Vibration Analysis of Heat Exchangers of a Nitric Acid Plant

I. Šoljić ; Faculty of Chemical Engineering and Technology, University of Zagreb, Savska c. 16, Zagreb, Croatia
Lj. Matijašević ; Faculty of Chemical Engineering and Technology, University of Zagreb, Savska c. 16, Zagreb, Croatia
I. Dejanović ; Faculty of Chemical Engineering and Technology, University of Zagreb, Savska c. 16, Zagreb, Croatia


Puni tekst: engleski pdf 1.990 Kb

str. 287-294

preuzimanja: 1.744

citiraj


Sažetak

This paper deals with an operational problem of two heat exchangers of the nitric acid synthesis plant. Detailed calculation and vibration analysis were made and vibration problem of the nitrous gases cooler E-111 was identified. When the vibration problem was indicated, several steps were taken for its removal. For five different types of baffles a study was made to determine how their number and spacing influence the cross-flow rate of the fluid. Results showed that the vibration problem cannot be removed completely, but it can be reduced considerably with different types of baffles. Also, the analysis showed that the cooling water condenser E-114 does not have a vibration problem.

Ključne riječi

Heat exchangers; vibration analysis; baffles; tube failure

Hrčak ID:

40925

URI

https://hrcak.srce.hr/40925

Datum izdavanja:

29.9.2009.

Posjeta: 2.202 *