Skoči na glavni sadržaj

Pregledni rad

https://doi.org/10.14256/JCE.1329.2015

Load-bearing capacity of fire exposed composite columns

Milivoje Milanović
Meri Cvetkovska
Petar Knežević


Puni tekst: hrvatski pdf 750 Kb

str. 1187-1197

preuzimanja: 567

citiraj

Puni tekst: engleski pdf 740 Kb

str. 1187-1197

preuzimanja: 854

citiraj


Sažetak

The cross-section load-bearing capacity of three types of fire exposed steel-concrete composite columns is analysed in this paper, and the results are compared with the load-bearing capacity of a reference reinforced-concrete column. Mechanical properties of constitutive materials are reduced considerably by high temperatures caused by fire action, which results in a reduced load bearing capacity of columns with regard to the longitudinal force and biaxial bending moment. The reduced load bearing capacity of analysed columns subjected to elevated temperatures is expressed through changes in the M-N interaction curves.

Ključne riječi

composite column; temperature; heat transfer; fire resistance

Hrčak ID:

151154

URI

https://hrcak.srce.hr/151154

Datum izdavanja:

14.1.2016.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.095 *