Biodegradation and mechanical behaviour of sintered compacts of Co-Cr alloy powder doped with ZrO2 used in dentistry

Diana-Irinel Băilă orcid id orcid.org/0000-0003-4091-6358 ; University POLITEHNICA of Bucharest, 313, Spl. Independentei, district 6, 060042, Bucharest, Romania
Oana-Cătălina Mocioiu ; "Ilie Murgulescu" Institute of Physical Chemistry of Romanian Academy, 202, Spl. Independentei, district 6, 060021, Bucharest, Romania
Roxana Truşcă ; METAV CD, 31, Rosetti, district 2, 20011, Bucharest, Romania
Adrian Surdu ; University POLITEHNICA of Bucharest, 313, Spl. Independentei, district 6, 060042, Bucharest, Romania
Cătălin Zaharia ; University POLITEHNICA of Bucharest, 313, Spl. Independentei, district 6, 060042, Bucharest, Romania
Mihaela Bunea ; University POLITEHNICA of Bucharest, 313, Spl. Independentei, district 6, 060042, Bucharest, Romania


Puni tekst: hrvatski pdf 3.390 Kb

str. 1047-1057

preuzimanja: 593

citiraj

Puni tekst: engleski pdf 3.390 Kb

str. 1047-1057

preuzimanja: 273

citiraj


Sažetak

Direct Metal Laser Sintering process is modern technology and is used in different industries, inclusive in medicine industry. The purpose of this study was to obtain sintered compacts of Co-Cr powder doped with ZrO2 in order to improve the bioactivity of the implants and the behavior in vitro after immersion in simulated biological fluid (SBF) for 21 days. Co-Cr powders (ST2724G) were used to realize one reference sample of Co-Cr and 4 compacts of Co-Cr doped with ZrO2 in the following percents: a) 5 % ZrO2, b) 10 % ZrO2, c) 15 % ZrO2, d) 20 % ZrO2. The morphology and structure of all compacts were determined using scanning electron microscope (SEM), EDS (quantitative and qualitative) and X-ray diffraction analysis (XRD). The microstructures differ in function of concentrations. XRD presents qualitative analysis of Co-Cr probes doped with zirconia and EDS analysis presents qualitative and quantitative analysis of composites compacts, before and after immersion in SBF for 21 days. After immersion in SBF, it can be noticed that the probes of Co-Cr doped with zirconia demonstrate good corrosion resistance and that for the probe Co-Cr doped with 20 % zirconia mechanical resistance is low. In this study the mechanical behavior of Co-Cr powder manufacturing by Direct Metal Laser Sintering (DMLS) process was determined. The sintering machine Phenix Systems type PXS & PXM Dental uses the Co-Cr powder (ST2724G) and for 3D printing use "stl" file. The mechanical tests (traction and compression) was realized with an INSTRON 8810 machine.

Ključne riječi

biodegradation; Co-Cr sintered compact; dental implant; in vitro test; mechanical behaviour; SEM analysis; ZrO2; XRD analysis