hrcak mascot   Srce   HID

Izvorni znanstveni članak

Measurement of the Root Canal Length by Endometers ES-02 and ES-03

Silvana Jukić Krmek
Dragana Mihaljević
Paris Simeon
Zoran Karlović

Puni tekst: engleski, pdf (294 KB) str. 19-27 preuzimanja: 882* citiraj
APA 6th Edition
Jukić Krmek, S., Mihaljević, D., Simeon, P. i Karlović, Z. (2006). Measurement of the Root Canal Length by Endometers ES-02 and ES-03. Acta stomatologica Croatica, 40 (1), 19-27. Preuzeto s https://hrcak.srce.hr/11145
MLA 8th Edition
Jukić Krmek, Silvana, et al. "Measurement of the Root Canal Length by Endometers ES-02 and ES-03." Acta stomatologica Croatica, vol. 40, br. 1, 2006, str. 19-27. https://hrcak.srce.hr/11145. Citirano 05.03.2021.
Chicago 17th Edition
Jukić Krmek, Silvana, Dragana Mihaljević, Paris Simeon i Zoran Karlović. "Measurement of the Root Canal Length by Endometers ES-02 and ES-03." Acta stomatologica Croatica 40, br. 1 (2006): 19-27. https://hrcak.srce.hr/11145
Harvard
Jukić Krmek, S., et al. (2006). 'Measurement of the Root Canal Length by Endometers ES-02 and ES-03', Acta stomatologica Croatica, 40(1), str. 19-27. Preuzeto s: https://hrcak.srce.hr/11145 (Datum pristupa: 05.03.2021.)
Vancouver
Jukić Krmek S, Mihaljević D, Simeon P, Karlović Z. Measurement of the Root Canal Length by Endometers ES-02 and ES-03. Acta stomatologica Croatica [Internet]. 2006 [pristupljeno 05.03.2021.];40(1):19-27. Dostupno na: https://hrcak.srce.hr/11145
IEEE
S. Jukić Krmek, D. Mihaljević, P. Simeon i Z. Karlović, "Measurement of the Root Canal Length by Endometers ES-02 and ES-03", Acta stomatologica Croatica, vol.40, br. 1, str. 19-27, 2006. [Online]. Dostupno na: https://hrcak.srce.hr/11145. [Citirano: 05.03.2021.]
Puni tekst: hrvatski, pdf (294 KB) str. 19-27 preuzimanja: 797* citiraj
APA 6th Edition
Jukić Krmek, S., Mihaljević, D., Simeon, P. i Karlović, Z. (2006). Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03. Acta stomatologica Croatica, 40 (1), 19-27. Preuzeto s https://hrcak.srce.hr/11145
MLA 8th Edition
Jukić Krmek, Silvana, et al. "Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03." Acta stomatologica Croatica, vol. 40, br. 1, 2006, str. 19-27. https://hrcak.srce.hr/11145. Citirano 05.03.2021.
Chicago 17th Edition
Jukić Krmek, Silvana, Dragana Mihaljević, Paris Simeon i Zoran Karlović. "Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03." Acta stomatologica Croatica 40, br. 1 (2006): 19-27. https://hrcak.srce.hr/11145
Harvard
Jukić Krmek, S., et al. (2006). 'Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03', Acta stomatologica Croatica, 40(1), str. 19-27. Preuzeto s: https://hrcak.srce.hr/11145 (Datum pristupa: 05.03.2021.)
Vancouver
Jukić Krmek S, Mihaljević D, Simeon P, Karlović Z. Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03. Acta stomatologica Croatica [Internet]. 2006 [pristupljeno 05.03.2021.];40(1):19-27. Dostupno na: https://hrcak.srce.hr/11145
IEEE
S. Jukić Krmek, D. Mihaljević, P. Simeon i Z. Karlović, "Mjerenje radne duljine korijenskog kanala endometrima ES-02 i ES-03", Acta stomatologica Croatica, vol.40, br. 1, str. 19-27, 2006. [Online]. Dostupno na: https://hrcak.srce.hr/11145. [Citirano: 05.03.2021.]

Sažetak
The aim of this study was to compare the accuracy of measurements of endometers ES-02 and ES-03 in dry canals and canals filled with sodium-hypochlorite and ethylenediaminetetraacetic acid (EDTA). For the experiment 31 one-rooted human extracted teeth were used. Working length of the root canal was determined visually using a #15 reamer as a control measurement. After that the teeth were mbedded in vial with freshly mixed alginate and the measurements were made with both devices. Two measurements were made in dry canal and canal filled with sodiumhypochlorite and EDTA for each device. The first value was the working length determined according to the sign -1,0 on the scale and display, respectively, which corresponds to the apical constriction. The second value was measured according to the sign 0,0 which corresponds to the external foramen. Results were analyzed statistically by MANOVA test, and as post-hoc test Student-t test was used. The measurements same as control were in 65% for ES-02 device, and 61%, for ES-03 device at point -1,0 in dry canal, although the difference was not statistically significant. Fluids in root canal statistically significant negatively influence on accuracy of measurements but that significance was 10 times greater at point of measurement -1,0 than at 0,0.

Ključne riječi
root canal preparation; tooth apex; root canal therapy; sodium hypoclorite; chelating agents

Hrčak ID: 11145

URI
https://hrcak.srce.hr/11145

[hrvatski]

Posjeta: 2.097 *