XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing

Krzysztof Rokosz ; Division of Surface Electrochemistry and Technology, Koszalin University of Technology, Racławicka 15-17, 75-620 Koszalin, Poland
Tadeusz Hryniewicz ; Division of Surface Electrochemistry and Technology, Koszalin University of Technology, Racławicka 15-17, 75-620 Koszalin, Poland
Ryszard Rokicki ; ELECTROBRIGHT, 142 W. Main St., Macungie, PA 18062, USA

Puni tekst: engleski, pdf (1 MB) str. 799-805 preuzimanja: 249* citiraj
APA 6th Edition
Rokosz, K., Hryniewicz, T. i Rokicki, R. (2014). XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing. Tehnički vjesnik, 21 (4), 799-805. Preuzeto s https://hrcak.srce.hr/126075
MLA 8th Edition
Rokosz, Krzysztof, et al. "XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing." Tehnički vjesnik, vol. 21, br. 4, 2014, str. 799-805. https://hrcak.srce.hr/126075. Citirano 03.03.2021.
Chicago 17th Edition
Rokosz, Krzysztof, Tadeusz Hryniewicz i Ryszard Rokicki. "XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing." Tehnički vjesnik 21, br. 4 (2014): 799-805. https://hrcak.srce.hr/126075
Harvard
Rokosz, K., Hryniewicz, T., i Rokicki, R. (2014). 'XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing', Tehnički vjesnik, 21(4), str. 799-805. Preuzeto s: https://hrcak.srce.hr/126075 (Datum pristupa: 03.03.2021.)
Vancouver
Rokosz K, Hryniewicz T, Rokicki R. XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing. Tehnički vjesnik [Internet]. 2014 [pristupljeno 03.03.2021.];21(4):799-805. Dostupno na: https://hrcak.srce.hr/126075
IEEE
K. Rokosz, T. Hryniewicz i R. Rokicki, "XPS measurements of AISI 316LVM SS biomaterial tubes after magnetoelectropolishing", Tehnički vjesnik, vol.21, br. 4, str. 799-805, 2014. [Online]. Dostupno na: https://hrcak.srce.hr/126075. [Citirano: 03.03.2021.]
Puni tekst: hrvatski, pdf (1 MB) str. 799-805 preuzimanja: 612* citiraj
APA 6th Edition
Rokosz, K., Hryniewicz, T. i Rokicki, R. (2014). XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja. Tehnički vjesnik, 21 (4), 799-805. Preuzeto s https://hrcak.srce.hr/126075
MLA 8th Edition
Rokosz, Krzysztof, et al. "XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja." Tehnički vjesnik, vol. 21, br. 4, 2014, str. 799-805. https://hrcak.srce.hr/126075. Citirano 03.03.2021.
Chicago 17th Edition
Rokosz, Krzysztof, Tadeusz Hryniewicz i Ryszard Rokicki. "XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja." Tehnički vjesnik 21, br. 4 (2014): 799-805. https://hrcak.srce.hr/126075
Harvard
Rokosz, K., Hryniewicz, T., i Rokicki, R. (2014). 'XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja', Tehnički vjesnik, 21(4), str. 799-805. Preuzeto s: https://hrcak.srce.hr/126075 (Datum pristupa: 03.03.2021.)
Vancouver
Rokosz K, Hryniewicz T, Rokicki R. XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja. Tehnički vjesnik [Internet]. 2014 [pristupljeno 03.03.2021.];21(4):799-805. Dostupno na: https://hrcak.srce.hr/126075
IEEE
K. Rokosz, T. Hryniewicz i R. Rokicki, "XPS mjerenja cijevi od biomaterijala AISI 316LVM SS nakon magnetoelektropoliranja", Tehnički vjesnik, vol.21, br. 4, str. 799-805, 2014. [Online]. Dostupno na: https://hrcak.srce.hr/126075. [Citirano: 03.03.2021.]

Sažetak
XPS (X-ray Photoelectron Spectroscopy) measurements were performed on AISI 316LVM stainless steel tubes of biomaterial samples, serving for stents, after a standard electropolishing (EP), and magnetoelectropolishing (MEP). After electropolishing operations, the samples were kept in a closed foil pack for about four years. The results of XPS analysis indicate a significant difference in the measurement and calculation values, dependent on surface treatment method: EP and/or MEP. The steel surface film composition and PREN (pitting resistance equivalent number) were calculated. The highest numbers of these values were obtained on samples after MEP where both chromium compounds (Cr 2p) and molybdenum (Mo 3d) increased over three times against these values after EP treatment. The calculated PRENMEP (Fe, Cr, Mo, Mn, Ni, P, S, O) = 16,37, with PRENMEP (Fe, Cr, Mo, Mn, Ni, P, S) = 36,89, versus PRENEP (Fe, Cr, Mo, Mn, Ni, P, S, O) = 3,12, with PRENEP (Fe, Cr, Mo, Mn, Ni, P, S) = 8,53. The results obtained point to an advantageous and unusual effect of the magnetic field action during MEP.

Ključne riječi
magnetoelectropolishing (MEP); PREN (pitting resistance equivalent number); 316LVM SS tube biomaterial; XPS results comparison

Hrčak ID: 126075