hrcak mascot   Srce   HID

Izvorni znanstveni članak

Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola

Tomislav Ivaniš
Jasenka Živko-Babić
Biserka Lazić
Josip Pandurić

Puni tekst: hrvatski, pdf (73 KB) str. 5-10 preuzimanja: 964* citiraj
APA 6th Edition
Ivaniš, T., Živko-Babić, J., Lazić, B. i Pandurić, J. (2000). Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola. Acta stomatologica Croatica, 34 (1), 5-10. Preuzeto s https://hrcak.srce.hr/11031
MLA 8th Edition
Ivaniš, Tomislav, et al. "Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola." Acta stomatologica Croatica, vol. 34, br. 1, 2000, str. 5-10. https://hrcak.srce.hr/11031. Citirano 04.03.2021.
Chicago 17th Edition
Ivaniš, Tomislav, Jasenka Živko-Babić, Biserka Lazić i Josip Pandurić. "Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola." Acta stomatologica Croatica 34, br. 1 (2000): 5-10. https://hrcak.srce.hr/11031
Harvard
Ivaniš, T., et al. (2000). 'Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola', Acta stomatologica Croatica, 34(1), str. 5-10. Preuzeto s: https://hrcak.srce.hr/11031 (Datum pristupa: 04.03.2021.)
Vancouver
Ivaniš T, Živko-Babić J, Lazić B, Pandurić J. Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola. Acta stomatologica Croatica [Internet]. 2000 [pristupljeno 04.03.2021.];34(1):5-10. Dostupno na: https://hrcak.srce.hr/11031
IEEE
T. Ivaniš, J. Živko-Babić, B. Lazić i J. Pandurić, "Dimenzijska stabilnost elastomernih otisnih materijala dezinficiranih u otopini 0,5% klorheksidina i alkohola", Acta stomatologica Croatica, vol.34, br. 1, str. 5-10, 2000. [Online]. Dostupno na: https://hrcak.srce.hr/11031. [Citirano: 04.03.2021.]
Puni tekst: engleski, pdf (59 KB) str. 11-14 preuzimanja: 3.270* citiraj
APA 6th Edition
Ivaniš, T., Živko-Babić, J., Lazić, B. i Pandurić, J. (2000). Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol. Acta stomatologica Croatica, 34 (1), 11-14. Preuzeto s https://hrcak.srce.hr/11031
MLA 8th Edition
Ivaniš, Tomislav, et al. "Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol." Acta stomatologica Croatica, vol. 34, br. 1, 2000, str. 11-14. https://hrcak.srce.hr/11031. Citirano 04.03.2021.
Chicago 17th Edition
Ivaniš, Tomislav, Jasenka Živko-Babić, Biserka Lazić i Josip Pandurić. "Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol." Acta stomatologica Croatica 34, br. 1 (2000): 11-14. https://hrcak.srce.hr/11031
Harvard
Ivaniš, T., et al. (2000). 'Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol', Acta stomatologica Croatica, 34(1), str. 11-14. Preuzeto s: https://hrcak.srce.hr/11031 (Datum pristupa: 04.03.2021.)
Vancouver
Ivaniš T, Živko-Babić J, Lazić B, Pandurić J. Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol. Acta stomatologica Croatica [Internet]. 2000 [pristupljeno 04.03.2021.];34(1):11-14. Dostupno na: https://hrcak.srce.hr/11031
IEEE
T. Ivaniš, J. Živko-Babić, B. Lazić i J. Pandurić, "Dimensional Stability of Elastomeric Impression Materials Disinfected in a Solution of 0.5% Chlorhexidine Gluconate and Alcohol", Acta stomatologica Croatica, vol.34, br. 1, str. 11-14, 2000. [Online]. Dostupno na: https://hrcak.srce.hr/11031. [Citirano: 04.03.2021.]

Sažetak
Dezinfekcija elastomernih materijala za otiske može prouzročiti njihove dimenzijske promjene. Na našoj se klinici kao dezinficijens najčešće upotrebljava 0,5% klorheksidin glukonat.
Svrha rada bila je izmjeriti i usporediti linearne dimenzijske promjene koje nastaju u trima elastomerima nakon uranjanja u spomenuti dezinficijens.
Radni kalup napravljen je prema ADA specifikaciji br.19. Testirani su Panasil (adicijski silikon), Blend-a-scon (kondenzacijski silikon) i Impregum (polieter). Uzorci su izloženi dezinficijensu, vodi i zraku u četiri razdoblja (10 min., 30 min., 60 min. i tijekom 24 sata). Linearne dimenzijske promjene izmjerene su bezkontaktnim digitalnim alatnim mikroskopom.
Rezultati su pokazali najmanje dimenzijske promjene adicijskog silikona s tendencijom širenja. Kondenzacijski silikon skvrčio se unutar tolerantnoga raspona od 0,2 - 0,4%, prema DIN 13913, a polieter je znatno nabubrio.
Može se zaključiti da testirani polieter nije prikladno dezinficirati uranjanjem u klorheksidin glukonat, a druga dva materijala pokazuju klinički prihvatljive linearne dimenzijske promjene unutar 24-satne imerzije.

Ključne riječi
elastomeri; dezinfekcija; klorheksidin glukonat; dimenzijske promjene

Hrčak ID: 11031

URI
https://hrcak.srce.hr/11031

[engleski]

Posjeta: 4.812 *