hrcak mascot   Srce   HID

Izvorni znanstveni članak

Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates

H. Furedi ; Department of Physical Chemistry, Institute »Ruder Boskovic «, Zagreb, Croatia, Yugoslavia

Puni tekst: engleski, pdf (6 MB) str. 201-207 preuzimanja: 63* citiraj
APA 6th Edition
Furedi, H. (1961). Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates. Croatica Chemica Acta, 33 (4), 201-207. Preuzeto s https://hrcak.srce.hr/208425
MLA 8th Edition
Furedi, H.. "Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates." Croatica Chemica Acta, vol. 33, br. 4, 1961, str. 201-207. https://hrcak.srce.hr/208425. Citirano 08.03.2021.
Chicago 17th Edition
Furedi, H.. "Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates." Croatica Chemica Acta 33, br. 4 (1961): 201-207. https://hrcak.srce.hr/208425
Harvard
Furedi, H. (1961). 'Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates', Croatica Chemica Acta, 33(4), str. 201-207. Preuzeto s: https://hrcak.srce.hr/208425 (Datum pristupa: 08.03.2021.)
Vancouver
Furedi H. Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates. Croatica Chemica Acta [Internet]. 1961 [pristupljeno 08.03.2021.];33(4):201-207. Dostupno na: https://hrcak.srce.hr/208425
IEEE
H. Furedi, "Application of Microdiffusion Methods for the Determination of Carbon Dioxide in Solid Carbonates", Croatica Chemica Acta, vol.33, br. 4, str. 201-207, 1961. [Online]. Dostupno na: https://hrcak.srce.hr/208425. [Citirano: 08.03.2021.]

Sažetak
A new absorption device is recommended as a modification of
the Cavett apparatus. Its application for the determination of
carbon dioxide in solid carbonates is discussed. Barium carbonate
has been used as a test substance. Determinations of carbon dioxide
were carried out by decomposing the samples with hydrochlor ic
acid, absorbing the evolved gas in bc:rium hydroxide solution and
re-titrating the excess alkali with standard hydrochloric a cid
solution to a thymolblue end-point. Carbon dioxide has been determined
in the range of 0.3-3 mg. with relative standard errors of
18-2Q/o, respectively. Estimations have been made with quantities
of carbon dioxide as low as 70 μg. The results of carbon dioxide
determinations in a precipitate of the system uranyl nitrate -
barium chloride - natrium carbonate - water are shown.