hrcak mascot   Srce   HID

Pregledni rad
https://doi.org/10.11613/BM.2013.034

Exhaled breath condensate – from an analytical point of view

Slavica Dodig   ORCID icon orcid.org/0000-0002-3419-5171 ; Department of Clinical Laboratory Diagnosis, Srebrnjak Children’s Hospital, Zagreb, Croatia
Ivana Čepelak ; Department of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry, University of Zagreb, Zagreb, Croatia

Puni tekst: engleski, pdf (255 KB) str. 281-295 preuzimanja: 421* citiraj
APA 6th Edition
Dodig, S. i Čepelak, I. (2013). Exhaled breath condensate – from an analytical point of view. Biochemia Medica, 23 (3), 281-295. https://doi.org/10.11613/BM.2013.034
MLA 8th Edition
Dodig, Slavica i Ivana Čepelak. "Exhaled breath condensate – from an analytical point of view." Biochemia Medica, vol. 23, br. 3, 2013, str. 281-295. https://doi.org/10.11613/BM.2013.034. Citirano 26.01.2021.
Chicago 17th Edition
Dodig, Slavica i Ivana Čepelak. "Exhaled breath condensate – from an analytical point of view." Biochemia Medica 23, br. 3 (2013): 281-295. https://doi.org/10.11613/BM.2013.034
Harvard
Dodig, S., i Čepelak, I. (2013). 'Exhaled breath condensate – from an analytical point of view', Biochemia Medica, 23(3), str. 281-295. https://doi.org/10.11613/BM.2013.034
Vancouver
Dodig S, Čepelak I. Exhaled breath condensate – from an analytical point of view. Biochemia Medica [Internet]. 2013 [pristupljeno 26.01.2021.];23(3):281-295. https://doi.org/10.11613/BM.2013.034
IEEE
S. Dodig i I. Čepelak, "Exhaled breath condensate – from an analytical point of view", Biochemia Medica, vol.23, br. 3, str. 281-295, 2013. [Online]. https://doi.org/10.11613/BM.2013.034

Sažetak
Over the past three decades, the goal of many researchers is analysis of exhaled breath condensate (EBC) as noninvasively obtained sample. A total quality in laboratory diagnostic processes in EBC analysis was investigated: pre-analytical (formation, collection, storage of EBC), analytical (sensitivity of applied methods, standardization) and post-analytical (interpretation of results) phases. EBC analysis is still used as a research tool. Limitations referred to pre-analytical, analytical, and post-analytical phases of EBC analysis are numerous, e.g. low concentrations of EBC constituents, single-analyte methods lack in sensitivity, and multi-analyte has not been fully explored, and reference values are not established. When all, pre-analytical, analytical and post-analytical requirements are met, EBC biomarkers as well as biomarker patterns can be selected and EBC analysis can hopefully be used in clinical practice, in both, the diagnosis and in the longitudinal follow-up of patients, resulting in better outcome of disease.