Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu
Zoran Mitrović
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Dušan Čomić
; EPS Elektrovojvodina, Bulevar oslobođenja 100, 21000 Novi Sad, Serbia
Slobodan Milovančev
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Dragan Pejić
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
APA 6th Edition Mitrović, Z., Čomić, D., Milovančev, S. i Pejić, D. (2016). Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu. Tehnički vjesnik, 23 (5), 1245-1250. https://doi.org/10.17559/TV-20150318102342
MLA 8th Edition Mitrović, Zoran, et al. "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1245-1250. https://doi.org/10.17559/TV-20150318102342. Citirano 27.02.2021.
Chicago 17th Edition Mitrović, Zoran, Dušan Čomić, Slobodan Milovančev i Dragan Pejić. "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu." Tehnički vjesnik 23, br. 5 (2016): 1245-1250. https://doi.org/10.17559/TV-20150318102342
Harvard Mitrović, Z., et al. (2016). 'Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu', Tehnički vjesnik, 23(5), str. 1245-1250. https://doi.org/10.17559/TV-20150318102342
Vancouver Mitrović Z, Čomić D, Milovančev S, Pejić D. Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu. Tehnički vjesnik [Internet]. 2016 [pristupljeno 27.02.2021.];23(5):1245-1250. https://doi.org/10.17559/TV-20150318102342
IEEE Z. Mitrović, D. Čomić, S. Milovančev i D. Pejić, "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu", Tehnički vjesnik, vol.23, br. 5, str. 1245-1250, 2016. [Online]. https://doi.org/10.17559/TV-20150318102342
APA 6th Edition Mitrović, Z., Čomić, D., Milovančev, S. i Pejić, D. (2016). High voltage coreless transformer for power quality measurement at medium voltage level. Tehnički vjesnik, 23 (5), 1245-1250. https://doi.org/10.17559/TV-20150318102342
MLA 8th Edition Mitrović, Zoran, et al. "High voltage coreless transformer for power quality measurement at medium voltage level." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1245-1250. https://doi.org/10.17559/TV-20150318102342. Citirano 27.02.2021.
Chicago 17th Edition Mitrović, Zoran, Dušan Čomić, Slobodan Milovančev i Dragan Pejić. "High voltage coreless transformer for power quality measurement at medium voltage level." Tehnički vjesnik 23, br. 5 (2016): 1245-1250. https://doi.org/10.17559/TV-20150318102342
Harvard Mitrović, Z., et al. (2016). 'High voltage coreless transformer for power quality measurement at medium voltage level', Tehnički vjesnik, 23(5), str. 1245-1250. https://doi.org/10.17559/TV-20150318102342
Vancouver Mitrović Z, Čomić D, Milovančev S, Pejić D. High voltage coreless transformer for power quality measurement at medium voltage level. Tehnički vjesnik [Internet]. 2016 [pristupljeno 27.02.2021.];23(5):1245-1250. https://doi.org/10.17559/TV-20150318102342
IEEE Z. Mitrović, D. Čomić, S. Milovančev i D. Pejić, "High voltage coreless transformer for power quality measurement at medium voltage level", Tehnički vjesnik, vol.23, br. 5, str. 1245-1250, 2016. [Online]. https://doi.org/10.17559/TV-20150318102342
Sažetak Mjerenje harmonika u elektrodistributivnoj mreži predstavlja važan dio mjerenja kvalitete električne energije. Suvremeni visokonaponski transformatori sa željeznom jezgrom nisu linearni i ne mogu se lako koristiti za precizno mjerenje izobličenih signala u širokom frekvencijskom opsegu. U ovom članku dani su detalji konstrukcije novog naponskog transformatora bez jezgre za mjerenje kvalitete električne energije. Kao potvrda koncepta izrađena su dva transformatora, s i bez oklopa. Prikazani su rezultati mjerenja parametara transformatora, rezultati simulacije rada transformatora i rezultati mjerenja linearnosti transformatora. Ovi rezultati pokazuju da se predloženi transformator može koristiti za mjerenje kvalitete električne energije na niskim i srednjim naponskim razinama (do 35 kV) s harmonijskim sadržajem do 50-tog reda.