hrcak mascot   Srce   HID

Izvorni znanstveni članak

Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks

Želimir Korać
Dubravko Kelenc
Danko Mikulić
Janko Hančević

Puni tekst: engleski, pdf (70 KB) str. 211-214 preuzimanja: 557* citiraj
APA 6th Edition
Korać, Ž., Kelenc, D., Mikulić, D. i Hančević, J. (2000). Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks. Acta clinica Croatica, 39 (4), 211-214. Preuzeto s https://hrcak.srce.hr/14974
MLA 8th Edition
Korać, Želimir, et al. "Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks." Acta clinica Croatica, vol. 39, br. 4, 2000, str. 211-214. https://hrcak.srce.hr/14974. Citirano 15.11.2019.
Chicago 17th Edition
Korać, Želimir, Dubravko Kelenc, Danko Mikulić i Janko Hančević. "Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks." Acta clinica Croatica 39, br. 4 (2000): 211-214. https://hrcak.srce.hr/14974
Harvard
Korać, Ž., et al. (2000). 'Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks', Acta clinica Croatica, 39(4), str. 211-214. Preuzeto s: https://hrcak.srce.hr/14974 (Datum pristupa: 15.11.2019.)
Vancouver
Korać Ž, Kelenc D, Mikulić D, Hančević J. Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks. Acta clinica Croatica [Internet]. 2000 [pristupljeno 15.11.2019.];39(4):211-214. Dostupno na: https://hrcak.srce.hr/14974
IEEE
Ž. Korać, D. Kelenc, D. Mikulić i J. Hančević, "Analysis of Temporary Cavity Produced by High Velocity Missile in Gelatin Blocks", Acta clinica Croatica, vol.39, br. 4, str. 211-214, 2000. [Online]. Dostupno na: https://hrcak.srce.hr/14974. [Citirano: 15.11.2019.]

Sažetak
The effects of high velocity missiles (a Russian AK-74 assault rifle, 5.45 mm) in a tissue simulant • gelatin block were analyzed. The characteristics of temporary cavity were studied by the analysis of calibrated images of the missile path. The missile path through the block was visualized using a TV camera with an ultra-speed shutter. TV picture was calibrated before the shooting. Cross-section of the temporary cavity was measured as a function of distance from the missile entry point. The missile track was found to be unpredictable, with deviations to the left, right, up and down. The missiles were unstable regarding precession. Study results showed the temporary cavity to be relatively narrow and regular in the first 10 cm from the missile entry point, becoming much larger and more irregular along the missile track. The largest tissue disruption was found between 150 and 200 mm of the missile path. The missiles were not found to deform or fragment. On the basis of the images obtained, it would be possible to calculate the volume of temporary cavity, which is one of the most significant indicators of tissue disrupting potential of particular missile types.

Ključne riječi
Wounds, gunshot; Gelatin; Models; Military medicine; Forensic medicine

Hrčak ID: 14974

URI
https://hrcak.srce.hr/14974

[hrvatski]

Posjeta: 901 *