Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.2478/aiht-2020-71-3403

Potential benefit of retrospective use of neutron monitors in improving ionising radiation exposure assessment on international flights: issues raised by neutron passive dosimeter measurements and EPCARD simulations during sudden changes in solar activity

Marina Poje Sovilj ; Josip Juraj Strossmayer University of Osijek, Department of Physics, Osijek, Croatia
Branko Vuković ; Josip Juraj Strossmayer University of Osijek, Department of Physics, Osijek, Croatia
Vanja Radolić ; Josip Juraj Strossmayer University of Osijek, Department of Physics, Osijek, Croatia
Igor Miklavčić ; Josip Juraj Strossmayer University of Osijek, Department of Physics, Osijek, Croatia
Denis Stanić ; Josip Juraj Strossmayer University of Osijek, Department of Physics, Osijek, Croatia


Puni tekst: engleski pdf 792 Kb

str. 152-157

preuzimanja: 338

citiraj


Sažetak

Since air transport became more accessible, more and more people have been exposed to ionising radiation of cosmic origin. Measuring the neutron dose equivalent is a good approximation of total ambient dose equivalent, as neutrons carry about 50 % of the dose at flight altitudes. The aim of our study was to compare our measurements of the neutron component of secondary cosmic radiation dose, taken with passive dosimeters, with the data obtained from a simulation generated by EPCARD software, which is common in assessing flight crew exposure to ionising radiation. We observed deviations (both above and below) from the expected proportion of the neutron component (between 40 and 80 %), which pointed to certain issues with actual passive dosimeter measurement and the EPCARD simulation. The main limitation of the dosimeter are large uncertainties in high energy neutron response, which may result in underestimation of neutron dose equivalent. The main drawback of the software simulation is monthly averaging of solar potential in calculations, which can neglect sporadic high energy events. Since airlines worldwide almost exclusively use software (due to costs and convenience) to estimate the dose received by their crew, it is advisable to retrospectively recalculate the dose taking into account neutron monitor readings when solar activity changes.

Ključne riječi

aviation route doses; cosmic radiation; EPCARD; nuclear track-etched detector; solar activity

Hrčak ID:

239264

URI

https://hrcak.srce.hr/239264

Datum izdavanja:

17.6.2020.

Podaci na drugim jezicima: hrvatski

Posjeta: 1.015 *