in the conclusion.

Ključne riječi
ship piping; pumps; stress analysis; finite element method

Hrčak ID: 103940