Skoči na glavni sadržaj

Izvorni znanstveni članak

MR Assessment of Bile Duct Size in Healthy Individuals: Comparison with US Measurements

Gordana Lovrenčić Prpić
Nenad Babić
Domagoj Marjan
Marija Pećina
Miljenko Marotti


Puni tekst: engleski pdf 95 Kb

str. 567-571

preuzimanja: 531

citiraj


Sažetak

The purpose of the study was to determine the difference in extrahepatic bile duct (EBD) size measured by magnetic
resonance (MR) compared with those measured by ultrasound (US). Changes of EBD size related to aging were analyzed
too. Size of EBD was measured in 76 randomly selected healthy individuals. Three radiologists blinded to the result of
other study preformed measurements by US and three different T2 weighted MR sequences. Correlation and linear regression
analysis of obtained data were performed. The mean diameter of EBD measured by US was 3.17mmand by MR
was 3.14 mm on thick slab rapid acquisition with relaxation enhancement (TSE), 3.26 mm on thin section single-shot
TSE (HASTE) and 3.30 mm on coronal fully rewound gradient echo (True FISP). There was no statistical difference between
US and different MR sequences (p<0.05). A trend of increase of EBD with age (0.0155 mm per year, p=0.0954)
was observed. Size of EBD highly correlated for each MR sequence with US measurement validating use of MR as a reliable
method for evaluation of EBD size. This conclusion is stressed by increase of EBD size with age demonstrated by all
measuring methods

Ključne riječi

bile duct; magnetic resonance; ultrasound

Hrčak ID:

27398

URI

https://hrcak.srce.hr/27398

Datum izdavanja:

10.4.2007.

Posjeta: 925 *