Skoči na glavni sadržaj

Izvorni znanstveni članak

Comparing of the directly determined ERPF with the two- compartmental calculation model

Marjan Erjavec
Gorazd Noč
Sergej Pahor


Puni tekst: hrvatski pdf 815 Kb

str. 9-10

preuzimanja: 128

citiraj

Puni tekst: engleski pdf 815 Kb

str. 9-10

preuzimanja: 127

citiraj


Sažetak

Effective renal plasma flow (ERPF, 131-1 hippuran clearence) was calculated in 6 apparently healthy volunteers, (a) by the single compartment kinetic model according to Blaufox et al.; (b) by the empirical method according to Schlegel and Gates; and (c) by the solid-diffusion kinetic model according to Cerar et al. The obtained values were compared with renal clearence directly determined in steady state during prolonged infusion of the radiopharmaceutical.
Correlation factors and slopes of regression lines were as follows:
Blaufox et al.: 0.780 and 35°
Schlegel and Gates: 0.529 and 36°
Cerar et al.: 0.805 and 47°

Ključne riječi

ERPF; empirical model; single compartment kinetic model; solid-diffusion kinetic model

Hrčak ID:

197072

URI

https://hrcak.srce.hr/197072

Datum izdavanja:

1.12.1988.

Podaci na drugim jezicima: hrvatski

Posjeta: 896 *