hrcak mascot   Srce   HID

Izvorni znanstveni članak

Application of Fourier Transform Profilometry in Pulmonary Function Testing

M. Leonardi ; Jožef Stefan Institute, Ljubljana, Slovenija
M. Fležar ; UKC, Ljubljana, Slovenija
A. Urbanč ; Jožef Stefan Institute, Ljubljana, Slovenija
J. Lenarčič ; Jožef Stefan Institute, Ljubljana, Slovenija

Puni tekst: engleski, pdf (4 MB) str. 223-231 preuzimanja: 57* citiraj
APA 6th Edition
Leonardi, M., Fležar, M., Urbanč, A. i Lenarčič, J. (1994). Application of Fourier Transform Profilometry in Pulmonary Function Testing. Journal of computing and information technology, 2 (3), 223-231. Preuzeto s https://hrcak.srce.hr/150461
MLA 8th Edition
Leonardi, M., et al. "Application of Fourier Transform Profilometry in Pulmonary Function Testing." Journal of computing and information technology, vol. 2, br. 3, 1994, str. 223-231. https://hrcak.srce.hr/150461. Citirano 19.02.2020.
Chicago 17th Edition
Leonardi, M., M. Fležar, A. Urbanč i J. Lenarčič. "Application of Fourier Transform Profilometry in Pulmonary Function Testing." Journal of computing and information technology 2, br. 3 (1994): 223-231. https://hrcak.srce.hr/150461
Harvard
Leonardi, M., et al. (1994). 'Application of Fourier Transform Profilometry in Pulmonary Function Testing', Journal of computing and information technology, 2(3), str. 223-231. Preuzeto s: https://hrcak.srce.hr/150461 (Datum pristupa: 19.02.2020.)
Vancouver
Leonardi M, Fležar M, Urbanč A, Lenarčič J. Application of Fourier Transform Profilometry in Pulmonary Function Testing. Journal of computing and information technology [Internet]. 1994 [pristupljeno 19.02.2020.];2(3):223-231. Dostupno na: https://hrcak.srce.hr/150461
IEEE
M. Leonardi, M. Fležar, A. Urbanč i J. Lenarčič, "Application of Fourier Transform Profilometry in Pulmonary Function Testing", Journal of computing and information technology, vol.2, br. 3, str. 223-231, 1994. [Online]. Dostupno na: https://hrcak.srce.hr/150461. [Citirano: 19.02.2020.]

Sažetak
This paper compares Fourier Transform Profilometry, a computer based technique for automatic 3-D measurement, with conventional Moife techniques. In Moire contouring techniques two gratings are used to generate Moire fringes. In contrast to that in FTP a grating pattern projected onto the object surface is Fourier transformed and processed. Results are analysed and some alternative tests are presented. In addition to that an application in medicine is proposed for pulmonary function testing. Several measurements of lung relaxation pressure by observi ng the depression of skin between ribs have been performed.

Ključne riječi
Fourier Transform Profilometry; Moire contouring techniques

Hrčak ID: 150461

URI
https://hrcak.srce.hr/150461

Posjeta: 94 *