Stručni rad

Variation of vascular ring as a cause of extubation failure

IVANCICA SKARIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
JASMINKA JAKOBOVIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
MAJA KARAMAN ILIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
KARMEN KONDZA ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia
IRENA BABIC ; Children's Hospital Zagreb; Department of anesthesiology, reanimatology and intensive care; Klaićeva 16, 10000 Zagreb, Croatia

Puni tekst: engleski, pdf (177 KB) str. 29-31 preuzimanja: 354* citiraj
APA 6th Edition
SKARIC, I., JAKOBOVIC, J., KARAMAN ILIC, M., KONDZA, K. i BABIC, I. (2008). Variation of vascular ring as a cause of extubation failure. Signa vitae, 3 (2), 29-31. Preuzeto s https://hrcak.srce.hr/28698
MLA 8th Edition
SKARIC, IVANCICA, et al. "Variation of vascular ring as a cause of extubation failure." Signa vitae, vol. 3, br. 2, 2008, str. 29-31. https://hrcak.srce.hr/28698. Citirano 22.09.2019.
Chicago 17th Edition
SKARIC, IVANCICA, JASMINKA JAKOBOVIC, MAJA KARAMAN ILIC, KARMEN KONDZA i IRENA BABIC. "Variation of vascular ring as a cause of extubation failure." Signa vitae 3, br. 2 (2008): 29-31. https://hrcak.srce.hr/28698
Harvard
SKARIC, I., et al. (2008). 'Variation of vascular ring as a cause of extubation failure', Signa vitae, 3(2), str. 29-31. Preuzeto s: https://hrcak.srce.hr/28698 (Datum pristupa: 22.09.2019.)
Vancouver
SKARIC I, JAKOBOVIC J, KARAMAN ILIC M, KONDZA K, BABIC I. Variation of vascular ring as a cause of extubation failure. Signa vitae [Internet]. 2008 [pristupljeno 22.09.2019.];3(2):29-31. Dostupno na: https://hrcak.srce.hr/28698
IEEE
I. SKARIC, J. JAKOBOVIC, M. KARAMAN ILIC, K. KONDZA i I. BABIC, "Variation of vascular ring as a cause of extubation failure", Signa vitae, vol.3, br. 2, str. 29-31, 2008. [Online]. Dostupno na: https://hrcak.srce.hr/28698. [Citirano: 22.09.2019.]

Sažetak
We report on an unexpected extubation failure in a two year old boy. In our patient, failure of extubation led to a diagnostic examination. The result of our examination was discovery of a congenital anomaly of the aortic arch and great vessels (vascular ring) with compression of the trachea. The presence of this anomaly in this patient was unknown to us before. A successful surgical procedure eliminated the underlying cause of the persistent extubation failures.

Ključne riječi
tracheal compression; vascular ring; extubation failure

Hrčak ID: 28698

URI
https://hrcak.srce.hr/28698

Posjeta: 602 *