CASE REPORT: PRE-TRANSPLANT TESTING AND POST-TRANSPLANT MONITORING FOR AN HLA-IMMUNIZED RECIPIENT IN HEART TRANSPLANTATION

Lucija Jukic ; Tissue Typing Centre, Clinical Department of Transfusion Medicine and Transplantation Biology, University Hospital Centre Zagreb, Zagreb, Croatia
Biserka Palfi ; Tissue Typing Centre, Clinical Department of Transfusion Medicine and Transplantation Biology, University Hospital Centre Zagreb, Zagreb, Croatia
Bosko Skoric ; Department for Cardiovascular Diseases, University Hospital Centre Zagreb, Zagreb, Zagreb, Croatia
Marija Burek Kamenaric ; Tissue Typing Centre, Clinical Department of Transfusion Medicine and Transplantation Biology, University Hospital Centre Zagreb, Zagreb, Croatia


Puni tekst: engleski pdf 435 Kb

str. 52-56

preuzimanja: 388

citiraj


Sažetak

We report the workflow of immunogenetic pre-transplant testing and post-transplant monitoring in the case of a recipient immunized to human leucocyte antigens (HLA) who was waitlisted for heart transplantation. The recipient underwent heart transplantation across preformed HLA class I Donor Specific Antibodies (DSAs) detected by solid phase Luminex screening method but not by complement dependent cytotoxicity (CDC) screening method. The CDC lymphocyte crossmatch, which was performed retrospectively, was a weak positive. Post-transplant DSA monitoring by Luminex method revealed the decrease of HLA-A1, A25 and B57 DSAs with, at the same time, an increase of HLA-B8 DSA, as well as weak transient non-DSA HLA-DP antibodies. This case presents the importance of extensive immunogenetic testing and monitoring for identifying recipients with increased immunological risk for successful heart transplantation.

Ključne riječi

immunogenetics; HLA antibodies; sensitization; DSA monitoring; heart transplantation

Hrčak ID:

238484

URI

https://hrcak.srce.hr/238484

Datum izdavanja:

1.6.2020.