Skoči na glavni sadržaj

Prethodno priopćenje

Factors of estimating flatness error as a surface requirement of exploitation

M. Hadžistević ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
B. Štrbac ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
V. Spasić Jokić ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
M. Delić ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
M. Sekulić ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia
J. Hodolič ; Faculty of Technical Sciences, University of Novi Sad, Novi Sad, Serbia


Puni tekst: engleski pdf 267 Kb

str. 239-242

preuzimanja: 1.335

citiraj


Sažetak

This study considers the impact of surface quality (surface roughness) on estimating flatness error when measurements are performed using coordinate measuring machine (CMM). Flatness error is estimated using various association methods and various sample sizes, while the distribution of sample points is done randomly on a flatness feature using the random number generator in Matlab. ANOVA is used for determining the significance of differences between the observed groups. It has been determined that the estimate of flatness error is affected by the processing method, the number of sample points and associative method used, but not by surface roughness.

Ključne riječi

roughness; surface; flatness; error, CMM

Hrčak ID:

126743

URI

https://hrcak.srce.hr/126743

Datum izdavanja:

1.1.2015.

Posjeta: 1.857 *