Skoči na glavni sadržaj

Izvorni znanstveni članak

Analysis of Surface Topography and Surface Roughnes of CoCr Alloy Samples by Atomic Force Microscopy

Boris Klaić
Vesna Svetličić
Asja Čelebić
Tea Mišić
Suzana Šegota
Ivo Baučić
Vera Žutić


Puni tekst: hrvatski pdf 426 Kb

str. 306-314

preuzimanja: 1.159

citiraj

Puni tekst: engleski pdf 426 Kb

str. 306-314

preuzimanja: 709

citiraj


Sažetak

The aim of this study was to acquire a three-dimensional qualitative and quantitative nano-scale data of surface topology of electropolished CoCr dental alloy, actually of the two different solid solutions previously described as dendrites and interdendritic regions.
Material and Methods: Ten CoCr alloy samples (Wironit® extra-hard, Bego, Germany) were prepared, cast and electropolished. The surface of the samples was recorded and analysed by atomic force microscopy (AFM), as well as with optical microscope. The AFM imaging and analysis made it possible to observe a surface of the CoCr dental alloy three-dimensionally. It has been understood that the dendritic surface structure of the CoCr alloy consists of clusters of nanocrystallites forming islands (corresponding the dark interdendritic regions on optical micrographs), which emerge from a smooth undulating surface (corresponding the light dendritic regions on optical micrographs).
Results: The 95% confidence interval (p<0.05) for the maximum z-value was from 819,98 to 1020,99 nm, for RMS values from 66,93 to 108,54 nm and for Ra (mean roughness) values from 51,53 to 82,48 nm.
Conclusion: The surface revealed favourable characteristics regarding
roughness, moreover the surface of the alloy can be considered really “smooth”, without any mechanical retentive features for microorganisms’ trapping.

Ključne riječi

Chromium Alloys; Dental Alloys; Technology, Dental

Hrčak ID:

18208

URI

https://hrcak.srce.hr/18208

Datum izdavanja:

6.12.2007.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.887 *