hrcak mascot   Srce   HID

Arhiv za higijenu rada i toksikologiju, Vol. 6 No. 4, 1955.

Stručni rad

Occupational abrasion and attrition of teeth

Z. Njemirovskij ; Zavod za odontologiju Medicinskog fakulteta u Zagrebu

Puni tekst: hrvatski, pdf (2 MB) str. 311-314 preuzimanja: 20* citiraj
APA 6th Edition
Njemirovskij, Z. (1955). Profesionalna abrazija i atricija zuba. Arhiv za higijenu rada i toksikologiju, 6 (4), 311-314. Preuzeto s https://hrcak.srce.hr/186536
MLA 8th Edition
Njemirovskij, Z.. "Profesionalna abrazija i atricija zuba." Arhiv za higijenu rada i toksikologiju, vol. 6, br. 4, 1955, str. 311-314. https://hrcak.srce.hr/186536. Citirano 15.02.2019.
Chicago 17th Edition
Njemirovskij, Z.. "Profesionalna abrazija i atricija zuba." Arhiv za higijenu rada i toksikologiju 6, br. 4 (1955): 311-314. https://hrcak.srce.hr/186536
Harvard
Njemirovskij, Z. (1955). 'Profesionalna abrazija i atricija zuba', Arhiv za higijenu rada i toksikologiju, 6(4), str. 311-314. Preuzeto s: https://hrcak.srce.hr/186536 (Datum pristupa: 15.02.2019.)
Vancouver
Njemirovskij Z. Profesionalna abrazija i atricija zuba. Arh Hig Rada Toksikol. [Internet]. 1955 [pristupljeno 15.02.2019.];6(4):311-314. Dostupno na: https://hrcak.srce.hr/186536
IEEE
Z. Njemirovskij, "Profesionalna abrazija i atricija zuba", Arhiv za higijenu rada i toksikologiju, vol.6, br. 4, str. 311-314, 1955. [Online]. Dostupno na: https://hrcak.srce.hr/186536. [Citirano: 15.02.2019.]

Sažetak
When examining 77 glassblowers the author failed to find marked abrasive changes on the upper front teeth as described in the literature (1, 2). The author thinks that with a correct technique of work such changes could not happen. The stem of the glassblower's pipe should be held between the lips, and not with the teeth. 52 workers in a boiler repairing shop have been examined; on 126 teeth attritional changes on the surface have been noticed. As the workers work with pneumatic hammers, the author attributes the changes on the teeth to the necessity of steadying their body and their lower jaw against the trembling caused by the vibration of the pneumatic hammer. The attritional changes develop very slowly and they do not cause any discomfort. The production of secondary dentin protects the dental pulp. Prevention of abrasion in glassblowers is simple and consists in correct working technique. In excessive attritional changes a rubber plate for the sensitive teeth can be constructed.

Hrčak ID: 186536

URI
https://hrcak.srce.hr/186536

[hrvatski]

Posjeta: 58 *