hrcak mascot   Srce   HID

Prethodno priopćenje

IMPLEMENTATION OF ELECTROMOTORS IN EXPLOSIVE ENVIRONMENTS – EXPERIMENTAL INVESTIGATIONS OF FIRE RISKS

Ivica Gavranić ; Agencija za prostore ugrožene eksplozivnom atmosferom, Zagreb, Hrvatska

Puni tekst: hrvatski, pdf (512 KB) str. 207-214 preuzimanja: 1.476* citiraj
APA 6th Edition
Gavranić, I. (2009). PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA. Sigurnost, 51 (3), 207-214. Preuzeto s https://hrcak.srce.hr/41042
MLA 8th Edition
Gavranić, Ivica. "PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA." Sigurnost, vol. 51, br. 3, 2009, str. 207-214. https://hrcak.srce.hr/41042. Citirano 23.10.2021.
Chicago 17th Edition
Gavranić, Ivica. "PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA." Sigurnost 51, br. 3 (2009): 207-214. https://hrcak.srce.hr/41042
Harvard
Gavranić, I. (2009). 'PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA', Sigurnost, 51(3), str. 207-214. Preuzeto s: https://hrcak.srce.hr/41042 (Datum pristupa: 23.10.2021.)
Vancouver
Gavranić I. PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA. Sigurnost [Internet]. 2009 [pristupljeno 23.10.2021.];51(3):207-214. Dostupno na: https://hrcak.srce.hr/41042
IEEE
I. Gavranić, "PRIMJENA ELEKTROMOTORA U EKSPLOZIVNOJ ATMOSFERI - EKSPERIMENTALNA ISTRAŽIVANJA RIZIKA PALJENJA", Sigurnost, vol.51, br. 3, str. 207-214, 2009. [Online]. Dostupno na: https://hrcak.srce.hr/41042. [Citirano: 23.10.2021.]

Sažetak
SUMMARY: The paper deals with risks of electromotor implementation in spaces endangered by a flammable atmosphere. The central part of this paper analyzes the probability of formation of combustion agents due to asynchronous engine cage damage in such spaces. The investigation of combustion agent effectiveness, in conditions where flammable media were present, was conducted on an electromotor belonging to the “Increased Safety Ex e” anti-explosion protection type, whose power equals 47 kW and whose nominal input voltage equals 380 V. Different levels of asynchronous engine cage damage were tested in an explosive atmosphere created by flammable gasses. The reliability of “ON-LINE” methods for technical diagnostics of the condition of the electromotor, used to detect damages in the engine cage which could cause combustion of explosive compounds, was tested separately.

Ključne riječi
explosive atmosphere; electromotor; engine cage damage; technical diagnostics; anti-explosion protection; risk; explosion

Hrčak ID: 41042

URI
https://hrcak.srce.hr/41042

[hrvatski]

Posjeta: 1.888 *