Izvorni znanstveni članak

Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis

Arsen Pavić ; Clinical Hospital Center Split, Spinčićeva 5, 21000 Split, Croatia
Janoš Kodvanj ; Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 5, 10000 Zagreb, Croatia
Martin Surjak ; Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 5, 10000 Zagreb, Croatia

Puni tekst: hrvatski, pdf (2 MB) str. 995-999 preuzimanja: 377* citiraj
APA 6th Edition
Pavić, A., Kodvanj, J. i Surjak, M. (2013). Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis. Tehnički vjesnik, 20 (6), 995-999. Preuzeto s https://hrcak.srce.hr/112318
MLA 8th Edition
Pavić, Arsen, et al. "Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis." Tehnički vjesnik, vol. 20, br. 6, 2013, str. 995-999. https://hrcak.srce.hr/112318. Citirano 18.09.2020.
Chicago 17th Edition
Pavić, Arsen, Janoš Kodvanj i Martin Surjak. "Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis." Tehnički vjesnik 20, br. 6 (2013): 995-999. https://hrcak.srce.hr/112318
Harvard
Pavić, A., Kodvanj, J., i Surjak, M. (2013). 'Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis', Tehnički vjesnik, 20(6), str. 995-999. Preuzeto s: https://hrcak.srce.hr/112318 (Datum pristupa: 18.09.2020.)
Vancouver
Pavić A, Kodvanj J, Surjak M. Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis. Tehnički vjesnik [Internet]. 2013 [pristupljeno 18.09.2020.];20(6):995-999. Dostupno na: https://hrcak.srce.hr/112318
IEEE
A. Pavić, J. Kodvanj i M. Surjak, "Određivanje stabilnosti novog vanjskog fiksatora primjenom mjernog sustava Aramis", Tehnički vjesnik, vol.20, br. 6, str. 995-999, 2013. [Online]. Dostupno na: https://hrcak.srce.hr/112318. [Citirano: 18.09.2020.]
Puni tekst: engleski, pdf (2 MB) str. 995-999 preuzimanja: 213* citiraj
APA 6th Edition
Pavić, A., Kodvanj, J. i Surjak, M. (2013). Determining the stability of novel external fixator by using measuring system Aramis. Tehnički vjesnik, 20 (6), 995-999. Preuzeto s https://hrcak.srce.hr/112318
MLA 8th Edition
Pavić, Arsen, et al. "Determining the stability of novel external fixator by using measuring system Aramis." Tehnički vjesnik, vol. 20, br. 6, 2013, str. 995-999. https://hrcak.srce.hr/112318. Citirano 18.09.2020.
Chicago 17th Edition
Pavić, Arsen, Janoš Kodvanj i Martin Surjak. "Determining the stability of novel external fixator by using measuring system Aramis." Tehnički vjesnik 20, br. 6 (2013): 995-999. https://hrcak.srce.hr/112318
Harvard
Pavić, A., Kodvanj, J., i Surjak, M. (2013). 'Determining the stability of novel external fixator by using measuring system Aramis', Tehnički vjesnik, 20(6), str. 995-999. Preuzeto s: https://hrcak.srce.hr/112318 (Datum pristupa: 18.09.2020.)
Vancouver
Pavić A, Kodvanj J, Surjak M. Determining the stability of novel external fixator by using measuring system Aramis. Tehnički vjesnik [Internet]. 2013 [pristupljeno 18.09.2020.];20(6):995-999. Dostupno na: https://hrcak.srce.hr/112318
IEEE
A. Pavić, J. Kodvanj i M. Surjak, "Determining the stability of novel external fixator by using measuring system Aramis", Tehnički vjesnik, vol.20, br. 6, str. 995-999, 2013. [Online]. Dostupno na: https://hrcak.srce.hr/112318. [Citirano: 18.09.2020.]

Sažetak
Vanjski fiksatori koriste se za liječenje otvorenih i zatvorenih prijeloma dugih kostiju. Krutost i čvrstoća fiksatora uvelike utječu na konačan ishod liječenja. Odgovarajuća stabilnost koštanih ulomaka omogućuje bolje cijeljenje prijeloma i bržu rehabilitaciju pacijenta. Cilj ovog istraživanja bila je procjena biomehaničke stabilnosti novokonstruiranog unilateralnog vanjskog fiksatora za prijelome proksimalne tibije. S ciljem usporedbe svojstava prototipa novog fiksatora s vanjskim fiksatorom Orthofix, koji se često upotrebljava u kliničkoj praksi, provedena su statička i dinamička ispitivanja. Pri statičkom ispitivanju uzorci su opterećeni aksijalno i na savijanje, a pomaci su određeni bezkontaktnim optičkim mjernim sustavom Aramis. Rezultati su pokazali da su biomehanička svojstva nove konstrukcije bolja kod savijanja, dok se konvencionalni vanjski fiksator pokazao boljim pri aksijalnom opterećenju. Pri cikličkom ispitivanju nije bilo značajne razlike u rezultatima.

Ključne riječi
optički sustav Aramis; stabilnost; vanjski fiksator