hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20180213180751

Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm

Oluwabukola Oke ; Ondokuz Mayis University, Engineering Faculty, Electrical and Electronic Engineering Department, 55200 Atakum, Samsun, Turkey
Okan Ozgonenel ; Ondokuz Mayis University, Engineering Faculty, Electrical and Electronic Engineering Department, Head of Department, 55200 Atakum, Samsun, Turkey
David W. P. Thomas ; Ondokuz Mayis University, Engineering Faculty, Electrical and Electronic Engineering Department, 55200 Atakum, Samsun, Turkey
Mustafa Serdar Ataseven ; Ondokuz Mayis University, Engineering Faculty, Electrical and Electronic Engineering Department, 55200 Atakum, Samsun, Turkey

Puni tekst: engleski, pdf (1 MB) str. 1260-1266 preuzimanja: 61* citiraj
APA 6th Edition
Oke, O., Ozgonenel, O., Thomas, D.W.P. i Ataseven, M.S. (2019). Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm. Tehnički vjesnik, 26 (5), 1260-1266. https://doi.org/10.17559/TV-20180213180751
MLA 8th Edition
Oke, Oluwabukola, et al. "Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm." Tehnički vjesnik, vol. 26, br. 5, 2019, str. 1260-1266. https://doi.org/10.17559/TV-20180213180751. Citirano 15.11.2019.
Chicago 17th Edition
Oke, Oluwabukola, Okan Ozgonenel, David W. P. Thomas i Mustafa Serdar Ataseven. "Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm." Tehnički vjesnik 26, br. 5 (2019): 1260-1266. https://doi.org/10.17559/TV-20180213180751
Harvard
Oke, O., et al. (2019). 'Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm', Tehnički vjesnik, 26(5), str. 1260-1266. https://doi.org/10.17559/TV-20180213180751
Vancouver
Oke O, Ozgonenel O, Thomas DWP, Ataseven MS. Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm. Tehnički vjesnik [Internet]. 2019 [pristupljeno 15.11.2019.];26(5):1260-1266. https://doi.org/10.17559/TV-20180213180751
IEEE
O. Oke, O. Ozgonenel, D.W.P. Thomas i M.S. Ataseven, "Probabilistic Load Flow of Unbalanced Distribution Systems with Wind Farm", Tehnički vjesnik, vol.26, br. 5, str. 1260-1266, 2019. [Online]. https://doi.org/10.17559/TV-20180213180751

Sažetak
This paper examines the practical application of the Unscented Transform (UT) method in carrying out load flow studies in distributions systems with embedded generation and unbalanced loading. A hybrid ladder network based backward/forward sweep technique was employed in solving the distribution system load flow. The performance of the load flow technique plus the UT method is demonstrated using a real 44-Bus unbalanced distribution system with a proposed wind farm which is located in Samsun, Northern Turkey. Results obtained were compared with those from the Monte Carlo Simulation method while the effect of the wind farm on the existing network was also evaluated.

Ključne riječi
Monte Carlo simulation; probabilistic load flow; unbalance; uncertainty; unscented transforms; wind energy

Hrčak ID: 226007

URI
https://hrcak.srce.hr/226007

Posjeta: 103 *