Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.5513/JCEA01/17.2.1708

The uptake and release of humidity by wool irradiated with electron beam

Zuzana HANZLÍKOVÁ ; Department of Chemistry, Faculty of Natural Sciences, Constantine the Philosopher University, Tr. A. Hlinku 1, 949 74 Nitra, Slovak Republic
Jana BRANIŠA ; Department of Chemistry, Faculty of Natural Sciences, Constantine the Philosopher University, Tr. A. Hlinku 1, 949 74 Nitra, Slovak Republic
Ján ONDRUŠKA ; Department of Physics, Faculty of Natural Sciences, Constantine the Philosopher University, Tr. A. Hlinku 1, 949 74 Nitra, Slovak Republic
Mária PORUBSKÁ ; Department of Chemistry, Faculty of Natural Sciences, Constantine the Philosopher University, Tr. A. Hlinku 1, 949 74 Nitra, Slovak Republic


Puni tekst: engleski pdf 552 Kb

str. 315-324

preuzimanja: 479

citiraj


Sažetak

In this work, wool samples a) degreased and stored in desiccator (WD), b) degreased and stored freely (WF), c) cleaned in water and stored freely (WW) were irradiated by accelerated electron beam with doses within the range (0-400) kGy in air. Content of S-sulphonate as primary oxidation product was determined in WD using FTIR spectra inverted in the second-order derivative spectra. The uptake of humidity by all the samples at room temperature and 97% relative humidity was examined gravimetrically. As expected, the highest humidity uptake was observed for WD and the smallest one for WW. Development of the humidity uptake showed some fluctuation for all samples and, for WD the fluctuation corresponded with generated S-sulphonate, presumably due to formation of numerous H-bonds. The increasing uptake of humidity for WD and WW was observed up to 40 kGy dose while for WF, the uptake decreased below the initial level already from 16 kGy. Surface tension was measured using sink-float method combining stalagmometry. The initial surface tension of WW was higher than for WD and WF but, grew equally for all samples from 25 kGy. From 100 kGy dose the surface tension showed stabilized level. The humidity release by WD was measured using thermogravimetry. Variation of the rate humidity release around 100 °C, adequate for desorption of weakly bound water, and the mass residue of the heated wool for 120 °C corresponding to release of total water, showed an inverse dependence. It was concluded that content of S-sulphonate is responsible for variability of the sorption properties. The more S-sulphonate formed, the higher uptake of humidity and the lower rate of humidity release that can be observed. It is suggested that, within a certain range, a properly chosen dose can affect humidity uptake.

Ključne riječi

electron beam irradiation; humidity uptake; release; surface tension; wool

Hrčak ID:

158952

URI

https://hrcak.srce.hr/158952

Datum izdavanja:

2.6.2016.

Podaci na drugim jezicima: slovački

Posjeta: 1.393 *