hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20150118204850

Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava

Vedran Kirincic ; University of Rijeka, Faculty of Engineering, Department of Electric Power Systems, Vukovarska 58, 51000 Rijeka, Croatia
Srdjan Skok ; University of Rijeka, Faculty of Engineering, Department of Electric Power Systems, Vukovarska 58, 51000 Rijeka, Croatia
Dubravko Frankovic ; University of Rijeka, Faculty of Engineering, Department of Electric Power Systems, Vukovarska 58, 51000 Rijeka, Croatia

Puni tekst: hrvatski, pdf (451 KB) str. 1457-1462 preuzimanja: 208* citiraj
APA 6th Edition
Kirincic, V., Skok, S. i Frankovic, D. (2016). Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava. Tehnički vjesnik, 23 (5), 1457-1462. https://doi.org/10.17559/TV-20150118204850
MLA 8th Edition
Kirincic, Vedran, et al. "Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1457-1462. https://doi.org/10.17559/TV-20150118204850. Citirano 02.03.2021.
Chicago 17th Edition
Kirincic, Vedran, Srdjan Skok i Dubravko Frankovic. "Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava." Tehnički vjesnik 23, br. 5 (2016): 1457-1462. https://doi.org/10.17559/TV-20150118204850
Harvard
Kirincic, V., Skok, S., i Frankovic, D. (2016). 'Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava', Tehnički vjesnik, 23(5), str. 1457-1462. https://doi.org/10.17559/TV-20150118204850
Vancouver
Kirincic V, Skok S, Frankovic D. Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava. Tehnički vjesnik [Internet]. 2016 [pristupljeno 02.03.2021.];23(5):1457-1462. https://doi.org/10.17559/TV-20150118204850
IEEE
V. Kirincic, S. Skok i D. Frankovic, "Neinvazivna primjena sinkroniziranih mjerenja fazora u estimaciji stanja elektroenergetskog sustava", Tehnički vjesnik, vol.23, br. 5, str. 1457-1462, 2016. [Online]. https://doi.org/10.17559/TV-20150118204850
Puni tekst: engleski, pdf (451 KB) str. 1457-1462 preuzimanja: 168* citiraj
APA 6th Edition
Kirincic, V., Skok, S. i Frankovic, D. (2016). A noninvasive inclusion of synchrophasors in the power system state estimation. Tehnički vjesnik, 23 (5), 1457-1462. https://doi.org/10.17559/TV-20150118204850
MLA 8th Edition
Kirincic, Vedran, et al. "A noninvasive inclusion of synchrophasors in the power system state estimation." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1457-1462. https://doi.org/10.17559/TV-20150118204850. Citirano 02.03.2021.
Chicago 17th Edition
Kirincic, Vedran, Srdjan Skok i Dubravko Frankovic. "A noninvasive inclusion of synchrophasors in the power system state estimation." Tehnički vjesnik 23, br. 5 (2016): 1457-1462. https://doi.org/10.17559/TV-20150118204850
Harvard
Kirincic, V., Skok, S., i Frankovic, D. (2016). 'A noninvasive inclusion of synchrophasors in the power system state estimation', Tehnički vjesnik, 23(5), str. 1457-1462. https://doi.org/10.17559/TV-20150118204850
Vancouver
Kirincic V, Skok S, Frankovic D. A noninvasive inclusion of synchrophasors in the power system state estimation. Tehnički vjesnik [Internet]. 2016 [pristupljeno 02.03.2021.];23(5):1457-1462. https://doi.org/10.17559/TV-20150118204850
IEEE
V. Kirincic, S. Skok i D. Frankovic, "A noninvasive inclusion of synchrophasors in the power system state estimation", Tehnički vjesnik, vol.23, br. 5, str. 1457-1462, 2016. [Online]. https://doi.org/10.17559/TV-20150118204850

Sažetak
Rad istražuje primjenu sinkroniziranih mjerenja fazora, dostupnih iz jedinica za sinkronizirano mjerenja fazora (PMU), u estimaciji stanja elektroenergetskog sustava. Kako bi se izbjegla promjena vrste mjerenja koja ulaze u klasičan estimator stanja korišten u centru vođenja, predloženi model koristi fazore napona i struje za izračun pseudo mjerenja poput pseudo-napona, tokova snage i injekcija snage. Izračunata se pseudo-mjerenja zatim zajedno s amplitudama fazora napona te konvencionalnim mjerenjima primjenjuju u iterativnoj proceduri. Kao test sustavi korišteni su IEEE test sustavi s 14, 30, 57 i 118 čvorišta, kao i matematički model hrvatskog prijenosnog elektroenergetskog sustava. Rezultati dobiveni simulacijom su uspoređeni s rezultatima klasičnog estimatora stanja, koji koristi samo konvencionalna mjerenja. U radu je istražen utjecaj kuta fazora napona na performanse estimatora stanja.

Ključne riječi
estimacija stanja elektroenergetskog sustava; hibridni estimator stanja; jedinica za sinkronizirano mjerenje fazora; tehnologija sinkroniziranih mjerenja fazora

Hrčak ID: 167509

URI
https://hrcak.srce.hr/167509

[engleski]

Posjeta: 658 *