hrcak mascot   Srce   HID

Tehnički vjesnik, Vol. 26 No. 1, 2019.

Stručni rad
https://doi.org/10.17559/TV-20170705153240

Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards

Hovhannes Avagyan   ORCID icon orcid.org/0000-0003-4316-450X ; National University of Architecture and Construction of Armenia, 105 Teryan Street, Yerevan 0009, Republic of Armenia

Puni tekst: engleski, pdf (1 MB) str. 279-282 preuzimanja: 23* citiraj
APA 6th Edition
Avagyan, H. (2019). Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards. Tehnički vjesnik, 26 (1), 279-282. https://doi.org/10.17559/TV-20170705153240
MLA 8th Edition
Avagyan, Hovhannes. "Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards." Tehnički vjesnik, vol. 26, br. 1, 2019, str. 279-282. https://doi.org/10.17559/TV-20170705153240. Citirano 24.03.2019.
Chicago 17th Edition
Avagyan, Hovhannes. "Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards." Tehnički vjesnik 26, br. 1 (2019): 279-282. https://doi.org/10.17559/TV-20170705153240
Harvard
Avagyan, H. (2019). 'Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards', Tehnički vjesnik, 26(1), str. 279-282. doi: https://doi.org/10.17559/TV-20170705153240
Vancouver
Avagyan H. Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards. Tehnički vjesnik [Internet]. 2019 [pristupljeno 24.03.2019.];26(1):279-282. doi: https://doi.org/10.17559/TV-20170705153240
IEEE
H. Avagyan, "Punching Shear Resistance of Slab with Shear Reinforcement According to Armenian and Foreign Building Standards", Tehnički vjesnik, vol.26, br. 1, str. 279-282, 2019. [Online]. doi: https://doi.org/10.17559/TV-20170705153240

Sažetak
The paper presents the results of punching shear values with reinforcement based on calculations of two and four storey cast-in-place reinforced concrete flat plate system buildings with spans of 4 m and 7 m by LIRA, Design Expert and RCM ACI-builder software in accordance with Armenian, Russian, European and American building standards under earthquake loading. In contrast to Eurocode 2 (EN 2) and American Concrete Institute (ACI), the building codes of the Republic of Armenia (SNiP) do not include the influence of bending moment in shear stress equation. The effect of punching shear on both interior and edge columns was carried out. To analyze the systems finite element method (FEM) was used. The results of comparison analysis show that according to SNiP the shear stresses do not exceed the limit even without reinforcement, whereas by foreign standards the differences between peak shear stresses with reinforcement and permissible shear reinforcement are marginal.

Ključne riječi
building standards; earthquake loading; finite element method (FEM); flat plate; shear reinforcement

Hrčak ID: 217155

URI
https://hrcak.srce.hr/217155

Posjeta: 52 *