hrcak mascot   Srce   HID

Prethodno priopćenje
https://doi.org/10.31803/tg-20180123123455

Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System

Barış Kavasoğullari*   ORCID icon orcid.org/0000-0002-6086-8923 ; Osmaniye Korkut Ata University, Mechanical Engineering Department, Karacaoğlan Yerleşkesi Fakıuşağı Mah. 80000 Merkez/Osmaniye, Turkey
Ertuğrul Cihan ; Osmaniye Korkut Ata University, Mechanical Engineering Department, Karacaoğlan Yerleşkesi Fakıuşağı Mah. 80000 Merkez/Osmaniye, Turkey
Hasan Demir   ORCID icon orcid.org/0000-0002-9278-9648 ; Osmaniye Korkut Ata University, Chemical Engineering Department, Karacaoğlan Yerleşkesi Fakıuşağı Mah. 80000 Merkez/Osmaniye, Turkey

Puni tekst: engleski, pdf (1 MB) str. 36-40 preuzimanja: 73* citiraj
APA 6th Edition
Kavasoğullari*, B., Cihan, E. i Demir, H. (2020). Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System. Tehnički glasnik, 14 (1), 36-40. https://doi.org/10.31803/tg-20180123123455
MLA 8th Edition
Kavasoğullari*, Barış, et al. "Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System." Tehnički glasnik, vol. 14, br. 1, 2020, str. 36-40. https://doi.org/10.31803/tg-20180123123455. Citirano 08.08.2020.
Chicago 17th Edition
Kavasoğullari*, Barış, Ertuğrul Cihan i Hasan Demir. "Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System." Tehnički glasnik 14, br. 1 (2020): 36-40. https://doi.org/10.31803/tg-20180123123455
Harvard
Kavasoğullari*, B., Cihan, E., i Demir, H. (2020). 'Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System', Tehnički glasnik, 14(1), str. 36-40. https://doi.org/10.31803/tg-20180123123455
Vancouver
Kavasoğullari* B, Cihan E, Demir H. Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System. Tehnički glasnik [Internet]. 2020 [pristupljeno 08.08.2020.];14(1):36-40. https://doi.org/10.31803/tg-20180123123455
IEEE
B. Kavasoğullari*, E. Cihan i H. Demir, "Energy and Exergy Analysis of LiBr-aq and LiCl-aq Liquid Desiccant Dehumidification System", Tehnički glasnik, vol.14, br. 1, str. 36-40, 2020. [Online]. https://doi.org/10.31803/tg-20180123123455

Sažetak
In this study, energy and exergy analysis of experimental results obtained from a dehumidification system using LiBr-aq (lithium bromide-water) and LiCl-aq (lithium chloride-water) as desiccant was made. In dehumidifier and regenerator columns polycarbonate sheets, which have not been used before, were used as packing material to increase contact area in purposed liquid desiccant dehumidification system. In the analysis, variation of electrical coefficient of performance and exergy efficiency with airflow rate for different solution mass flow rates were investigated. Because of investigation, maximum values of electrical coefficient of performance and exergy efficiency were calculated approximately as 2.8 and 18%, respectively.

Ključne riječi
energy; exergy; liquid desiccant; liquid desiccant dehumidification; polycarbonate packing

Hrčak ID: 235961

URI
https://hrcak.srce.hr/235961

Posjeta: 143 *