hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.2478/aiht-2020-71-3318

Kiralna separacija beta-blokatora tekućinskom kromatografijom visoke djelotvornosti i određivanje enantiomera bisoprolola u površinskim vodama

Marijana Pocrnić   ORCID icon orcid.org/0000-0002-2314-2656 ; Department of Chemistry, Faculty of Science, University of Zagreb, Zagreb, Croatia
Martin Ansorge ; Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
Magda Dovhunová   ORCID icon orcid.org/0000-0002-2130-3268 ; Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
Eva Tesařová ; Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Prague, Czech Republic
Nives Galić ; Department of Chemistry, Faculty of Science, University of Zagreb, Zagreb, Croatia

Puni tekst: engleski, pdf (348 KB) str. 56-62 preuzimanja: 150* citiraj
APA 6th Edition
Pocrnić, M., Ansorge, M., Dovhunová, M., Tesařová, E. i Galić, N. (2020). Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters. Arhiv za higijenu rada i toksikologiju, 71 (1), 56-62. https://doi.org/10.2478/aiht-2020-71-3318
MLA 8th Edition
Pocrnić, Marijana, et al. "Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters." Arhiv za higijenu rada i toksikologiju, vol. 71, br. 1, 2020, str. 56-62. https://doi.org/10.2478/aiht-2020-71-3318. Citirano 03.03.2021.
Chicago 17th Edition
Pocrnić, Marijana, Martin Ansorge, Magda Dovhunová, Eva Tesařová i Nives Galić. "Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters." Arhiv za higijenu rada i toksikologiju 71, br. 1 (2020): 56-62. https://doi.org/10.2478/aiht-2020-71-3318
Harvard
Pocrnić, M., et al. (2020). 'Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters', Arhiv za higijenu rada i toksikologiju, 71(1), str. 56-62. https://doi.org/10.2478/aiht-2020-71-3318
Vancouver
Pocrnić M, Ansorge M, Dovhunová M, Tesařová E, Galić N. Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters. Arh Hig Rada Toksikol. [Internet]. 2020 [pristupljeno 03.03.2021.];71(1):56-62. https://doi.org/10.2478/aiht-2020-71-3318
IEEE
M. Pocrnić, M. Ansorge, M. Dovhunová, E. Tesařová i N. Galić, "Chiral separation of beta-blockers by high-performance liquid chromatography and determination of bisoprolol enantiomers in surface waters", Arhiv za higijenu rada i toksikologiju, vol.71, br. 1, str. 56-62, 2020. [Online]. https://doi.org/10.2478/aiht-2020-71-3318

Sažetak
Beta-blokatori su kiralni spojevi s enantiomerima različite bioaktivnosti, dakle, dok je jedan enantiomer aktivan, drugi može biti neaktivan ili čak štetan za organizam. Zbog njihove visoke potrošnje i nepotpune razgradnje u pogonima za preradu otpadnih voda, postoji mogućnost da se pojave u prirodnim vodama i negativno utječu na vodene organizme. Stoga je u ovom radu razvijena kromatografska metoda za određivanje enantiomera beta-blokatora u prirodnim vodama. Metoda je testirana na pet beta-blokatora (acebutolol, atenolol, bisoprolol, labetalol i metoprolol) te validirana za enantiomere bisoprolola. Dobra enantioseparacija svih analiziranih beta-blokatora postignuta je na koloni Chirobiotic V sastava mobilne faze metanol/octena kiselina/trietilamin (100:0,2:0,15 v/v/v) pri protoku od 0,5 mL/min i temperaturi od 45 °C. Metodom je postignuta dobra linearnost u području od 0,075 μg/mL do 5 μg/mL s dobrim analitičkim povratom. Granice detekcije pojedinih enantiomera bisoprolola bile su 0,025 μg/mL i 0,026 μg/mL, a granice kvantifikacije 0,075 μg/ mL za oba enantiomera. Unatoč ograničenjima metode, pokazala se kao obećavajuća metoda analize enantiomera bisoprolola u površinskim vodama. Daljnja istraživanja mogla bi se izvoditi na otpadnim vodama, gdje bi koncentracije enantiomera mogle biti više. Također, korištenjem osjetljivije metode, primjerice vezanoga sustava tekućinske kromatografije i tandemne spektrometrije masa, te korištenjem amonijeva acetata kao aditiva mobilnoj fazi umjesto octene kiseline i trietilamina, mogle bi se postići znatno niže granice detekcije i kvantifikacije.

Ključne riječi
acebutolol; analiza vode; atenolol; Chirobiotic V kolona; Češka; enantioseparacija; HPLC; Hrvatska; labetalol; metoprolol

Hrčak ID: 236210

URI
https://hrcak.srce.hr/236210

[engleski]

Posjeta: 351 *