hrcak mascot   Srce   HID

Prethodno priopćenje

An application for chemical assessment of water intended for human consumption and irrigation

Željko Duić   ORCID icon orcid.org/0000-0002-5077-5985 ; Faculty of Mining, Geology and Petroleum Engineering, University of Zagreb, Zagreb, Croatia
Daniel Jakobović ; HIS, d.o.o., Donja Višnjica, Croatia
Ivan Posavčević ; Ericsson Nikola Tesla, Zagreb, Croatia

Puni tekst: hrvatski, pdf (489 KB) str. 93-97 preuzimanja: 110* citiraj
APA 6th Edition
Duić, Ž., Jakobović, D. i Posavčević, I. (2017). Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje. Hrvatske vode, 25 (100), 93-97. Preuzeto s https://hrcak.srce.hr/183728
MLA 8th Edition
Duić, Željko, et al. "Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje." Hrvatske vode, vol. 25, br. 100, 2017, str. 93-97. https://hrcak.srce.hr/183728. Citirano 15.12.2019.
Chicago 17th Edition
Duić, Željko, Daniel Jakobović i Ivan Posavčević. "Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje." Hrvatske vode 25, br. 100 (2017): 93-97. https://hrcak.srce.hr/183728
Harvard
Duić, Ž., Jakobović, D., i Posavčević, I. (2017). 'Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje', Hrvatske vode, 25(100), str. 93-97. Preuzeto s: https://hrcak.srce.hr/183728 (Datum pristupa: 15.12.2019.)
Vancouver
Duić Ž, Jakobović D, Posavčević I. Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje. Hrvatske vode [Internet]. 2017 [pristupljeno 15.12.2019.];25(100):93-97. Dostupno na: https://hrcak.srce.hr/183728
IEEE
Ž. Duić, D. Jakobović i I. Posavčević, "Aplikacija za ocjenu kemizma vode za ljudsku potrošnju i navodnjavanje", Hrvatske vode, vol.25, br. 100, str. 93-97, 2017. [Online]. Dostupno na: https://hrcak.srce.hr/183728. [Citirano: 15.12.2019.]

Sažetak
The objective of this paper was the development of an application for presenting chemical analyses of water used for human consumption and irrigation. The application is created in the PHP programming language and used for faster processing of laboratory data, better assessment of groundwater and surface water quality and a more accurate classification of irrigation water in view of physical, chemical and microbiological issues. Data entered in the tables are analysed according to the limit MAC values, whereas the major anions and cations entered in the application show physical and chemical parameters important for the classification of irrigation water. The application calculates the values of electrical conductivity (EC), total hardness (TH), non-carbonate hardness (NCH), total dissolved solids (TDS), sodium percentage (Na%), sodium adsorption ratio (SAR), residual sodium carbonate (RSC), permeability indeks (PI) and total salts concentration (TSC). In addition to these parameters, the application can be used for checking potential incrustation and corrosion issues when the analysed water is used.

Ključne riječi
chemical analysis of water; physical and chemical parameters; irrigation; incrustation; corrosion; water intended for human consumption

Hrčak ID: 183728

URI
https://hrcak.srce.hr/183728

[hrvatski]

Posjeta: 225 *