Vedran Mudronja ; Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 1, 10000 Zagreb, Croatia
Gorana Baršić ; Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 1, 10000 Zagreb, Croatia
Biserka Runje   ORCID icon orcid.org/0000-0002-7786-0864 ; Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 1, 10000 Zagreb, Croatia

Puni tekst: engleski, pdf (629 KB) str. 141-145 preuzimanja: 219* citiraj
APA 6th Edition
Mudronja, V., Baršić, G. i Runje, B. (2014). Calibration of the vertical measuring system of stylus instrument Perthometer S8P. Tehnički vjesnik, 21 (1), 141-145. Preuzeto s https://hrcak.srce.hr/116586
MLA 8th Edition
Mudronja, Vedran, et al. "Calibration of the vertical measuring system of stylus instrument Perthometer S8P." Tehnički vjesnik, vol. 21, br. 1, 2014, str. 141-145. https://hrcak.srce.hr/116586. Citirano 26.02.2021.
Chicago 17th Edition
Mudronja, Vedran, Gorana Baršić i Biserka Runje. "Calibration of the vertical measuring system of stylus instrument Perthometer S8P." Tehnički vjesnik 21, br. 1 (2014): 141-145. https://hrcak.srce.hr/116586
Harvard
Mudronja, V., Baršić, G., i Runje, B. (2014). 'Calibration of the vertical measuring system of stylus instrument Perthometer S8P', Tehnički vjesnik, 21(1), str. 141-145. Preuzeto s: https://hrcak.srce.hr/116586 (Datum pristupa: 26.02.2021.)
Vancouver
Mudronja V, Baršić G, Runje B. Calibration of the vertical measuring system of stylus instrument Perthometer S8P. Tehnički vjesnik [Internet]. 2014 [pristupljeno 26.02.2021.];21(1):141-145. Dostupno na: https://hrcak.srce.hr/116586
IEEE
V. Mudronja, G. Baršić i B. Runje, "Calibration of the vertical measuring system of stylus instrument Perthometer S8P", Tehnički vjesnik, vol.21, br. 1, str. 141-145, 2014. [Online]. Dostupno na: https://hrcak.srce.hr/116586. [Citirano: 26.02.2021.]
Puni tekst: hrvatski, pdf (629 KB) str. 141-145 preuzimanja: 603* citiraj
APA 6th Edition
Mudronja, V., Baršić, G. i Runje, B. (2014). Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P. Tehnički vjesnik, 21 (1), 141-145. Preuzeto s https://hrcak.srce.hr/116586
MLA 8th Edition
Mudronja, Vedran, et al. "Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P." Tehnički vjesnik, vol. 21, br. 1, 2014, str. 141-145. https://hrcak.srce.hr/116586. Citirano 26.02.2021.
Chicago 17th Edition
Mudronja, Vedran, Gorana Baršić i Biserka Runje. "Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P." Tehnički vjesnik 21, br. 1 (2014): 141-145. https://hrcak.srce.hr/116586
Harvard
Mudronja, V., Baršić, G., i Runje, B. (2014). 'Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P', Tehnički vjesnik, 21(1), str. 141-145. Preuzeto s: https://hrcak.srce.hr/116586 (Datum pristupa: 26.02.2021.)
Vancouver
Mudronja V, Baršić G, Runje B. Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P. Tehnički vjesnik [Internet]. 2014 [pristupljeno 26.02.2021.];21(1):141-145. Dostupno na: https://hrcak.srce.hr/116586
IEEE
V. Mudronja, G. Baršić i B. Runje, "Umjeravanje vertikalne komponente elektroničko-mehaničkog uređaja s ticalom Perthometer S8P", Tehnički vjesnik, vol.21, br. 1, str. 141-145, 2014. [Online]. Dostupno na: https://hrcak.srce.hr/116586. [Citirano: 26.02.2021.]

Sažetak
Measurement result without defined metrological traceability does not represent valid metrological information. National laboratory for length (HMI/FSB-LPMD), as constitutive part of Croatian Metrology Institute (HMI), has a responsibility to assure traceability using national and first line standards for length, roughness and angle. In HMI/FSB-LPMD traceability for roughness parameters is assured using calibrated National roughness standards. In this paper calibration of the vertical measuring system of stylus instrument Perthometer S8P using roughness standard is presented. Calibration has been performed according to the recommendations from DKD Guideline 4-2. Based on the model shown in Directive DKD R 4-2, sheet 1, Annex A measurement uncertainty of a roughness parameter Rz determined using Perthometer S8P has been evaluated.

Ključne riječi
calibration; metrological traceability; roughness standard; stylus instrument