hrcak mascot   Srce   HID

Izvorni znanstveni članak

Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom

Alena Knežević
Zrinka Tarle
Andrej Meniga
Jozo Šutalo
Goran Pichler
Mira Ristić

Puni tekst: hrvatski, pdf (79 KB) str. 159-164 preuzimanja: 466* citiraj
APA 6th Edition
Knežević, A., Tarle, Z., Meniga, A., Šutalo, J., Pichler, G. i Ristić, M. (2003). Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom. Acta stomatologica Croatica, 37 (2), 159-164. Preuzeto s https://hrcak.srce.hr/2565
MLA 8th Edition
Knežević, Alena, et al. "Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom." Acta stomatologica Croatica, vol. 37, br. 2, 2003, str. 159-164. https://hrcak.srce.hr/2565. Citirano 26.05.2020.
Chicago 17th Edition
Knežević, Alena, Zrinka Tarle, Andrej Meniga, Jozo Šutalo, Goran Pichler i Mira Ristić. "Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom." Acta stomatologica Croatica 37, br. 2 (2003): 159-164. https://hrcak.srce.hr/2565
Harvard
Knežević, A., et al. (2003). 'Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom', Acta stomatologica Croatica, 37(2), str. 159-164. Preuzeto s: https://hrcak.srce.hr/2565 (Datum pristupa: 26.05.2020.)
Vancouver
Knežević A, Tarle Z, Meniga A, Šutalo J, Pichler G, Ristić M. Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom. Acta stomatologica Croatica [Internet]. 2003 [pristupljeno 26.05.2020.];37(2):159-164. Dostupno na: https://hrcak.srce.hr/2565
IEEE
A. Knežević, Z. Tarle, A. Meniga, J. Šutalo, G. Pichler i M. Ristić, "Mjerenje konverzije i temperature kompozita polimeriziranih halogenim i LED polimerizatorom", Acta stomatologica Croatica, vol.37, br. 2, str. 159-164, 2003. [Online]. Dostupno na: https://hrcak.srce.hr/2565. [Citirano: 26.05.2020.]
Puni tekst: engleski, pdf (68 KB) str. 165-168 preuzimanja: 2.095* citiraj
APA 6th Edition
Knežević, A., Tarle, Z., Meniga, A., Šutalo, J., Pichler, G. i Ristić, M. (2003). Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit. Acta stomatologica Croatica, 37 (2), 165-168. Preuzeto s https://hrcak.srce.hr/2565
MLA 8th Edition
Knežević, Alena, et al. "Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit." Acta stomatologica Croatica, vol. 37, br. 2, 2003, str. 165-168. https://hrcak.srce.hr/2565. Citirano 26.05.2020.
Chicago 17th Edition
Knežević, Alena, Zrinka Tarle, Andrej Meniga, Jozo Šutalo, Goran Pichler i Mira Ristić. "Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit." Acta stomatologica Croatica 37, br. 2 (2003): 165-168. https://hrcak.srce.hr/2565
Harvard
Knežević, A., et al. (2003). 'Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit', Acta stomatologica Croatica, 37(2), str. 165-168. Preuzeto s: https://hrcak.srce.hr/2565 (Datum pristupa: 26.05.2020.)
Vancouver
Knežević A, Tarle Z, Meniga A, Šutalo J, Pichler G, Ristić M. Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit. Acta stomatologica Croatica [Internet]. 2003 [pristupljeno 26.05.2020.];37(2):165-168. Dostupno na: https://hrcak.srce.hr/2565
IEEE
A. Knežević, Z. Tarle, A. Meniga, J. Šutalo, G. Pichler i M. Ristić, "Degree of Conversion and Temperature Measurement of Composite Polymerised with Halogen and LED-Curing Unit", Acta stomatologica Croatica, vol.37, br. 2, str. 165-168, 2003. [Online]. Dostupno na: https://hrcak.srce.hr/2565. [Citirano: 26.05.2020.]

Sažetak
Današnji kompozitni materijali polimeriziraju se vidljivim plavim svjetlom valne duljine oko 468 nm. Komercijalni uređaji za polimerizaciju kompozitnih materijala emitiraju plavo svjetlo različite jakosti. Uporaba uređaja za polimerizaciju jačega intenziteta sa svrhom da se postigne veći stupanj konverzije neminovno povećava zagrijavanje i temperaturu u materijalu tijekom stvrdnjavanja te polimerizacijski skuplja materijal. Svrha rada bila je utvrditi postoji li razlika između stupnja konverzije i porasta temperature triju ispitivanih kompozitnih materijala: Amelogen (Akeda Dental, Danska), Pertac II (ESPE, Seefeld, Germany), Z100 (3M Dental Products, St. Paul, Minessotta, USA), polimeriziranih eksponencijskim programom Elipar Trilight (ESPE, Seefeld, Njemačka) polimerizatora i Lux-o-Max (Akeda Dental, Danska) uređajem za polimerizaciju temeljenog na LED (light emitting diodes) tehnologiji. Rezultati su pokazali tek nešto niži stupanj konverzije pri polimerizaciji Lux-o-Max uređajem u odnosu prema eksponencijskome programu Elipar Trilight polimerizatora. Temperaturni porast znatno je niži pri polimerizaciji Lux-o-Max uređajem za sve ispitivane kompozitne materijale u usporedbi s rezultatima dobivenima pri polimerizaciji eksponencijskim programom Elipar Trilight polimerizatora.

Ključne riječi
halogeni polimerizator; plave diode; kompozitni materijali; stupanj konverzije; temperatura

Hrčak ID: 2565

URI
https://hrcak.srce.hr/2565

[engleski]

Posjeta: 2.957 *