Izvorni znanstveni članak

[Determination of the dental magnet retention forces]

Vlado Carek ; Zavod za mobilnu protetiku Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb
Daniel Đurek ; Institut za fiziku Sveučilišta u Zagrebu, Zagreb
Vladimir Lapter ; Zavod za ortodonciju Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb

Puni tekst: hrvatski, pdf (7 MB) str. 121-128 preuzimanja: 247* citiraj
APA 6th Edition
Carek, V., Đurek, D. i Lapter, V. (1986). Mjerenje retencijskih sila dentalnih magneta. Acta stomatologica Croatica, 20 (suppl), 121-128. Preuzeto s https://hrcak.srce.hr/106814
MLA 8th Edition
Carek, Vlado, et al. "Mjerenje retencijskih sila dentalnih magneta." Acta stomatologica Croatica, vol. 20, br. suppl, 1986, str. 121-128. https://hrcak.srce.hr/106814. Citirano 30.09.2020.
Chicago 17th Edition
Carek, Vlado, Daniel Đurek i Vladimir Lapter. "Mjerenje retencijskih sila dentalnih magneta." Acta stomatologica Croatica 20, br. suppl (1986): 121-128. https://hrcak.srce.hr/106814
Harvard
Carek, V., Đurek, D., i Lapter, V. (1986). 'Mjerenje retencijskih sila dentalnih magneta', Acta stomatologica Croatica, 20(suppl), str. 121-128. Preuzeto s: https://hrcak.srce.hr/106814 (Datum pristupa: 30.09.2020.)
Vancouver
Carek V, Đurek D, Lapter V. Mjerenje retencijskih sila dentalnih magneta. Acta stomatologica Croatica [Internet]. 1986 [pristupljeno 30.09.2020.];20(suppl):121-128. Dostupno na: https://hrcak.srce.hr/106814
IEEE
V. Carek, D. Đurek i V. Lapter, "Mjerenje retencijskih sila dentalnih magneta", Acta stomatologica Croatica, vol.20, br. suppl, str. 121-128, 1986. [Online]. Dostupno na: https://hrcak.srce.hr/106814. [Citirano: 30.09.2020.]

Sažetak
The use of high-attraction magnetic alloys as a means of retention has recently been on an increase. Fof this purpose, a device for the dental magnet retention determination has been developed. This device allows the magnet attraction, with or without the presence of lateral forces, to be measured. Attraction force valaues of the magnets of any size and of magnetic alloys used in mobile prosthodontics, orthodontics, and oral and dentofacial surgery (Behrman1, Cerny2), can thus be asseassed. Magnetic dynamometer allows retention between two permanent magnets to be determined and precisely assessed for different relative distances and positions. All the parts of the device exept spiral coiIs are made of a non-ferromagnetic material to avoid any disturbances during measurements. The results obtained in the study of dental magnet retention have revealed the highest magnetic power without any lateral force influence to be 157.9, 117.1 and 211.4 ponds for distances od 1, 1.6 and 0.4 mm, respectively. Maximal force between two dental SmC05 magnets amounts to 373 ponds at the distance of 0.4 mm and with magnet dimension of 6/3x7.1/3 mm.

Ključne riječi
Retention forces; magnets; dynamometer

Hrčak ID: 106814

URI
https://hrcak.srce.hr/106814