hrcak mascot   Srce   HID

Original scientific paper

Procedure for determination of harmonic distortion along the distribution network

Marinko Stojkov ; Sveučilište J. J. Strossmayera u Osijeku, Strojarski fakultet Slavonski Brod, 35000 Slavonski Brod, Croatia
Kruno Trupinić ; HEP-ODS d.o.o., Elektra Slavonski Brod, 35000 Slavonski Brod, Croatia
Srete Nikolovski ; Sveučilište J. J. Strossmayera u Osijeku, Elektrotehnički fakultet Osijek, 31000 Osijek, Croatia

Fulltext: english, pdf (343 KB) pages 1-26 downloads: 904* cite
APA 6th Edition
Stojkov, M., Trupinić, K. & Nikolovski, S. (2009). Procedure for determination of harmonic distortion along the distribution network. Tehnički vjesnik, 16 (4), 1-26. Retrieved from https://hrcak.srce.hr/45719
MLA 8th Edition
Stojkov, Marinko, et al. "Procedure for determination of harmonic distortion along the distribution network." Tehnički vjesnik, vol. 16, no. 4, 2009, pp. 1-26. https://hrcak.srce.hr/45719. Accessed 21 Sep. 2021.
Chicago 17th Edition
Stojkov, Marinko, Kruno Trupinić and Srete Nikolovski. "Procedure for determination of harmonic distortion along the distribution network." Tehnički vjesnik 16, no. 4 (2009): 1-26. https://hrcak.srce.hr/45719
Harvard
Stojkov, M., Trupinić, K., and Nikolovski, S. (2009). 'Procedure for determination of harmonic distortion along the distribution network', Tehnički vjesnik, 16(4), pp. 1-26. Available at: https://hrcak.srce.hr/45719 (Accessed 21 September 2021)
Vancouver
Stojkov M, Trupinić K, Nikolovski S. Procedure for determination of harmonic distortion along the distribution network. Tehnički vjesnik [Internet]. 2009 [cited 2021 September 21];16(4):1-26. Available from: https://hrcak.srce.hr/45719
IEEE
M. Stojkov, K. Trupinić and S. Nikolovski, "Procedure for determination of harmonic distortion along the distribution network", Tehnički vjesnik, vol.16, no. 4, pp. 1-26, 2009. [Online]. Available: https://hrcak.srce.hr/45719. [Accessed: 21 September 2021]

Abstracts
This paper underlines the importance of permanent power quality measures in distribution network and proposes the interval and event (change in topology) based time schedule of measurements in depth of the network. Some nodes do not need to be measured during 7 days according to EN 50160 to realize that there are great problems to solve in a new technical resolution. Similar to the trend of entropy, true harmonic distortion (THD) in distribution power system is expected to increment, so - momentary measures are sufficient to mark subparts of the power system with unsatisfactory level of power quality. The most important problem to solve is to mark the consumer's generated harmonic distortion. Importance and benefit of the proposed method is to save the time needed to name causes of disturbances (consumer or device) and to anticipate the repairing of power quality. A new flow-chart is suggested for recognition of the consumer THD generation amount. Also, it leads to better technical or managing decision making during maintenance and investment planning activities. Further results of systematic planned measures that need to be done along the distribution power network, will enable global recognition of THD causes in network and simultaneously give exact solutions.

Keywords
consumer; harmonic distortion; power quality; source recognition

Hrčak ID: 45719

URI
https://hrcak.srce.hr/45719

[croatian]

Visits: 1.415 *