Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.1112.2014

Experimental studies on corrugated steel-concrete composite slab

Hajir Satih Abbas
Sohaimi Abu Bakar
Mohammad Ahmadi
Zaiton Haron


Puni tekst: hrvatski pdf 707 Kb

str. 225-233

preuzimanja: 2.208

citiraj

Puni tekst: engleski pdf 696 Kb

str. 225-233

preuzimanja: 1.495

citiraj


Sažetak

Composite deck slabs are composed of normal concrete and corrugated steel sheet. The strength of composite slabs is governed by shear interaction between the concrete and the steel deck. This interaction depends on several factors and no relationship criteria can be found for interaction property from analytical basis. Therefore, the analysis and design methods are used by means of empirical analysis. In this paper, the experimental work is conducted to develop a new scale test method by using two lines of shear connectors welded onto the corrugated plate and lateral beam, in order to increase the shear bond resistance of a composite slab.

Ključne riječi

composite slab; shear connector; corrugated steel plate; longitudinal failure and experimental test

Hrčak ID:

137752

URI

https://hrcak.srce.hr/137752

Datum izdavanja:

14.4.2015.

Podaci na drugim jezicima: hrvatski

Posjeta: 4.532 *