Skoči na glavni sadržaj

Stručni rad

Causes of collapse and remedy of steel-tank roof structures

Franjo Turčić
Ivo Luketina
Mladen Plišić


Puni tekst: hrvatski pdf 341 Kb

str. 21-27

preuzimanja: 859

citiraj


Sažetak

Results obtained during analysis of the causes of collapse of roof structures of steel tanks are presented, and solutions applied during remedial activities are described. Two heating oil tanks in Zagreb, whose steel structures partly caved in, were used as an example. It was established in the analysis that several errors were made in the initial design, and that these errors concern the completeness and accuracy of static computations for the load bearing structure (inadequate static system and inappropriate load combination).

Ključne riječi

steel tank; roof structure; collapse; design; static system; load; remedy

Hrčak ID:

10125

URI

https://hrcak.srce.hr/10125

Datum izdavanja:

12.2.2007.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.901 *