hrcak mascot   Srce   HID

Sažetak sa skupa

An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study

R. Gržić
I. Uhač
I. Jonjić
Z. Delić
J. Borčić
M. Muhvić-Urek

Puni tekst: engleski, pdf (45 KB) str. 346-346 preuzimanja: 294* citiraj
APA 6th Edition
Gržić, R., Uhač, I., Jonjić, I., Delić, Z., Borčić, J. i Muhvić-Urek, M. (2002). An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study. Acta stomatologica Croatica, 36 (3), 346-346. Preuzeto s https://hrcak.srce.hr/10234
MLA 8th Edition
Gržić, R., et al. "An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study." Acta stomatologica Croatica, vol. 36, br. 3, 2002, str. 346-346. https://hrcak.srce.hr/10234. Citirano 05.12.2020.
Chicago 17th Edition
Gržić, R., I. Uhač, I. Jonjić, Z. Delić, J. Borčić i M. Muhvić-Urek. "An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study." Acta stomatologica Croatica 36, br. 3 (2002): 346-346. https://hrcak.srce.hr/10234
Harvard
Gržić, R., et al. (2002). 'An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study', Acta stomatologica Croatica, 36(3), str. 346-346. Preuzeto s: https://hrcak.srce.hr/10234 (Datum pristupa: 05.12.2020.)
Vancouver
Gržić R, Uhač I, Jonjić I, Delić Z, Borčić J, Muhvić-Urek M. An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study. Acta stomatologica Croatica [Internet]. 2002 [pristupljeno 05.12.2020.];36(3):346-346. Dostupno na: https://hrcak.srce.hr/10234
IEEE
R. Gržić, I. Uhač, I. Jonjić, Z. Delić, J. Borčić i M. Muhvić-Urek, "An Evaluation of the Quality of Tooth Preparation with Intraoral Parallometer-Axisgraph - Pilot Study", Acta stomatologica Croatica, vol.36, br. 3, str. 346-346, 2002. [Online]. Dostupno na: https://hrcak.srce.hr/10234. [Citirano: 05.12.2020.]

Sažetak
Measuring of the axial angle in practice shows an average angle of 20 degrees. The result of the high taper angles is a nonsatisfactory resistance form in 22.5% cases. The purpose was to examine the efficiency of the Jonjić oral parallelometer, known as the "AXISGRAPH", with respect to basic ergonomic rules, leading to savings in working energy and time and an increase in the quality
of the preparation.
METHODS: On the basis of clinical cases models were made of the upper and of the lower jaw of acrylic resin. The practitioner, who has 10 years experience, initially prepared each model set in a KAWO-EWL model, conventionally using freehand preparation, and then with
an Axisgraph. Both models were in the same condition. Comparison was made between the time required for preparation, working energy used, and the quality of the preparation. The quality of the preparation was determined using the axial angle of the prepared tooth, measured by the method described in Jonjic's dissertation.
RESULTS: The freehand preparation took 80 minutes while preparation with the Axisgraph took 50 minutes. The average angle in freehand preparation was 15.03 degrees while, (the average angle of preparation was 10.4 degrees) using Axisgraph, and in 30 minutes less time than the freehand preparation.
CONCLUSION: Preparation with the Axisgraph significantly saves time on preparation and allows better quality for the prepared tooth.