hrcak mascot   Srce   HID

Stručni rad

DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH

Zbynĕk Zelený   ORCID icon orcid.org/0000-0002-7495-8225 ; Czech Technical University in Prague, UCEEB, Bustehrad, Czech Republic
Jan Hrdlička ; Czech Technical University in Prague, UCEEB, Bustehrad, Czech Republic

Puni tekst: engleski, pdf (913 KB) str. 89-96 preuzimanja: 491* citiraj
APA 6th Edition
Zelený, Z. i Hrdlička, J. (2016). DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH. The holistic approach to environment, 6 (2), 89-96. Preuzeto s https://hrcak.srce.hr/154909
MLA 8th Edition
Zelený, Zbynĕk i Jan Hrdlička. "DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH." The holistic approach to environment, vol. 6, br. 2, 2016, str. 89-96. https://hrcak.srce.hr/154909. Citirano 11.12.2019.
Chicago 17th Edition
Zelený, Zbynĕk i Jan Hrdlička. "DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH." The holistic approach to environment 6, br. 2 (2016): 89-96. https://hrcak.srce.hr/154909
Harvard
Zelený, Z., i Hrdlička, J. (2016). 'DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH', The holistic approach to environment, 6(2), str. 89-96. Preuzeto s: https://hrcak.srce.hr/154909 (Datum pristupa: 11.12.2019.)
Vancouver
Zelený Z, Hrdlička J. DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH. The holistic approach to environment [Internet]. 2016 [pristupljeno 11.12.2019.];6(2):89-96. Dostupno na: https://hrcak.srce.hr/154909
IEEE
Z. Zelený i J. Hrdlička, "DOWNSCALE APPLICATION OF BOILER THERMAL CALCULATION APPROACH", The holistic approach to environment, vol.6, br. 2, str. 89-96, 2016. [Online]. Dostupno na: https://hrcak.srce.hr/154909. [Citirano: 11.12.2019.]

Sažetak
Commonly used thermal calculation methods are intended primarily for large scale boilers. Hot water small scale boilers, which are commonly used for home heating have many specifics, that distinguish them from large scale boilers especially steam boilers. This paper is focused on application of thermal calculation procedure that is designed for large scale boilers, on a small scale boiler for biomass combustion of load capacity 25 kW. Special issue solved here is influence of formation of deposits on heat exchanging surfaces on efficiency of heat transfer and on overall boiler efficiency. In the paper are presented results of mathematical model created for this purpose and its verification by experimental measurement in this specific boiler.

Ključne riječi
small scale biomass boiler; thermal calculation methods; heat transfer; heat transfer surface deposits