hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20160407214150

A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study

Ramazan Cuneyt Erenoglu   ORCID icon orcid.org/0000-0002-8212-8379 ; Canakkale Onsekiz Mart University, Faculty of Engineering, Department of Geomatics Engineering, 17100, Canakkale, Turkey

Puni tekst: engleski, pdf (1 MB) str. 92-99 preuzimanja: 2.185* citiraj
APA 6th Edition
Erenoglu, R.C. (2018). A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study. Tehnički vjesnik, 25 (1), 92-99. https://doi.org/10.17559/TV-20160407214150
MLA 8th Edition
Erenoglu, Ramazan Cuneyt. "A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study." Tehnički vjesnik, vol. 25, br. 1, 2018, str. 92-99. https://doi.org/10.17559/TV-20160407214150. Citirano 18.05.2021.
Chicago 17th Edition
Erenoglu, Ramazan Cuneyt. "A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study." Tehnički vjesnik 25, br. 1 (2018): 92-99. https://doi.org/10.17559/TV-20160407214150
Harvard
Erenoglu, R.C. (2018). 'A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study', Tehnički vjesnik, 25(1), str. 92-99. https://doi.org/10.17559/TV-20160407214150
Vancouver
Erenoglu RC. A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study. Tehnički vjesnik [Internet]. 2018 [pristupljeno 18.05.2021.];25(1):92-99. https://doi.org/10.17559/TV-20160407214150
IEEE
R.C. Erenoglu, "A Novel Robust Scaling for EDM Calibration Baselines using Monte Carlo Study", Tehnički vjesnik, vol.25, br. 1, str. 92-99, 2018. [Online]. https://doi.org/10.17559/TV-20160407214150

Sažetak
The terrestrial measurements using Electronic Distance Measurement (EDM) have been widely done for different applications such as deformation monitoring and establishing geodetic networks. The calibration of the EDMs reflects the quality of the estimated parameters. In geodesy, least squares principle is mainly used for estimating parameters. The least square estimation is adversely affected by the systematic and non-systematic errors resulting in bias for the estimated parameters. In this study, to compare efficacy of different robust methods, the Monte Carlo simulation is applied to the EDM calibration as well as real experiments. The parameters without errors are obtained as a result of the used methodology. The methods given in this study are basically based on iteratively reweighted least squares and can be used for both parameter estimation and outlier diagnostics. This is of particular importance for calibrations of electromagnetic distance measurements using the Monte Carlo simulation and the measured test baselines. The results showed that one of the advantages of the used methodology is the improvement of the reliability of the estimated calibration parameters.

Ključne riječi
calibration; electronic distance meter; least squares estimation; Monte Carlo simulation; reliability; robust

Hrčak ID: 193600

URI
https://hrcak.srce.hr/193600

Posjeta: 2.547 *