Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.15644/asc53/1/2

Comparison of Shear Bond Strength Orthodontic Brackets Bonded to Zirconia and Lithium Disilicate Crowns

Blerim Mehmeti ; Department of Orthodontics and Pedodontics, Medical Faculty - School of Dentistry, University of Pristina, Kosovo
Jeta Kelmendi ; Stomatološki fakultet Sveučilišta u Zagrebu – studentica doktorskog studija, Zagreb, Hrvatska
Donika Ilijazi-Shahiqi ; Stomatološki fakultet Sveučilišta u Zagrebu – studentica doktorskog studija, Zagreb, Hrvatska
Bleron Azizi ; Stomatološki fakultet Sveučilišta u Prištini, Kosovo
Suzana Jakovljević ; Zavod za materijale Strojarskog fakulteta Sveučilišta u Zagrebu, Hrvatska
Fehim Haliti ; Zavod za ortodonciju i pedodonciju Medicinskog fakulteta Sveučilišta u Prištini, Kosovo
Sandra Anić-Milošević orcid id orcid.org/0000-0003-2641-2364 ; Zavod za ortodonciju Stomatološkog fakulteta Sveučilišta u Zagrebu, Zagreb, Hrvatska


Puni tekst: hrvatski pdf 1.515 Kb

str. 17-27

preuzimanja: 481

citiraj

Puni tekst: engleski pdf 1.515 Kb

str. 17-27

preuzimanja: 779

citiraj


Sažetak

Aim of this study was to analyze Shear Bond Strength (SBS) and Adhesive Remnant Index (ARI) of ceramic and metallic orthodontic brackets bonded to zirconia or lithium-disilicate ceramics used for
prosthetic restorations, conditioned with hydrofluoric acid (HFA) or phosphoric acid (PhA), as well as to determine the Porcelain Fracture Index (PFI), in order to examine the condition of the ceramic surface after debonding. Material and methods: The research was conducted on 96 prepared all-ceramic samples divided into 8 groups combined from the type of ceramic material, orthodontic brackets, and surface conditioning. SBS was tested with Universal Testing Machine, and the samples were analyzed using a Scanning Electron Microscope, to determine ARI and PFI. Statistical data were processed using ANOVA, with the level of significance α = 0.05. Results: Lithium-disilicate showed better bond strength in almost all groups. However, no significant difference between the groups was noticed and none of the factors had a significant influence on the mean values of SBS (p>0.05). Nevertheless, ARI significantly depended on the type of bracket (p = 0.005), and PFI significantly depended on the type of etchant (p = 0.029). Conclusion: The use of HFA for surface etching of zirconia and lithium-disilicate, does not cause a significant increase in the SBS values as compared to etching with PhA and silane application. Furthermore, HFA can weaken the surface structure of the ceramic, and considering its toxicity, might not be the best suitable conditioner prior to orthodontic bonding to lithium disilicate, and in particular to zirconia, also taking into account its crystalline structure.

Ključne riječi

Orthodontic Brackets; Shear Bond Strength; Crowns; Adhesive Remnant Index (ARI); Porcelain Fracture Index (PFI); Zirconia; Lithium Compounds

Hrčak ID:

217997

URI

https://hrcak.srce.hr/217997

Datum izdavanja:

19.3.2019.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.318 *