hrcak mascot   Srce   HID

Preliminary communication
https://doi.org/10.21278/brod68204

THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION

Vedran Mrzljak   ORCID icon orcid.org/0000-0003-0323-2600 ; Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia
Igor Poljak   ORCID icon orcid.org/0000-0001-8749-4223 ; Rožići 4/3, 51221 Kostrena, Croatia
Vedran Medica-Viola ; Faculty of Engineering, University of Rijeka, Vukovarska 58, 51000 Rijeka, Croatia

Fulltext: english, pdf (1 MB) pages 45-61 downloads: 1.500* cite
APA 6th Edition
Mrzljak, V., Poljak, I. & Medica-Viola, V. (2017). THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION. Brodogradnja, 68 (2), 45-61. https://doi.org/10.21278/brod68204
MLA 8th Edition
Mrzljak, Vedran, et al. "THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION." Brodogradnja, vol. 68, no. 2, 2017, pp. 45-61. https://doi.org/10.21278/brod68204. Accessed 5 Aug. 2020.
Chicago 17th Edition
Mrzljak, Vedran, Igor Poljak and Vedran Medica-Viola. "THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION." Brodogradnja 68, no. 2 (2017): 45-61. https://doi.org/10.21278/brod68204
Harvard
Mrzljak, V., Poljak, I., and Medica-Viola, V. (2017). 'THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION', Brodogradnja, 68(2), pp. 45-61. https://doi.org/10.21278/brod68204
Vancouver
Mrzljak V, Poljak I, Medica-Viola V. THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION. Brodogradnja [Internet]. 2017 [cited 2020 August 05];68(2):45-61. https://doi.org/10.21278/brod68204
IEEE
V. Mrzljak, I. Poljak and V. Medica-Viola, "THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION", Brodogradnja, vol.68, no. 2, pp. 45-61, 2017. [Online]. https://doi.org/10.21278/brod68204

Abstracts
Nowadays diesel engines prevail as ship propulsion. However, steam propulsion is still primary drive for LNG carriers. In the presented paper high-pressure feed water heater was analyzed, as one of the essential components in LNG carrier steam propulsion system. Measurements of all operating parameters (fluid streams) at the analyzed heat exchanger inlets and outlets were performed. Change of the operating parameters was measured at different steam system loads, not at full load as usual. Through these measurements was enabled the insight into the behaviour of the heat exchanger operating parameters during the whole exploitation. The numerical analysis was performed, based on the measured data. The changes in energy and exergy efficiency of the heat exchanger were analyzed. Energetic and exergetic power inputs and outputs were also calculated, which enabled an insight into the change of energetic and exergetic power losses of the heat exchanger at different steam system loads. Change in energetic and exergetic power losses and operating parameters, which have the strongest influence on the high-pressure feed water heater losses, were described. Analyzed heat exchanger was compared with similar heat exchangers in the base loaded conventional steam power plants. From the conducted analysis, it is concluded that the adjustment and control modes of these high-pressure heat exchangers are equal, regardless of whether they were mounted in the base loaded conventional steam power plants or marine steam systems, while their operating parameters and behaviour patterns differ greatly.

Keywords
High-pressure feed water heater; Energy efficiency; Energetic power loss; Exergy efficiency; Exergetic power loss