hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20200529182437

Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI

Karuppanasamy Chandrasekaran*   ORCID icon orcid.org/0000-0001-5551-789X ; PPG Institute of Technology, Saravanampatty Post, Coimbatore-641035
Rajendran Arthanari ; Karpagam college of Engineering, Othakalmandabam, Coimbatore-641032

Puni tekst: engleski, pdf (1 MB) str. 439-446 preuzimanja: 36* citiraj
APA 6th Edition
Chandrasekaran*, K. i Arthanari, R. (2021). Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI. Tehnički vjesnik, 28 (2), 439-446. https://doi.org/10.17559/TV-20200529182437
MLA 8th Edition
Chandrasekaran*, Karuppanasamy i Rajendran Arthanari. "Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI." Tehnički vjesnik, vol. 28, br. 2, 2021, str. 439-446. https://doi.org/10.17559/TV-20200529182437. Citirano 12.05.2021.
Chicago 17th Edition
Chandrasekaran*, Karuppanasamy i Rajendran Arthanari. "Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI." Tehnički vjesnik 28, br. 2 (2021): 439-446. https://doi.org/10.17559/TV-20200529182437
Harvard
Chandrasekaran*, K., i Arthanari, R. (2021). 'Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI', Tehnički vjesnik, 28(2), str. 439-446. https://doi.org/10.17559/TV-20200529182437
Vancouver
Chandrasekaran* K, Arthanari R. Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI. Tehnički vjesnik [Internet]. 2021 [pristupljeno 12.05.2021.];28(2):439-446. https://doi.org/10.17559/TV-20200529182437
IEEE
K. Chandrasekaran* i R. Arthanari, "Fuzzy Controlled THD Reduction and Performance Improvement of a PMBLDC Motor Using MMLI", Tehnički vjesnik, vol.28, br. 2, str. 439-446, 2021. [Online]. https://doi.org/10.17559/TV-20200529182437

Sažetak
In this study, an improved chopper is implemented for current extraction, enhanced solar power generation control, and increased voltage. A simplified space vector control technique is applied to operate the permanent-magnet brushless DC drive (PMBLDC) by controlling the inverter operation. This is used as a special electrical machine with reliable operation and maintenance control. This system uses the Perturb and observer (P&O) algorithm which maximises the PV-system output power and reduces the overall cost. A fuzzy logic controller (FLC) is used to control the duty cycle and increase the PV voltage. The modified multilevel inverter (MMLI) reduces harmonic distortions and low-switching losses by using a self-tuning filter (STF). This study achieved a better PMBLDC system performance, an improved efficiency, and eliminated the total harmonic distortion (THD) by the self-tuning filter with and without using MATLAB/SIMULINK.

Ključne riječi
Active Power Filter; Boost converter; Fuzzy logic controller; Maximum Power Point Tracking; Multilevel Inverter; Permanent Magnet Brushless DC Drive;

Hrčak ID: 255810

URI
https://hrcak.srce.hr/255810

Posjeta: 77 *