Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5772/53926

Preparation and Characterization of Fluorescent CdS Quantum Dots used for the Direct Detection of GST Fusion Proteins

J. J. Beato-López ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain
C. Fernández-Ponce ; Departamento de Biomedicina, Biotecnologia y Salud Publica, Universidad de Cádiz, Cádiz, Spain
E. Blanco ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain
C. Barrera-Solano ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain
M. Ramirez-del-Solar ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain
M. Dominguez ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain
F. García-Cozar ; Departamento de Biomedicina, Biotecnologia y Salud Publica, Universidad de Cádiz, Cádiz, Spain
R. Litrán ; Departamento de Fisica de la Materia Condensada, Universidad de Cádiz, Cádiz, Spain


Puni tekst: engleski pdf 1.752 Kb

str. 2-10

preuzimanja: 1.898

citiraj


Sažetak

Advances in the life sciences are now closely linked to the availability of new experimental tools that allow for the manipulation of biomolecules and the study of biological processes at the molecular level. In this context, we have optimized a synthesis process to obtain glutathione‐capped fluorescent CdS nanoparticles to specifically detect Glutathione S‐Transferase (GST) ‐tagged proteins. Using our method, based on five different heating steps, brightly fluorescent and biocompatible CdS quantum dots of different sizes can be obtained. QD optical behaviour has been evaluated studying both absorbance and fluorescence. For all the samples, the excitonic absorption onset clearly shows a blue shift at 512nm in comparison with that of bulk CdS, due to the quantum confinement effect. At increased average sizes of the nanocrystal, the emission fluorescent band shows a red shift, from 440nm to 540nm. Among different QD solutions, we demonstrate an expansion of the emission range up to ~100 nm, thus improving their features as biomarkers. Moreover we show that optimized glutathione-capped quantum dots can directly bind GST blotted onto polyvinylidene difluoride (PVDF) membranes, and thus are suitable for the direct detection of GST fusion proteins.

Ključne riječi

quantum dots; fluorescence; glutathione; glutathione S-transferase fusion protein

Hrčak ID:

142871

URI

https://hrcak.srce.hr/142871

Datum izdavanja:

1.1.2012.

Posjeta: 2.326 *